[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-319649-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-319649-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","journeyman-electrician-practice-exam-part-12","Journeyman Electrician Practice Exam - Part 12","","Journeyman Electrician Practice Exam #12 provides 22 multiple-choice questions aligned with the 2014 National Electrical Code. The exam covers hospital-grade receptacles and patient bed locations, neutral conductor rules, garage receptacle requirements for central vacuum systems, GFCI/AFCI/LCDI protection choices, and various cable and wiring limitations. It also tests emergency standby transfer switches, maximum temperatures for specific fixture wire types, burial depths, marking for electric flash hazards, demand load calculations, and transformer full-load current ratings.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/exam/","Exam",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/journeyman-electrician-practice-exam-part-12/319649/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/journeyman-electrician-practice-exam-part-12/319649.png","ImageObject",300,407,{"name":42,"@type":43},"Margaret","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-08","2026-09-20",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",10,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What exam content does Journeyman Electrician Practice Exam #12 cover?","Question",{"text":63,"@type":64},"The questions are based on the 2014 edition of the National Electrical Code and reflect typical items found on Journeyman Electricians’ exams.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How long is allotted time for this practice exam?",{"text":68,"@type":64},"The allotted time is 75 minutes.",{"name":70,"@type":61,"acceptedAnswer":71},"What types of topics are included in the questions?",{"text":72,"@type":64},"The exam includes receptacle and protection requirements (GFCI/AFCI/LCDI), cable type limitations, emergency standby and transfer switch rules, sizing/calculation questions, and equipment marking for flash hazards.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},319649,1790099384,{"code":4,"msg":82,"data":83},"success",[84,88,92,95,100,105,110,115,120,123,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":93,"slug":94},70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":112,"show_sort_weight":113,"slug":114},8,"Research & Report",30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":55,"slug":125},"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":33,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":55,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":144,"preview_page_count":4},137451207643,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","JOURNEYMAN ELECTRICIANPractice Exam\\#12  \nThe following questions are based on the 2014 edition of the National Electrical Code@and aretypical of questions encountered on most Journeyman Electricians'Exams.Select the best answerfrom the choices given and review your answers with the answer key included in this book.  \nALLOTTED TIME:75 minutes  \nNotes  \nJourneyman ElectricianPractice Exam\\#12  \n1.Each patient bed location in the general care areas of a hospitalor similar health care facility shall be provided with a MINIMUMof      125-volt,single-phase,15-or 20-ampere listed \"hospitalgrade”receptacles.  \nA.8  \nB.6  \nC.10  \nD.14  \n2.A neutral conductor is always    \nA.a grounded conductor  \nB.an ungrounded conductor  \nC.white in color  \nD.the conductor connected to the neutral point of a systemthat is intended to carry current under normal conditions  \n3.Where a single 125-volt,single-phase,20-ampere receptacleoutlet located in an attached garage of a dwelling unit isprovided for a central vacuum assembly,the receptacle outletis required to have      \nA.AFCl protection  \nB.GFCl protection  \nC.LCDI protection  \nD.a nonmetallic faceplate  \n4.All 240-volt,twist-lock,30-ampere receptacles located on aconstruction site,where supplied from a temporary service,are required to have    when not covered by an assuredgrounding program.  \nA.weatherproof covers  \nB.LCDI protection  \nC.GFCl protection  \nD.AFCl protection  \n5.When a service disconnecting means consists of two or threesingle-pole switches or breakers capable of individual operation,and supplying multiwire circuits,this method of installation is incompliance with the NEC®where the      \nA.devices are listed  \nB.devices are indicating  \nC.switches or breakers are linked together using a galvanizednail or other galvanized metal object  \nD.switches or breakers are equipped with identifiedhandle ties  \n# 6.Type AC cable shallbe permitted  \n\nA.for feeders  \nB.in wet locations  \nC.where exposed to corrosive conditions  \nD.in damp locations  \n7.An approved method of protection for equipment installed inClass I,Zone 0,hazardous locations is      \nA.purged and pressurized  \nB.encapsulation  \nC.powder filling  \nD.oil immersion  \n# 8.Type NM cable is NOT permitted for use    \n\nA.in Type V construction  \nB.in wet locations  \nC.for exposed work in dry locations  \nD.in any of the above listed installations  \nNotes  \nNotes  \n# 9.The MAXIMUM operating temperature for thermoplastic-coveredsolid fixture wire,Type TFF,is  F.\n\nA.60  \nB.75  \nC.90  \nD.140  \n10.Raceways approved for burial only,where concrete encased,shallrequire a concrete envelope NOT less than    inches thick.  \nA.2  \nB.3  \nC.4  \nD.6  \n11.In regard to emergency and legally required standby systems,transfer switches shall be      and approved by the authorityhaving jurisdiction.  \nA.manual  \nB.automatic  \nC.non-automatic  \nD.red in color  \n12.Transfer equipment of optional standby systems shall besuitable for the intended use and designed and installed so asto prevent the inadvertent interconnection of    sources ofsupply in any operation of the transfer equipment.  \nA.AC and DC  \nB.primary and secondary  \nC.input and output  \nD.normal and alternate  \n13.In general,a general-use fused switch used as a disconnectingmeans for a 25 hp,480-volt,three-phase AC motor with anFLA of 32 amperes indicated on the nameplate must have anampere rating of at LEAST  amperes.  \nA.39  \nB.50  \nC.56  \nD.79  \n14.When a size 8/3 AWG with ground copper NM cable is installedin the attic of a dwelling unit where the ambient temperaturereaches 130°F during the summer months,the conductors havea MAXIMUM allowable ampacity of    amperes.  \nA.40.0  \nB.41.8  \nC.33.5  \nD.16.4  \n15.In regard to new outdoor installations of permanently installedswimming pools,luminaires installed above the pool or within5 feet horizontally from the inside wall of the pool shall be installedat a height NOT less than    feet above the maximum waterlevel of the pool.  \nA.10  \nB.12  \nC","cbCaiv3Ye0y4Lt3S","https://ap.wps.com/l/cbCaiv3Ye0y4Lt3S","pdf",3418179,"English","# Questions\n## Multiple-choice items (1–22)\n## Notes and exam instructions","[{\"question\":\"What exam content does Journeyman Electrician Practice Exam #12 cover?\",\"answer\":\"The questions are based on the 2014 edition of the National Electrical Code and reflect typical items found on Journeyman Electricians’ exams.\"},{\"question\":\"How long is allotted time for this practice exam?\",\"answer\":\"The allotted time is 75 minutes.\"},{\"question\":\"What types of topics are included in the questions?\",\"answer\":\"The exam includes receptacle and protection requirements (GFCI/AFCI/LCDI), cable type limitations, emergency standby and transfer switch rules, sizing/calculation questions, and equipment marking for flash hazards.\"}]","Journeyman Electrician Practice Exam - Part 12 | PDF",1789946055,25]