[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-665200-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-665200-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","key-resin-company-standard-flooring-design-details-guide-joint-details","KEY RESIN COMPANY - STANDARD FLOORING DESIGN DETAILS GUIDE - Joint Details","","Standard flooring design detail drawings for Key Resin Company, providing linked reference details for slab-on-grade vapor barriers and multiple joint conditions, including contraction/control, expansion/isolation, construction/cold, and buried control/crack treatments. The guide specifies resinous flooring terminations and transitions, covers epoxy terrazzo and carpet/VCT terminations, and includes drain, trench, cove, stair, and pipe penetration detail references with associated drawing identifiers for consistent installation.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/key-resin-company-standard-flooring-design-details-guide-joint-details/665200/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/key-resin-company-standard-flooring-design-details-guide-joint-details/665200.png","ImageObject",300,407,{"name":42,"@type":43},"ahduag","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",5,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What flooring conditions are covered by the vapor barrier detail?","Question",{"text":63,"@type":64},"The guide includes a detail specifically for a vapor barrier for slab on grade, intended to control moisture movement beneath the flooring system.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"Which joint types are documented in the standard flooring design details?",{"text":68,"@type":64},"It documents contraction/control joints, expansion/isolation joints, and construction/cold joints, with additional references for buried control joint and crack treatment.",{"name":70,"@type":61,"acceptedAnswer":71},"What types of resinous flooring terminations and transitions are referenced?",{"text":72,"@type":64},"The table of contents lists epoxy flooring and epoxy terrazzo terminations, including carpet/VCT termination, key-in termination, and related transition and termination details for specific installations.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},665200,1793292867,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":55,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":80,"read_time":144},3985747870414,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","|  |  |  |  |\n| --- | --- | --- | --- |\n| | 4050 Clough Woods Drive Batavia, Ohio 45103 888 943 4532\u003Cbr>[www.keyresin](www.keyresin) com |  | DETAIL: |\n|  |  | DATE: | FILE \\#: |\n\n\n| \u003Cbr>KEY RESIN COMPANY\u003Cbr>STANDARD FLOORING DESIGN DETAILS GUIDE |  |  |  | Click to link directly to the design detail of your choice. |\n| --- | --- | --- | --- | --- |\n| \u003Cbr>VAPOR BARRIER FOR SLAB ON GRADE KEY-DTL-1\u003Cbr>CONTRACTION/CONTROL JOINT KEY-DTL-2\u003Cbr>EXPANSION/ISOLATION JOINT KEY-DTL-3\u003Cbr>CONSTRUCTION/COLD JOINT KEY-DTL-4\u003Cbr>BURIED CONTROL JOINT/CRACK TREATMENT KEY-DTL-5\u003Cbr>EPOXY TERRAZZO-CARPET/VCT TERMINATION KEY-DTL-6\u003Cbr>EPOXY FLOORING KEY-IN TERMINATION KEY-DTL-7\u003Cbr>EPOXY FLOORING STEPS OVER CONCRETE KEY-DTL-8\u003Cbr>EPOXY FLOORING OVER CEMENT/EPOXY FILL KEY-DTL-9\u003Cbr>FLANGED DRAIN DETAIL KEY-DTL-10\u003Cbr>TRENCH DETAIL KEY-DTL-11\u003Cbr>COVE DETAIL \\#1 KEY-DTL-12\u003Cbr>COVE DETAIL \\#2 KEY-DTL-13\u003Cbr>COVE DETAIL \\#3 – RESINOUS FLOOR KEY-DTL-14\u003Cbr>CONTROL JOINT – RESINOUS FLOOR KEY-DTL-15\u003Cbr>PRECAST TERRAZZO THRESHOLD KEY-DTL-16\u003Cbr>TERRAZZO STEP TERMINATION DETAIL KEY-DTL-17\u003Cbr>RISER TREAD DETAIL KEY-DTL-18\u003Cbr>PRECAST EPOXY TERRAZZO COVE BASE KEY-DTL-19\u003Cbr>SPECIAL JOINT DETAILS – RESINOUS FLOOR KEY-DTL-20\u003Cbr>COVE DETAIL \\#4 KEY-DTL-21\u003Cbr>RESINOUS STAIR NOSING DETAIL KEY-DTL-23\u003Cbr>RISER TREAD DETAIL KEY-DTL-24\u003Cbr>COVE DETAIL \\#5 – RESINOUS FLOOR KEY-DTL-25\u003Cbr>SAW CUT EXPANSION JOINT – RS FLR KEY-DTL-26\u003Cbr>COVE DETAIL \\#6 – 8” RESINOUS COVE KEY-DTL-27\u003Cbr>RESINOUS FLOOR/CARPET TILE TERMINATION KEY-DTL-28\u003Cbr>CANT COVE DETAIL – RESINOUS FLOOR KEY-DTL-29\u003Cbr>ABRASIVE NON-SLIP LINES KEY-DTL-30\u003Cbr>COVE DETAIL – RESINOUS FLOOR/WALL KEY-DTL-31\u003Cbr>JOINT TREATMENT – WOOD/CEMENT BOARD KEY-DTL-32\u003Cbr>RESINOUS FLOOR/CERAMIC TILE TERMINATION KEY-DTL-33\u003Cbr>COVE DETAIL \\#7 – OVER EXPANSION JOINT KEY-DTL-34\u003Cbr>COVE DETAIL \\#8 – RESINOUS W/ STRIPS KEY-DTL-35\u003Cbr>TERRAZZO OVERLAY TRANSITION KEY-DTL-36\u003Cbr>PIPE PENETRATION DETAIL KEY-DTL-37 |  |  |  |  |\n|  |  |  |  |  |\n|  | 4050 Clough Woods Drive Batavia, Ohio 45103 888-943-4532\u003Cbr>[www.keyresin.com](www.keyresin.com) |  | DETAIL: TABLE OF CONTENTS – PG 1 OF 2 |  |\n|  |  | DATE:\u003Cbr>03/31/17 | FILE \\#: KEY RESIN FLOORING DETAIL DWGS |  |\n\n|  |  |  |  |\n| --- | --- | --- | --- |\n| | 4050 Clough Woods Drive Batavia, Ohio 45103 888 943 4532\u003Cbr>[www.keyresin](www.keyresin) com |  | DETAIL: |\n|  |  | DATE: | FILE \\#: |\n\n\n| \u003Cbr>KEY RESIN COMPANY\u003Cbr>STANDARD FLOORING DESIGN DETAILS GUIDE |  |  |  | Click to link directly to the design detail of your choice. |\n| --- | --- | --- | --- | --- |\n| \u003Cbr>COVE BASE ON STAINLESS STEEL TYPICAL MRI SUITE FLOORING DETAIL KEY CONDUCTIVE EPOXY TERRAZZO COVE DETAIL \\#9 – INTEGRAL WITH IMP COVE DETAIL \\#10 – CANT WITH IMP COVE DETAIL \\#11 – TILE WALL \\#1 COVE DETAIL \\#12 – TILE WALL \\#2 FLANGED DRAIN WATERPROOFING RESINOUS FLOORING TERMINATION PIPE PENETRATION DETAIL \\#2 STRIPLESS\u003Cbr>EXPANSION JOINT DETAIL KEY\u003Cbr>KEY-DTL-38\u003Cbr>KEY-DTL-39\u003Cbr>KEY-DTL-40\u003Cbr>KEY-DTL-42\u003Cbr>KEY-DTL-42\u003Cbr>KEY-DTL-43\u003Cbr>KEY-DTL-44\u003Cbr>KEY-DTL-45\u003Cbr>KEY-DTL-46\u003Cbr>KEY-DTL-47\u003Cbr>KEY-DTL-48 |  |  |  |  |\n|  | 4050 Clough Woods Drive Batavia, Ohio 45103 888-943-4532\u003Cbr>[www.keyresin.com](www.keyresin.com) |  | DETAIL: TABLE OF CONTENTS – PG 2 OF 2 |  |\n|  |  | DATE:\u003Cbr>03/31/17 | FILE \\#: KEY RESIN FLOORING DETAIL DWGS |  |\n\n\n| Click For Table of Contents\u003Cbr>NOTE:\u003Cbr>DO NOT PLACE 2”OF SAND OVER VAPOR BARRIER REFERENCE ACI-302 . IR-04 |  |  |  |\n| --- | --- | --- | --- |\n| EXTERIOR WALL\u003Cbr>\u003Cbr>|  |  |  |\n| | 4050 Clough Woods Drive Batavia, Ohio 45103 888-943-4532\u003Cbr>[www.keyresin.com](www.keyresin.com) | NOT TO\u003Cbr>SCALE | DETAIL: VAPOR BARRIER FOR SLAB ON GRADE |\n|  |  | DATE:\u003Cbr>2/24/08 | FILE \\#:\u003Cbr>KEY-DTL-1 |\n\n\n| Click For Table of Contents\u003Cbr>CONTRACTION/\u003Cbr>CONTROL JOINT |  |  |  |  |\n| --- | --- | --- | --- | --- |\n| KEY \\#780 FLEXIBLE EPOXY\u003Cbr>EPOXY ADHESIVE FULL LENGTH OF STRIP\u003Cbr>FILL SAW CUT JOINT WITH KEY CRACK FILLER \\#715\u003Cbr>(OR APPROVED 100% SOLIDS RIGID EPOXY) |  | PREFERRED ALTERNATE |  |  |\n|  |  | \u003Cbr>\u003Cbr>\u003Cbr>\u003Cb","cbCaieUP9nNDz4FV","https://ap.wps.com/l/cbCaieUP9nNDz4FV","pdf",1838553,49,"English","# Vapor Barrier for Slab on Grade\n# Joint Details\n## Contraction/Control Joint\n## Expansion/Isolation Joint\n## Construction/Cold Joint\n## Buried Control Joint/Crack Treatment\n# Cove and Termination Details\n## Cove Detail #1\n## Cove Detail #2\n## Cove Detail #3 – Resinous Floor\n## Control Joint – Resinous Floor\n# Drain, Trench, and Penetrations\n## Flanged Drain Detail\n## Trench Detail\n## Pipe Penetration Detail","[{\"question\":\"What flooring conditions are covered by the vapor barrier detail?\",\"answer\":\"The guide includes a detail specifically for a vapor barrier for slab on grade, intended to control moisture movement beneath the flooring system.\"},{\"question\":\"Which joint types are documented in the standard flooring design details?\",\"answer\":\"It documents contraction/control joints, expansion/isolation joints, and construction/cold joints, with additional references for buried control joint and crack treatment.\"},{\"question\":\"What types of resinous flooring terminations and transitions are referenced?\",\"answer\":\"The table of contents lists epoxy flooring and epoxy terrazzo terminations, including carpet/VCT termination, key-in termination, and related transition and termination details for specific installations.\"}]","KEY RESIN COMPANY - STANDARD FLOORING DESIGN DETAILS GUIDE - Joint Details | PDF",123]