[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646611-105":59,"doc-detail-646611-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","kbl-series-peristaltic-metering-pump-operation-and-maintenance-manual-version-42-september-2024","KBL-SERIES Peristaltic Metering Pump - Operation and Maintenance Manual - Version 4.2 - September-2024","","Operation and Maintenance Manual for the LMI KBL-series peristaltic metering pump, version 4.2 (September 2024). Covers how to use the manual, user training and instructions, handling and storage recommendations, pump specifications including operating temperature, humidity, altitude, electrical power, sound level, flow rate and pressure limits. Provides setup guidance via the installation and best-practice sections, then details operating modes such as manual, remote/SCADA, and batching/dosing, followed by maintenance and troubleshooting, plus agency compliance and warranty declarations.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/kbl-series-peristaltic-metering-pump-operation-and-maintenance-manual-version-42-september-2024/646611/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/kbl-series-peristaltic-metering-pump-operation-and-maintenance-manual-version-42-september-2024/646611.png","ImageObject",300,407,{"name":92,"@type":93},"Aria","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-24","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who must read and follow this maintenance manual, and how should temporary personnel be handled?","Question",{"text":112,"@type":113},"All persons who install, use, or perform maintenance operations must read the manual in its entirety. Temporary personnel must be supervised by skilled users, and the operation sequence defined in the manual must be respected.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What storage conditions are recommended for the KBL-series pumps and tube elements?",{"text":117,"@type":113},"Store pumps and accessories indoors in a dry environment with no exposure to UV light. Avoid storing pumps with tube elements installed and under compression, and use tube elements and accessories within two years of the manufacturing date.",{"name":119,"@type":110,"acceptedAnswer":120},"What operating modes are described for the pump?",{"text":121,"@type":113},"The manual describes Manual Mode and Remote Mode (including SCADA and industrial protocols such as Modbus RTU, Modbus TCP, and RS 485). It also includes Batch / Dose Mode with dosing and batching functions.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646611,1792855910,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},2336464648322,"https://ap-avatar.wpscdn.com/avatar/2200025388227c56fec?_k=1778556882303663488","Operation and Maintenance Manual  \nKBL-SERIES  \nPeristaltic Metering Pump / Operation and Maintenance Manual Version: 4.2  \nSeptember-2024  \nKBL-SERIES  \nTable of Contents  \n1 | INTRODUCTION  ..............................3  \n1.1-How to use this maintenance manual ...... 3  \n1.2-Training of the user and instructions ....... 3  \n1.3-Handling and Storage................... 3  \n1.4-Pump Specifications.................... 4  \n1.5-Nameplate Detail ...................... 4  \n1.6-Service Point information ................ 5  \n2 | MODEL DESCRIPTION CHART  ...................6  \n2.1-Model Code Explanation ................ 6  \n2.2-Materials Of Construction................ 7  \n2.3-Available Tube Assemblies ............... 8  \n2.3.1-Tube Assemblies Color Guide ........ 8  \n2.4-Dimensions ........................... 9  \n3 | OPERATING AND SAFETY PRECAUTIONS  ........ 10  \n3.1-Safety Symbol Identification ............. 10  \n3.2-Explanation Of Safety Signal Words ....... 10  \n3.3-Product Parts Information .............. 11  \n4 | INSTALLATION  .............................. 12  \n4.1-Power Requirements .................. 12  \n4.2-Control Wiring ........................ 12  \n4.2.1-I/O Board ....................... 13  \n4.3-Best Practices........................ 14  \n4.3-Pre Operation Checklist ................ 15  \n5 | GETTING STARTED  .......................... 16  \n5.1-User Interface ........................ 16  \n5.2-Understanding the display (Home Screen) .. 16  \n5.2.1-Home Screen .................... 16  \n5.3-Keypad ............................. 17  \n5.4-Icons ............................... 18  \n5.5-Quick Start Guide ..................... 20  \n6 | OPERATING MODES  .........................33  \n6.1-Manual Mode ........................ 33  \n6.2-Remote Mode ........................ 