[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-664001-105":59,"doc-detail-664001-en":133},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":126,"head_meta":128,"extra_data":130,"updated_unix":132},105,"en","jsc-board-batten-weatherboard-cladding-20-mm-cavity-on-rigid-underlay-technical-drawings-version-12","JSC Board & Batten Weatherboard Cladding - 20 mm Cavity on Rigid Underlay - Technical Drawings Version 1.2","","Technical drawings set for JSC Board & Batten weatherboard cladding using a 20 mm cavity on rigid underlay, version 1.2 dated 12/02/2024. Provides an index of sectional and detail views, including plan and cross-section guidance, bottom and top plate details, corners, junctions, parapet, meterbox interfaces, pipe penetrations, and window details. Includes cavity batten setout rules (e.g., end gaps), fixing requirements with specified nails, pre-drilling, penetration and spacing limits, slope direction, coating notes, and references to NZBC/E2 and NZS 3604.",{"@graph":69,"@context":125},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/jsc-board-batten-weatherboard-cladding-20-mm-cavity-on-rigid-underlay-technical-drawings-version-12/664001/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/jsc-board-batten-weatherboard-cladding-20-mm-cavity-on-rigid-underlay-technical-drawings-version-12/664001.png","ImageObject",300,407,{"name":92,"@type":93},"notyourbestiee","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29",true,{"@type":101,"interactionType":102,"userInteractionCount":19},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117,121],{"name":108,"@type":109,"acceptedAnswer":110},"What is the purpose of the 20 mm cavity setout guide in these drawings?","Question",{"text":111,"@type":112},"It specifies how to set out and fix the 45x20 mm cavity battens horizontally, including required gaps between batten ends/sides and detailing considerations for different wall conditions.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"How should the cavity battens be fixed and what are the key nail requirements?",{"text":116,"@type":112},"The drawings specify single fixing at each nog using annular grooved stainless steel or silicon bronze nails, including pre-drilling guidance, minimum nail penetration into framing, maximum centers, and an upward slope during fixing where applicable.",{"name":118,"@type":109,"acceptedAnswer":119},"What coating and underlay requirements are included for the board and batten weatherboard system?",{"text":120,"@type":112},"The system is to be coated with an approved suitable coating to all four sides and ends, while the rigid wall underlay must comply with NZBC/E2 Table 23 (installed to manufacturer specifications).",{"name":122,"@type":109,"acceptedAnswer":123},"Which detail sections are provided for corners, junctions, and windows?",{"text":124,"@type":112},"The index includes internal and external corner details, inter storey junction and parapet details, plus window head, jamb, and sill details (JVB-R20-30, JVB-R20-31, JVB-R20-32).","https://schema.org",{"og:url":83,"og:type":127,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":129,"canonical":83},"index,follow",{"doc_id":131,"site_id":62},664001,1793236178,{"code":4,"msg":5,"data":134},{"doc_id":131,"user_id":135,"nickname":92,"user_avatar":136,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":137,"file_id":138,"file_url":139,"file_type":140,"file_size":141,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":142,"language":143,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":144,"faqs":145,"seo_title":146,"seo_description":67,"update_tm":132,"read_time":147},962094243716,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","TECHN ICA L DRAWINGS  \nJSC Board & Batten  \nBoard and Batten Weatherboard Cladding 20 mm Cavity on Rigid Underlay  \nVersion 1.2 | 12/02/2024  \nIndex  \n20mm Cavity Setout Guide Fixed Horizontally JVB‐R20‐SEC01 Sectional Detail – Plan View  \nJVB‐R20‐SEC02 Sectional Detail – Cross Section View JVB‐R20‐01 Bottom Plate Detail  \nJVB‐R20‐01A Bottom Plate on Timber Detail  \nJVB‐R20‐02 Top Plate Soffit Detail JVB‐R20‐03 Raking Soffit Detail JVB‐R20‐04 Bottom Plate Soffit Detail JVB‐R20‐05 Inter Storey Junction Detail JVB‐R20‐06 Parapet Detail  \nJVB‐R20‐10 Internal Corner Detail JVB‐R20‐12 External Corner Box Detail JVB‐R20‐20 Scarf Detail  \nJVB‐R20‐21 Pipe Penetration Detail JVB‐R20‐25 Meterbox Head Detail JVB‐R20‐26 Meterbox Jamb Detail  \nJVB‐R20‐27 Meterbox Sill Detail JVB‐R20‐30 Window Head Detail JVB‐R20‐31 Window Jamb Detail  \nJVB‐R20‐32 Window Sill Detail  \n20mm Cavity Batten Setout fixed Horizontally  \nJSC-U 45x20mm Timber Cavity Batten  \n(/)  \n0)  \nC  \n('Cl  \n3:  \n0  \nen  \ng'  \nx  \n('Cl  \nE  \n-  \n(/)  \n􀀉  \n....  \nC  \n􀀊  \nE E  \nZ 0-co  \ns::t  \n©)  \nCorner Flashing  \nNote: This setout guide is for fixing JSC-U 45x20 mm Cavity Battens for Vertical weatherboard cladding  \nPlan View  \n10mm gap between cavity battens ends or sides  \nInterior lining or use rigid wall underlay for unlined walls such as gable ends. See NZBC/E2 paragraph 9.1.4  \nFlexible or Rigid wall underlay to comply with NZBC/E2 Table 23 installed to manufacturers specifications  \nSingle fix at each nog with annular grooved stainless steel or silicon bronze nails as per NZBC/E2 Table 24  \n· Pre-drilled 1mm diameter smaller than nail gauge  \n· Nailed with a 2º upward slope  \n· 30mm min penetration into framing  \n· Nailed at the center of the board or batten at max 480 centers  \nJSC-U H3 .2 45x20mm treated timber castellated cavity batten  \n· Tacked on with SS Clout or similar  \n· 10mm gab between cavity battens  \n· Always slope down away from wall  \nJSC Board and Batten Weatherboard  \n· Coated with approved suitable coating to all 4 sides and ends  \n· 40-50mm Stainless steel clout to hold in place the cavity battens prior to board installation  \nFraming to NZS 3604 or \"fit for purpose\"  \nNote: To be read in conjunction with complete JSC installation instructions · Details may be subject to change without notification  \n\n| Sectional Detail -Rigid Underlay | JVB-20-SEC01 | Scale: 1:2\u003Cbr>Date: 12/02/2024 |\n| --- | --- | --- |\n\nEmail:  \nWeb:  \n[TechHelp@jsctimber.co.nz](TechHelp@jsctimber.co.nz)[ ](TechHelp@jsctimber.co.nz)[www.jsctimber.co.nz](www.jsctimber.co.nz)  \nAuckland  \n20 Sawmill Road Riverhead  \n􀂫 09 412 2800  \nChristchurch  \n72 Hammersmith Drive Wigram  \n􀂫 03 348 9726  \nCross Section View  \n| \u003Cbr>|\n| --- |\n|  |\n\n15°  \nStuds @600mm max . centers  \nBatten used horizontally as a filler or packer with a 15° bevel on the top edge sloping away from wall  \nJSC-U H3 .2 45x20mm treated timber castellated cavity batten  \n· Tacked on with SS Clout or similar  \n· Keep 10mm gap to the cavity battens except at bottom plate  \n· Cut ends to slope away from wall (10-15°)  \nFlexible or Rigid wall underlay to comply with NZBC/E2 Table 23 installed to manufacturers specifications  \nInterior lining or use rigid wall underlay for unlined walls such as gable ends. See NZBC/E2 Paragraph 9.1.4  \nJ120 or J121 coated with approved coating on all 4 sides  \nJ123 or J124 coated with approved coating on all 4 sides  \nSingle fix at each nog with annular grooved stainless steel or silicon bronze nails as per NZBC/E2 Table 24  \n· Pre-drilled 1mm diameter smaller than nail gauge  \n· Nailed with a 2º upward slope  \n· 30mm min penetration into framing  \n· Nailed at the center of the board or batten at max 480mm centers  \nFraming to NZS 3604 or \"fit for purpose\"  \nNote: To be read in conjunction with complete JSC installation instructions · Details may be subject to change without notification  \n\n| Sectional Detail -Rigid Underlay | JVB-20-SEC02 | Scale: 1:2\u003Cbr>Date: 12/02/2024 |\n| --- | --- | --- ","cbCaioLBpWSQv5E8","https://ap.wps.com/l/cbCaioLBpWSQv5E8","pdf",2930359,23,"English","# 20mm Cavity Setout Guide\n## Fixed Horizontally\n# Sectional Detail - Rigid Underlay\n## Plan View (JVB-R20-SEC01)\n## Cross Section View (JVB-R20-SEC02)\n# Bottom Plate Detail (JVB-R20-01)\n## Bottom Plate on Timber (JVB-R20-01A)\n# Top Plate and Soffit Details\n## Top Plate Soffit (JVB-R20-02)\n## Raking Soffit (JVB-R20-03)\n# Bottom Plate and Junction Details\n## Bottom Plate (JVB-R20-04)\n## Inter Storey Junction (JVB-R20-05)\n## Parapet (JVB-R20-06)\n# Corner and Interface Details\n## Internal Corner (JVB-R20-10)\n## External Corner Box (JVB-R20-12)\n## Scarf (JVB-R20-20)\n# Penetrations and Meterbox Details\n## Pipe Penetration (JVB-R20-21)\n## Meterbox Head (JVB-R20-25)\n## Meterbox (JVB-R20-26)\n## Meterbox Jamb (JVB-R20-26)\n## Meterbox Sill (JVB-R20-27)\n# Window and Framing Notes\n## Window Head (JVB-R20-30)\n## Window Jamb (JVB-R20-31)\n## Window Sill (JVB-R20-32)","[{\"question\":\"What is the purpose of the 20 mm cavity setout guide in these drawings?\",\"answer\":\"It specifies how to set out and fix the 45x20 mm cavity battens horizontally, including required gaps between batten ends/sides and detailing considerations for different wall conditions.\"},{\"question\":\"How should the cavity battens be fixed and what are the key nail requirements?\",\"answer\":\"The drawings specify single fixing at each nog using annular grooved stainless steel or silicon bronze nails, including pre-drilling guidance, minimum nail penetration into framing, maximum centers, and an upward slope during fixing where applicable.\"},{\"question\":\"What coating and underlay requirements are included for the board and batten weatherboard system?\",\"answer\":\"The system is to be coated with an approved suitable coating to all four sides and ends, while the rigid wall underlay must comply with NZBC/E2 Table 23 (installed to manufacturer specifications).\"},{\"question\":\"Which detail sections are provided for corners, junctions, and windows?\",\"answer\":\"The index includes internal and external corner details, inter storey junction and parapet details, plus window head, jamb, and sill details (JVB-R20-30, JVB-R20-31, JVB-R20-32).\"}]","JSC Board & Batten Weatherboard Cladding - 20 mm Cavity on Rigid Underlay - Technical Drawings Version 1.2 | PDF",58]