[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-665073-105":59,"doc-detail-665073-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","kendal-power-station-30-year-ash-disposal-facility-maximum-continuous-dump-option-list-of-drawings","KENDAL POWER STATION - 30 YEAR ASH DISPOSAL FACILITY - MAXIMUM CONTINUOUS DUMP OPTION - LIST OF DRAWINGS","","A drawing index for KENDAL POWER STATION’s 30-year ash disposal facility, covering maximum continuous dump option planning. The list enumerates drawing numbers and titles, including site development planning and general arrangement. It also includes site layout studies for wetlands, electrical diversions, and road diversions, plus proposed new services. Additional entries cover leachate and sub-soil collection systems, pollution control dams (Dam 1 through Dam 7), ash disposal facility typical details, emergency dump layout, conveyor route, and typical road crossing details.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/kendal-power-station-30-year-ash-disposal-facility-maximum-continuous-dump-option-list-of-drawings/665073/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/kendal-power-station-30-year-ash-disposal-facility-maximum-continuous-dump-option-list-of-drawings/665073.png","ImageObject",300,407,{"name":92,"@type":93},"Obex","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What does the document list?","Question",{"text":112,"@type":113},"It lists drawing numbers and drawing titles for KENDAL POWER STATION’s ash disposal facility scope.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which major site layout studies are included?",{"text":117,"@type":113},"Site layout entries include wetland study, electrical diversions, road diversions, and proposed new services.",{"name":119,"@type":110,"acceptedAnswer":120},"Does the document cover pollution control dams?",{"text":121,"@type":113},"Yes, it includes layout drawings for pollution control dams, labeled Dam 1 through Dam 7, along with additional dam sheet groupings.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},665073,1793287710,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":81},5909898192665,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","KENDAL POWER STATION  \n30 YEAR ASH DISPOSAL FACILITY  \nMAXIMUM CONTINUOUS DUMP OPTION  \nLIST OF DRAWINGS  \n\n| DRAWING NUMBER   | DRAWING TITLE   |\n| --- | --- |\n| 12935-01-01   |  |\n|  | SITE DEVELOPMENT PLAN   |\n| 12935-01-02  \u003Cbr>12935-01-03  \u003Cbr>12935-01-04  \u003Cbr>12935-01-05  \u003Cbr>12935-01-06  \u003Cbr>12935-01-07  \u003Cbr>12935-01-08  \u003Cbr>12935-01-09   | GENERAL ARRANGEMENT  \u003Cbr>SITE LAYOUT-WETLAND STUDY  \u003Cbr>SITE LAYOUT-ELECTRICAL DIVERSIONS  \u003Cbr>SITE LAYOUT-ROAD DIVERSIONS  \u003Cbr>SITE LAYOUT-PROPOSED NEW SERVICES  \u003Cbr>SITE LAYOUT-LEACHATE COLLECTION SYSTEM  \u003Cbr>SITE LAYOUT-SUB-SOIL COLLECTION SYSTEM  \u003Cbr>LAYOUT-POLLUTION CONTROL DAMS -DAM 1   |\n| 12935-01-10  \u003Cbr>12935-01-11  \u003Cbr>12935-01-12  \u003Cbr>12935-01-13  \u003Cbr>12935-01-14  \u003Cbr>12935-01-15  \u003Cbr>12935-01-16  \u003Cbr>12935-01-17  \u003Cbr>12935-01-18  \u003Cbr>12935-01-19   | LAYOUT—POLLUTION CONTROL DAMS-DAM 2  \u003Cbr>LAYOUT-POLLUTION