[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-436629-105":59,"doc-detail-436629-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","journeyman-electrician-practice-exam-10","JOURNEYMAN ELECTRICIAN Practice Exam - #10","","Journeyman Electrician Practice Exam #10 provides timed, multiple-choice questions based on the 2014 National Electrical Code. It challenges examinees on conduit and enclosure installation requirements, surge-protective device connections, wiring methods, grounding electrode sizing, and limits for voltage drop. The exam also tests safety clearances for luminaires, hazardous-location boundaries, emergency electrical system branch classifications, conductor sizing and types, and calculations of full-load current for multi-phase services. Detailed notes and an answer-key review process support self-assessment.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":20,"@type":76,"position":81},"https://docshare.wps.com/document/exam/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/journeyman-electrician-practice-exam-10/436629/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/journeyman-electrician-practice-exam-10/436629.png","ImageObject",300,407,{"name":92,"@type":93},"AfterMidnight","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-09","2026-09-29",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What reference code does Practice Exam #10 use?","Question",{"text":112,"@type":113},"The questions are based on the 2014 edition of the National Electrical Code (NEC).","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How much time is allotted for the exam?",{"text":117,"@type":113},"The allotted time is 75 minutes.",{"name":119,"@type":110,"acceptedAnswer":120},"How are questions structured and how should answers be checked?",{"text":121,"@type":113},"Each item is multiple-choice; select the best answer from the choices given and review answers with the answer key included in the book.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},436629,1790904561,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":19,"category_name":20,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":52,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},962090896061,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","# JOURNEYMAN ELECTRICIANPractice Exam\\#10\n\nThe following questions are based on the 2014 edition of the National Electrical Code⑧and are typicalof questions encountered on most Journeyman Electricians'Exams.Select the best answer fromchoices given and review your answers with the answer key included in this book.  \nALLOTTED TIME:75 minutes  \nJourneyman ElectricianPractice Exam\\#10  \nNotes  \n1.Where conduits enter a floor-standing switchboard,switchgear,or panelboard at the bottom,the conduits,including their endfittings,shall NOT rise more than    inches above the bottomof the enclosure.  \nA.6  \nB.4  \nC.2  \nD.3  \n2.When installed on the service of a building or structure,a Type 2SPD shall be connected        \nA.on the line side of the service disconnect overcurrent device  \nB.on the load side of the service disconnect overcurrentdevice  \nC.on the meter housing  \nD.at the final overcurrent device  \n3.A detached garage supplied from a dwelling with a three-wirefeeder of size 4/0 AWG aluminum USE cable with a 200-ampererated circuit breaker for overcurrent protection requires aMINIMUM size copper grounding electrode to a concrete encasedelectrode of   AWG.  \nA.8  \nB.6  \nC.4  \nD.2  \n4.When a raceway is run through the wall from the interior to theexterior of a building,the raceway shall    \nA.be rigid metal conduit(RMC)  \nB.be rigid polyvinyl chloride conduit(PVC)  \nC.be sealed with an approved material  \nD.have an explosion-proof seal  \n5.Floor-mounted Type FCC cable shall be covered with carpetNotessquares NOT larger than    inches squared.  \nA.18.75  \nB.24.50  \nC.36.00  \nD.39.37  \n6.Where an 80-ampere,240-volt,single-phase load is located200 feet from the panelboard and is supplied with size 3 AWGcopper conductors with THHN/THWN insulation,what is theapproximate voltage-drop on this circuit?(K=12.9)  \nA.6.0 volts  \nB.4.0 volts  \nC.9.2 volts  \nD.7.84 volts  \n7.Enclosures in a ClassI,Division 1,location containing componentsthat have arcing devices must have an approved seal located withinat LEAST      inches of each conduit run entering or leaving suchenclosures.  \nA.12  \nB.18  \nC.24  \nD.30  \n8.Surface-mounted incandescent luminaires installed on the wallabove the door or on the ceiling of a clothes closet shall have aclearance of at LEAST  inches between the luminaire and thenearest point of closet storage space.  \nA.6  \nB.8  \nC.18  \nD.12  \n9.The NEC®considers the area around the outdoor motor fueldispensing pumps at aservice station to be a hazardous location.This area extends a height of 18 inches above grade,and upto a distance from the enclosure of the fuel dispensing pump offeet.  \nNotes  \nA.5  \nB.10  \nC.16  \nD.20  \n10.According to the NEC®,what are the three(3)mandatory branchesof the hospital essential emergency electrical system?  \nA.emergency branch,standby branch,and critical branch  \nB.life safety branch,critical branch,and equipment branch  \nC.normal branch,alternate branch,and optional standbybranch  \nD.emergency branch,non-essential branch,and normalbranch  \n11.Class 3 single-conductors,used as other wiring within buildings,shall NOT be smaller than   AWG and shall be Type CL3.  \nA.18  \nB.16  \nC.14  \nD.20  \n12.Where an office building has a 208Y/120-volt,three-phaseservice with a balanced net computed load of 90 kVA,what isthe current each ungrounded (phase)conductor carries at fullload?  \nA.188 amperes  \nB.250 amperes  \nC.433 amperes  \nD.750 amperes  \n13.When grounding the structural reinforcing steel of a swimmingpool,what is the SMALLEST size grounding conductor permittedfor this installation?  \nA.12 AWG  \nB.10 AWG  \nC.8 AWG  \nD.6AWG  \n14.A surge-protective device (SPD)is a protective device for      \nA.limiting transient voltage by diverting or limiting surgecurrent  \nB.limiting transient voltage by absorbing and storing excessivesurge current  \nC.switching transient voltage back to the line side of theservice transformer  \nD.none of these  \n15.Storage batteries used as a source of power for emergencysystems s","cbCairNz41hFtgAd","https://ap.wps.com/l/cbCairNz41hFtgAd","pdf",3460403,"English","# Practice Exam\n## Questions 1-21","[{\"question\":\"What reference code does Practice Exam #10 use?\",\"answer\":\"The questions are based on the 2014 edition of the National Electrical Code (NEC).\"},{\"question\":\"How much time is allotted for the exam?\",\"answer\":\"The allotted time is 75 minutes.\"},{\"question\":\"How are questions structured and how should answers be checked?\",\"answer\":\"Each item is multiple-choice; select the best answer from the choices given and review answers with the answer key included in the book.\"}]","JOURNEYMAN ELECTRICIAN Practice Exam - #10 | PDF",1790678599,25]