[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-676640-105":3,"detail-sidebar-cat-0-en-105":79,"doc-detail-676640-en":129},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":72,"head_meta":74,"extra_data":76,"updated_unix":78},105,"en","jurassic-park-arcade-operators-manual-power-safety-and-specifications","Jurassic Park Arcade - Operator’s Manual - Power, Safety, and Specifications","","Operator’s Manual for a Jurassic Park arcade cabinet, providing product specifications, electrical power requirements, and fuse ratings for RIO PCB, cabinet circuits, and audio power thermal protection. Includes operating safety guidance covering installation, transporting, handling sensitive and ESD-prone components, disconnecting and grounding practices, electrical shock hazards, monitor high-voltage warnings, and cautions about water damage. Also specifies allowed temperature and humidity ranges plus cabinet dimensions, and lists distributor/contact information for sales, technical support, warranty, and repair.",{"@graph":14,"@context":71},[15,34,54],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/jurassic-park-arcade-operators-manual-power-safety-and-specifications/676640/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":48,"encodingFormat":47,"isAccessibleForFree":49,"interactionStatistic":50},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/jurassic-park-arcade-operators-manual-power-safety-and-specifications/676640.png","ImageObject",300,407,{"name":42,"@type":43},"Cart","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-04",true,{"@type":51,"interactionType":52,"userInteractionCount":22},"InteractionCounter",{"@type":53},"ViewAction",{"@type":55,"mainEntity":56},"FAQPage",[57,63,67],{"name":58,"@type":59,"acceptedAnswer":60},"What electrical power inputs does the cabinet support?","Question",{"text":61,"@type":62},"The manual lists domestic 120 VAC @ 60 Hz (5 amps), international 240 VAC @ 50 Hz (2.5 amps), and Japan 100 VAC @ 50 Hz (5 amps).","Answer",{"name":64,"@type":59,"acceptedAnswer":65},"What fuse ratings are specified for the RIO PCB?",{"text":66,"@type":62},"It specifies +5 VDC - 3 amp slow blow and +12 VDC - 5 amp slow blow, with additional guidance that audio power uses a thermal fuse and that the RIO F3 is part of the audio fuse reference.",{"name":68,"@type":59,"acceptedAnswer":69},"What safety steps must be followed before servicing or adjustments?",{"text":70,"@type":62},"Always turn off power and unplug the unit before servicing unless otherwise instructed, ensure proper grounding with a grounded three-wire outlet, and be aware that lethal voltages can remain in electronic components and the monitor even when power is off.","https://schema.org",{"og:url":32,"og:type":73,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":75,"canonical":32},"index,follow",{"doc_id":77,"site_id":7},676640,1793776324,{"code":4,"msg":80,"data":81},"success",[82,86,90,94,99,103,108,113,118,121,125],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":83,"show_sort_weight":84,"slug":85},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":87,"show_sort_weight":88,"slug":89},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":91,"show_sort_weight":92,"slug":93},"Exam",70,"exam",{"id":95,"doc_module":4,"doc_module_name":25,"category_name":96,"show_sort_weight":97,"slug":98},5,"Comic",60,"comic",{"id":100,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":101,"slug":102},6,50,"technology",{"id":104,"doc_module":4,"doc_module_name":25,"category_name":105,"show_sort_weight":106,"slug":107},7,"Healthcare",40,"healthcare",{"id":109,"doc_module":4,"doc_module_name":25,"category_name":110,"show_sort_weight":111,"slug":112},8,"Research & Report",30,"research-report",{"id":114,"doc_module":4,"doc_module_name":25,"category_name":115,"show_sort_weight":116,"slug":117},9,"Religion & Spirituality",20,"religion-spirituality",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":119,"show_sort_weight":116,"slug":120},"World Cup","world-cup",{"id":122,"doc_module":4,"doc_module_name":25,"category_name":123,"show_sort_weight":122,"slug":124},10,"Lifestyle","lifestyle",{"id":126,"doc_module":4,"doc_module_name":25,"category_name":127,"show_sort_weight":95,"slug":128},19,"General","general",{"code":4,"msg":80,"data":130},{"doc_id":77,"user_id":131,"nickname":42,"user_avatar":132,"doc_module":4,"category_id":100,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":22,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":138,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":78,"read_time":143},18829141979164,"https://eur-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","You can get [this game at www.magic-play.eu](this game at www.magic-play.eu)  \nPN: 040‐00044‐01 16‐ Jan  \nOPERATOR’S MANUAL  \nYou can get [this game at www.magic-play.eu](this game at www.magic-play.eu)  \nYou can get [this game at www.magic-play.eu](this game at www.magic-play.eu)  \nOperator’s Manual  \nProduct Specifications  \nElectrical Power  \nDomestic 120 VAC @ 60 Hz, 5 amps International 240 VAC @ 50 Hz, 2.5 amps  \nJapan 100 VAC @ 50 Hz, 5 amps  \nDC Power Fuse Guide  \nELECTICAL SAFETY NOTICE: REPLACE FUSE WITH SPECIFIED FUSE RATING ONLY. DO NOT REPLACE FUSE WITH HIGHER THAN SPECIFIED RATING.  \nRIO PCB FUSE GUIDE:  \n+5 VDC ‐ 3 amp Slow Blow (RIO MCU, START BUTTON)  \n+12 VDC ‐ 5 amp Slow Blow (COIN DOOR, COOLING FANS, DASH LED)*+12 VDC ‐ AUDIO POWER USES A THERMAL FUSE, RIO F3  \nCABINET FUSE GUIDE:  \n(NOTE: FUSES ARE MOUNTED TO THE LEFT OF THE RIO PCB. F1 IS LOCATED CLOSEST RIO PCB)  \nF1 ‐ PLAYER 1 GUN SOLENOID POWER , 5 amp Slow Blow  \nF2 ‐ PLAYER 2 GUN SOLENOID POWER , 5 amp Slow Blow F3 ‐ DINO HEAD BACKLIGHT, 5 amp Slow Blow  \nF4 ‐ JURASSIC PARK GATE LOGO, 5 amp Slow Blow F5 ‐ ROOF LED LED T‐MOLD, 5 amp Slow Blow F6 ‐ BENCH LED T‐MOLD, 5 amp Slow Blow  \nTemperature  \n32° to 100° Fahrenheit (0° to 38° Celsius)  \nHumidity  \nMust not exceed 95% relative humidity or where visible condensation is present.  \nCabinet Dimensions  \n\n| Component | Height | Width | Depth |\n| --- | --- | --- | --- |\n| Assembled 55”Environmental Model | 118 in. / 300 cm | 53.5 in. / 136 cm | 80 in. / 203 cm |\n\nJurassic Park ™© is a trademark and copyright of Universal Studios and Amblin Entertainment, Inc. Licensed by Universal Studios Licensing LLC. All rights reserved. Jurassic Park Arcade Game Software Copyright 2014 Raw Thrills, Inc. All rights reserved.  \nPage | 2  \nYou can get [this game at www.magic-play.eu](this game at www.magic-play.eu)  \nYou can get [this game at www.magic-play.eu](this game at www.magic-play.eu)  \nOperator’s Manual  \nContact Information  \nFor an authorized distributor near you, check the Raw Thrills website [at](at www. rawthrills.com)[ ](at www. rawthrills.com)[www. rawthrills.com](at www. rawthrills.com)  \nContact Betson Enterprise Headquarters or your local Betson office for sales, technical information, warranty or repair. Betson can be reached at (800) 524‐2343 Fax (201) [438‐4837](438‐4837 www.betson.com)[ ](438‐4837 www.betson.com)[www.betson.com](438‐4837 www.betson.com)  \nBetson Enterprises Headquarters  \n303 Paterson Plank Rd.  \nCarlstadt, NJ 07072  \n(800) 524‐2343 or (201) 438‐1300 fax (201) 438‐4837  \n\u003CJP environmental cabinet image>  \nJurassic Park ™© is a trademark and copyright of Universal Studios and Amblin Entertainment, Inc. Licensed by Universal Studios Licensing LLC. All rights reserved. Jurassic Park Arcade Game Software Copyright 2014 Raw Thrills, Inc. All rights reserved.  \nPage | 3  \nYou can get [this game at www.magic-play.eu](this game at www.magic-play.eu)  \nYou can get [this game at www.magic-play.eu](this game at www.magic-play.eu)  \nOperator’s Manual  \nSafety  \nOPERATION  \nBefore operating game, read this manual. Failure to properly install and operate this game could result in malfunction or accident. Operate the game in accordance with the manual.  \nTRANSPORTING  \nCabinet is very heavy and contains fragile components. Use appropriate care when moving or transporting cabinet. Avoid rough handling.  \nHANDLING COMPONENTS  \nMany components are extremely sensitive to handling, environmental and Electrostatic Discharge (ESD) events—especially the computer. Do not handle it roughly. Before servicing, call your distributor and inquire about the PC warranty. Use proper ESD procedures when servicing. Protect components from harmful environmental conditions, such as extreme temperatures, excessive moisture or other damaging effects.  \nDISCONNECT POWER  \nAlways turn off power and unplug the unit before servicing or making adjustments, unless otherwise instructed. Installing or repairing components whil","cbCaikko1wq6eeAu","https://ap.wps.com/l/cbCaikko1wq6eeAu","pdf",11876150,36,"English","# Product Specifications\n## Electrical Power\n## DC Power Fuse Guide\n## Temperature and Humidity\n## Cabinet Dimensions\n# Safety\n## Operation\n## Transporting\n## Handling Components and ESD\n## Disconnect Power and Grounding\n## Electrical Shocks and Monitor Warnings\n## Power Selector and Connectors\n# Contact Information","[{\"question\":\"What electrical power inputs does the cabinet support?\",\"answer\":\"The manual lists domestic 120 VAC @ 60 Hz (5 amps), international 240 VAC @ 50 Hz (2.5 amps), and Japan 100 VAC @ 50 Hz (5 amps).\"},{\"question\":\"What fuse ratings are specified for the RIO PCB?\",\"answer\":\"It specifies +5 VDC - 3 amp slow blow and +12 VDC - 5 amp slow blow, with additional guidance that audio power uses a thermal fuse and that the RIO F3 is part of the audio fuse reference.\"},{\"question\":\"What safety steps must be followed before servicing or adjustments?\",\"answer\":\"Always turn off power and unplug the unit before servicing unless otherwise instructed, ensure proper grounding with a grounded three-wire outlet, and be aware that lethal voltages can remain in electronic components and the monitor even when power is off.\"}]","Jurassic Park Arcade - Operator’s Manual - Power, Safety, and Specifications | PDF",91]