[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646842-105":59,"doc-detail-646842-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","kidde-engineered-fire-suppression-system-pn-45-n1230m-001-design-installation-operation-and-maintenance-manual","Kidde Engineered Fire Suppression System - P/N 45-N1230M-001 - Design, Installation, Operation and Maintenance Manual","","Kidde Engineered Fire Suppression System manual describes the design, installation, operation, and maintenance of a system intended for use with 3M™ Novec™ 1230 Fire Protection Fluid. It instructs qualified, factory-trained personnel to follow NFPA and applicable standards, outlines responsibilities and disclaimers for system use, and emphasizes strict adherence to provided manuals and safety bulletins. It also supplies key terms and abbreviations and presents safety requirements for pressurized, safety-capped cylinder handling to prevent violent discharge, injury, death, and property damage.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/kidde-engineered-fire-suppression-system-pn-45-n1230m-001-design-installation-operation-and-maintenance-manual/646842/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/kidde-engineered-fire-suppression-system-pn-45-n1230m-001-design-installation-operation-and-maintenance-manual/646842.png","ImageObject",300,407,{"name":92,"@type":93},"McGucket","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who is this manual intended for and what standards must personnel follow?","Question",{"text":112,"@type":113},"The manual is for qualified, factory-trained personnel knowledgeable of NFPA and other applicable standards. It also emphasizes following the manuals and safety bulletins provided with the individual systems.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the key hazards associated with pressurized cylinders?",{"text":117,"@type":113},"Pressurized (charged) cylinders are extremely hazardous and can cause violent discharge if mishandled. This may result in serious injury, death, and property damage.",{"name":119,"@type":110,"acceptedAnswer":120},"What safety procedures must be observed when moving and storing cylinders?",{"text":121,"@type":113},"Cylinders must be shipped upright and properly secured, not rolled, dragged, or slid, and a suitable handling device should be used. They must not be dropped or struck violently and should be stored upright and secured to prevent being knocked over.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646842,1792930959,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},1236954412713,"https://us-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","Kidde Engineered Fire Suppression System  \nDesigned for use with  \n3M™ Novec™ 1230 Fire Protection Fluid  \nDesign, Installation,  \nOperation and Maintenance Manual  \n R   \nLISTED  \nUL Listing File No. EX 4674  \nLISTED  \nUL Listing File No. EX 4674  \nFM  \nAPPROVED  \nFM Approvals Project ID 3020593  \nP/N 45-N1230M-001 February 2005  \nP/N 45-N1230M-001  \nFebruary 2005  \nKidde Engineered Fire Suppression System  \nDesigned for use with 3M™ Novec™ 1230 Fire Protection Fluid  \nDesign, Installation, Operation and Maintenance Manual  \nTHIS PAGE INTENTIONALLY LEFT BLANK.  \nFOREWORD  \nNote: This Manual, P/N 45-N1230M-001, is to be used by qualified and factory-trained personnel, knowledgeable of NFPA standards and any other applicable standards in effect.  \nThis manual is intended to clearly and accurately reflect the Kidde Engineered Fire Suppression System designed for use with 3M™ Novec™ 1230 Fire Protection Fluid. This publication describes the operation, installation and maintenance of the system .  \nKidde-Fenwal assumes no responsibility for the application of any systems other than those addressed in this manual. The technical data contained herein is limited strictly for informational purposes only. KiddeFenwal believes this data to be accurate, but it is published and presented without any guarantee or warranty whatsoever. Kidde-Fenwal disclaims any liability for any use that may be made of the data and information contained herein by any and all other parties.  \nAny questions concerning the information presented in this manual should be addressed to: Kidde-Fenwal, Inc.  \n400 Main Street Ashland, MA 01721 Phone: (508) 881-2000  \nToll Free: (800) 872-6527  \nFax: (508) 881-8920  \nTERMS AND ABBREVIATIONS  \nADA:  \nAH:  \nAWG:  \nCO2:  \nDC:  \nFM:  \nH20  \nHVAC:  \nHz:  \nmA:  \nAmericans with Disabilities Act Ampere Hour  \nAmerican Wire Gauge Carbon Dioxide Direct Current  \nFM Approvals  \nWater  \nHeating, Venting and Air Conditioning Hertz (Frequency) Milliamperes  \nN.C. : NFPA:  \nN.O. : P/N: UL/ULI: ULC:  \nV:  \nVac:  \nVdc:  \nNormally Closed  \nNational Fire Protection Association  \nNormally Open Part Number  \nUnderwriters Laboratories, Inc.  \nUnderwriters Laboratories of Canada  \nVolts  \nVolts AC  \nVolts DC  \nTHIS PAGE INTENTIONALLY LEFT BLANK.  \nSAFETY SUMMARY  \nKidde Engineered Systems use pressurized equipment; therefore, personnel responsible for fire suppression systems must be aware of the dangers associated with the improper handling, installation or maintenance of this equipment.  \nFire suppression system service personnel must be thoroughly trained in the proper handling, installation and service of Kidde Engineered System equipment and follow the instructions used in this manual and in the Safety Bulletin.  \nKidde has provided warnings and cautions at appropriate locations throughout the text of this manual. These warnings and cautions are to be adhered to at all times . Failure to do so may result in serious injury to personnel.  \nSAFETY BULLETIN 1, MARCH 2, 1987  \nSUBJECT: SAFE CYLINDER HANDLING PROCEDURES  \nWARNING  \nPressurized (charged) cylinders are extremely hazardous and if not handled properly are capable of violent discharge. This may result in serious bodily injury, death and property damage.  \nBefore handling Kidde system products, all personnel must be thoroughly trained in the safe handling of the cylinders as well as in the proper procedures for installation, removal, filling, and connection of other critical devices, such as flex hoses, control heads, discharge heads, and anti-recoil devices.  \nREAD, UNDERSTAND and ALWAYS FOLLOW the operation and maintenance manuals, owners manuals, service manuals, etc., that are provided with the individual systems.  \nThe following safety procedures must be observed at all times:  \nMoving Cylinders: Cylinders must be shipped compactly in the upright position, and properly secured in place . Cylinders must not be rolled, dragged or slid, nor allowed to be slid from tailgates of v","cbCaiiiD1HsE1Dca","https://ap.wps.com/l/cbCaiiiD1HsE1Dca","pdf",1088073,156,"English","# Foreword\n# Terms and Abbreviations\n# Safety Summary\n# Safety Bulletin 1 (March 2, 1987)\n## Subject: Safe Cylinder Handling Procedures\n# Safety Bulletin (May 1, 1993)\n## Subject: Safe Cylinder Handling Procedures for Pressurized Cylinders","[{\"question\":\"Who is this manual intended for and what standards must personnel follow?\",\"answer\":\"The manual is for qualified, factory-trained personnel knowledgeable of NFPA and other applicable standards. It also emphasizes following the manuals and safety bulletins provided with the individual systems.\"},{\"question\":\"What are the key hazards associated with pressurized cylinders?\",\"answer\":\"Pressurized (charged) cylinders are extremely hazardous and can cause violent discharge if mishandled. This may result in serious injury, death, and property damage.\"},{\"question\":\"What safety procedures must be observed when moving and storing cylinders?\",\"answer\":\"Cylinders must be shipped upright and properly secured, not rolled, dragged, or slid, and a suitable handling device should be used. They must not be dropped or struck violently and should be stored upright and secured to prevent being knocked over.\"}]","Kidde Engineered Fire Suppression System - P/N 45-N1230M-001 - Design, Installation, Operation and Maintenance Manual | PDF",1792771459,393]