CONTROL DAMS -DAM3 AND 4  \u003Cbr>LAYOUT-POLLUTION CONTROL DAMS-DAM 5 AND 6  \u003Cbr>LAYOUT-POLLUTION CONTROL DAMS-DAM 7  \u003Cbr>ASH DISPOSAL FACILITY—TYPICAL DETAILS -SHEET 1  \u003Cbr>ASH DISPOSAL FACILITY—TYPICAL DETAILS-SHEET 2  \u003Cbr>SILT TRAP-TYPICAL LAYOUT SECTIONS AND DETAILS   |\n|  | EMERGENCY DUMP-LAYOUT SECTIONS AND DETAILS  \u003Cbr>CONVEYOR ROUTE -PLAN AND LONGITUDINAL SECTION  \u003Cbr>TYPICAL ROAD CROSSING DETAILS   |\n| 12935-01-20  \u003Cbr>12935-01-21  \u003Cbr>12935-01-22  \u003Cbr>12935-01-23  \u003Cbr>12935-01-24   | GENERAL ARRANGEMENT OF COLLECTION CHANNELS   |\n|  | CHANNEL LONGITUDINAL SECTIONS-SHEET 1  \u003Cbr>CHANNEL LONGITUDINAL SECTIONS -SHEET 2  \u003Cbr>CHANNEL LONGITUDINAL SECTIONS -SHEET 3  \u003Cbr>CHANNEL LONGITUDINAL SECTIONS -SHEET 4   |\n| 12935-01-25  \u003Cbr>12935-01-26  \u003Cbr>12935-01-27   | CHANNEL LONGITUDINAL SECTIONS-SHEET 5  \u003Cbr>CHANNEL LONGITUDINAL SECTIONS-SHEET 6  \u003Cbr>CHANNEL LONGITUDINAL SECTIONS -SHEET 7   |\n| 12935-01-28  \u003Cbr>12935-01-29  \u003Cbr>12935-01-30   | CHANNEL LONGITUDINAL SECTIONS-SHEET 8  \u003Cbr>CHANNEL LONGITUDINAL SECTIONS -SHEET 9  \u003Cbr>CHANNEL LONGITUDINAL SECTIONS -SHEET 10   |\n| 12935-01-31  \u003Cbr>12935-01-32  \u003Cbr>12935-01-33  \u003Cbr>12935-01-34  \u003Cbr>12935-01-35   | CHANNEL LONGITUDINAL SECTIONS-SHEET 11  \u003Cbr>CHANNEL LONGITUDINAL SECTIONS -SHEET 12  \u003Cbr>CHANNEL LONGITUDINAL SECTIONS-SHEET 13  \u003Cbr>CHANNEL LONGITUDINAL SECTIONS-SHEET 14   |\n| 12935-01-36  \u003Cbr>12935-01-37   | CHANNEL LONGITUDINAL SECTIONS-SHEET 15  \u003Cbr>CHANNEL LONGITUDINAL SECTIONS-SHEET 16   |\n|  | CHANNEL LONGITUDINAL SECTIONS -SHEET 17   |\n| 12935-01-38   | LAYOUT OF TRANSNET PIPELINE DIVERSION  \u003Cbr>LONGITUDINAL SECTION OF TRANSNET PIPELINE DIVERSION-SHEET 1   |\n| 12935-01-39  \u003Cbr>12935-01-40  \u003Cbr>12935-01-41  \u003Cbr>12935-01-42   |  |\n|  | LONGITUDINAL SECTION OF TRANSNET PIPELINE DIVERSION-SHEET 2  \u003Cbr>LONGITUDINAL SECTION OF TRANSNET PIPELINE DIVERSION -SHEET3  \u003Cbr>LONGITUDINAL SECTION OF TRANSNET PIPELINE DIVERSION-SHEET 4   |","cbCaihzmD9J0S5Eu","https://ap.wps.com/l/cbCaihzmD9J0S5Eu","pdf",121012,"English","# DRAWING NUMBER\n## SITE DEVELOPMENT PLAN\n## GENERAL ARRANGEMENT\n## SITE LAYOUT - WETLAND STUDY\n## SITE LAYOUT - ELECTRICAL DIVERSIONS\n## SITE LAYOUT - ROAD DIVERSIONS\n## SITE LAYOUT - PROPOSED NEW SERVICES\n## SITE LAYOUT - LEACHATE COLLECTION SYSTEM\n## SITE LAYOUT - SUB-SOIL COLLECTION SYSTEM\n## LAYOUT - POLLUTION CONTROL DAMS","[{\"question\":\"What does the document list?\",\"answer\":\"It lists drawing numbers and drawing titles for KENDAL POWER STATION’s ash disposal facility scope.\"},{\"question\":\"Which major site layout studies are included?\",\"answer\":\"Site layout entries include wetland study, electrical diversions, road diversions, and proposed new services.\"},{\"question\":\"Does the document cover pollution control dams?\",\"answer\":\"Yes, it includes layout drawings for pollution control dams, labeled Dam 1 through Dam 7, along with additional dam sheet groupings.\"}]","KENDAL POWER STATION - 30 YEAR ASH DISPOSAL FACILITY - MAXIMUM CONTINUOUS DUMP OPTION - LIST OF DRAWINGS | PDF"]