33  \n6.2.1-SCADA ........................ 33  \n6.2.2-Industrial protocols ............... 35  \n6.2.2.1-Modbus RTU ............... 36  \n6.2.2.2-Modbus TCP ............... 36  \n6.2.2.3-RS 485 .................... 37  \n6.2.3-Batch / Dose Mode ............... 37  \n6.2.3.1-Dosing .................... 37  \n6.2.3.2-Batching .................. 38  \n6.2.4-Batching ....................... 39  \n7 | MAINTENANCE  .............................40  \n7.1-Routine Inspection .................... 40  \n7.2-Tube Replacement .................... 40  \n7.3-Roller Assembly Replacement ........... 42  \n7.4-Spare Parts .......................... 43  \n8 | TROUBLESHOOTING  .........................47  \n8.1-Troubleshooting Guide ................. 47  \n9 | AGENCY & COMPLIANCE  ....................49  \n10 | WARRANTY DECLARATION  ...................50  \n10.1-Flush & Decontamination .............. 50  \n2 [lmi@irleads.com](lmi@irleads.com) 􀂄 [Lmipumps.com](Lmipumps.com) 􀂄 LMI KMB-Series Operation and Maintenance Manual  \n KBL-SERIES  \nIntroduction  \nThank you for purchasing an LMI KBL Peristaltic Metering Pump. Items supplied vary according to product configuration. Make sure that the items supplied and the information on the nameplate correspond to the order confirmation. Check the individual packaging and the product visually for damage caused by inappropriate handling during shipment. Contact your distributor immediately if any items are missing or damaged.  \nFor more information [please visit www.lmipumps.com](please visit www.lmipumps.com)  \n 1.1 | HOW TO USE THIS MAINTENANCE MANUAL  \nThis manual is specific to LMI PUMPS KBL series peristaltic pumps. It allows the users to install, to start and to carry out maintenance on these pumps. All persons, fitters and users must read this maintenance manual in its entirety. Documents concerning the gearbox, the electrical motors, as well as all other options (hose rupture detector, etc.) are provided in annex. Refer to the applicable section in this document to understand specific details regarding that component.  \nYour local LMI distributor can be contacted regarding information not contained in this manual. For a quicker reply, please provide the follo","cbCaiaWHZfpfIxIf","https://ap.wps.com/l/cbCaiaWHZfpfIxIf","pdf",7042085,52,"English","# INTRODUCTION\n## How to use this maintenance manual\n## Training of the user and instructions\n## Handling and Storage\n## Pump Specifications\n## Nameplate Detail\n## Service Point information\n# MODEL DESCRIPTION CHART\n## Model Code Explanation\n## Materials Of Construction\n## Available Tube Assemblies\n## Tube Assemblies Color Guide\n## Dimensions\n# OPERATING AND SAFETY PRECAUTIONS\n## Safety Symbol Identification\n## Explanation Of Safety Signal Words\n## Product Parts Information\n# INSTALLATION\n## Power Requirements\n## Control Wiring\n## I/O Board\n## Best Practices\n## Pre Operation Checklist\n# GETTING STARTED\n## User Interface\n## Understanding the display (Home Screen)\n## Home Screen\n## Keypad\n## Icons\n## Quick Start Guide\n# OPERATING MODES\n## Manual Mode\n## Remote Mode\n## SCADA\n## Industrial protocols\n## Modbus RTU\n## Modbus TCP\n## RS 485\n## Batch / Dose Mode\n## Dosing\n## Batching\n# MAINTENANCE\n## Routine Inspection\n## Tube Replacement\n## Roller Assembly Replacement\n## Spare Parts\n# TROUBLESHOOTING\n## Troubleshooting Guide\n# AGENCY & COMPLIANCE\n# WARRANTY DECLARATION\n## Flush & Decontamination","[{\"question\":\"Who must read and follow this maintenance manual, and how should temporary personnel be handled?\",\"answer\":\"All persons who install, use, or perform maintenance operations must read the manual in its entirety. Temporary personnel must be supervised by skilled users, and the operation sequence defined in the manual must be respected.\"},{\"question\":\"What storage conditions are recommended for the KBL-series pumps and tube elements?\",\"answer\":\"Store pumps and accessories indoors in a dry environment with no exposure to UV light. Avoid storing pumps with tube elements installed and under compression, and use tube elements and accessories within two years of the manufacturing date.\"},{\"question\":\"What operating modes are described for the pump?\",\"answer\":\"The manual describes Manual Mode and Remote Mode (including SCADA and industrial protocols such as Modbus RTU, Modbus TCP, and RS 485). It also includes Batch / Dose Mode with dosing and batching functions.\"}]","KBL-SERIES Peristaltic Metering Pump - Operation and Maintenance Manual - Version 4.2 - September-2024 | PDF",1792764655,131]