[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663311-105":59,"doc-detail-663311-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","kapiti-coast-district-council-private-drainage-as-built-drawing-specification","Kapiti Coast District Council - Private Drainage As-built Drawing Specification","","This document provides the mandatory specifications for submitting as-built drainage drawings to the Kapiti Coast District Council. It emphasizes the necessity of maintaining accurate records of all private drainage alterations, connections, and additions for legal and management compliance. The guide outlines essential requirements, including appropriate drawing scales, standardized title block information, and required site details such as property boundaries, fixed reference points, and specific plumbing features. By following these technical guidelines, drainlayers ensure that documentation is uniform, high-quality, and clearly legible for council records, thereby facilitating effective infrastructure management and future maintenance.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/kapiti-coast-district-council-private-drainage-as-built-drawing-specification/663311/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/kapiti-coast-district-council-private-drainage-as-built-drawing-specification/663311.png","ImageObject",300,407,{"name":92,"@type":93},"Obex","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-28",true,{"@type":101,"interactionType":102,"userInteractionCount":4},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What are the primary reasons for submitting as-built drainage drawings?","Question",{"text":111,"@type":112},"The council requires these drawings for legal reasons and to maintain best management practice records for all drainage alterations, amendments, or additions.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What is the required paper size for as-built drainage plans?",{"text":116,"@type":112},"Drawings should ideally be A3 size, though A4 is acceptable for minor works only.",{"name":118,"@type":109,"acceptedAnswer":119},"What details must be included in the title block of the plan?",{"text":120,"@type":112},"The title block must include the text “As-Laid Private Drainage Plan,” the address of the works, the name of the person who drew the plan, the date, and the Building Consent number.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},663311,1793226443,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":4,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":138,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":139,"faqs":140,"seo_title":141,"seo_description":67,"update_tm":128,"read_time":81},5909898192665,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","Kapiti Coast District Council Private Drainage As-built Drawing Specification The Council, for both legal and best management practice reasons, must obtain and maintain records of all alterations, amendments, connections , or additions to private drainage.  \nDesign, construction, and as-built documentation are integral components of meeting this requirement.  \n• Drawings must clearly and accurately show where the drains have been laid.  \n• Drawings must be uniform and of good quality.  \n• Drawings must be clearly presented, use a logical sequence of detail and contain all required measurements without being congested.  \n• Drawings must be sized and scaled to allow for all aspects, to ensure clarity and no loss of detail.  \nAs-built drainage plans must contain the following minimum information:  \n1. Drawing size A3 – or A4 for minor works only  \n2. Title Block  \n• “As-Laid Private Drainage Plan”  \n• Address of works  \n• Details of who has drawn plan and date  \n• Building Consent number  \n3. Notes  \n• Certifying Drainlayer’s details – Name & PGBD Registration number  \n• Date of laying – month and year  \n4. Plan  \n• Drawn to a scale of 1:100 (preferred)  \n• North point  \n• Property boundaries and road frontage to confirm orientation  \n• Fixed point of reference. Refer sketch below. X and Y  \n• Building outlines  \n• Laterals, plumbing features (gully traps, access points etc. ) and subsoil drains  \n• Connection public drainage networks  \nDrain  \nGT  \n1.2 deep  \nRoad Boundary  \nBuilding Outline  \nW/C X  \nS  \ni  \nd  \ne  \nB  \no  \nu  \nn  \nd  \na  \nr  \ny","cbCaigLBiWHHT4vZ","https://ap.wps.com/l/cbCaigLBiWHHT4vZ","pdf",173445,"English","# Drawing Standards\n## Minimum Information Requirements\n### Title Block Details\n### Notes and Certification\n### Plan Specifications","[{\"question\":\"What are the primary reasons for submitting as-built drainage drawings?\",\"answer\":\"The council requires these drawings for legal reasons and to maintain best management practice records for all drainage alterations, amendments, or additions.\"},{\"question\":\"What is the required paper size for as-built drainage plans?\",\"answer\":\"Drawings should ideally be A3 size, though A4 is acceptable for minor works only.\"},{\"question\":\"What details must be included in the title block of the plan?\",\"answer\":\"The title block must include the text “As-Laid Private Drainage Plan,” the address of the works, the name of the person who drew the plan, the date, and the Building Consent number.\"}]","Kapiti Coast District Council - Private Drainage As-built Drawing Specification | PDF"]