[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-401945-105":59,"doc-detail-401945-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","journeyman-electrician-final-exam-instructions-and-sample-questions","Journeyman Electrician - Final Exam - Instructions and Sample Questions","","Journeyman Electrician Final Exam provides NEC®-based exam instructions and a set of multiple-choice questions covering electrical installation rules. It specifies the passing score, total number of questions, points per question, and allotted time. The questions address topics such as fuse sizing for motor protection, conductor identification, cable adjustment factors, receptacle placement for show window lighting, equipment connection requirements, ampacity correction under sunlight, wiring and termination temperature ratings, grounding electrode rules, service-drop clearance, and raceway permissions for specific fire pump wiring uses.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":20,"@type":76,"position":81},"https://docshare.wps.com/document/exam/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/journeyman-electrician-final-exam-instructions-and-sample-questions/401945/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/journeyman-electrician-final-exam-instructions-and-sample-questions/401945.png","ImageObject",300,407,{"name":92,"@type":93},"Valentina","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-08","2026-09-27",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",16,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What is the passing score and how many questions are on the exam?","Question",{"text":113,"@type":114},"The passing score is 70%. The exam consists of 100 questions, each worth 1.0 point.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How long is the exam allotted time?",{"text":118,"@type":114},"The allotted time is 5 hours.",{"name":120,"@type":111,"acceptedAnswer":121},"What is required to pass the exam if a candidate does not reach the passing score?",{"text":122,"@type":114},"If you do not score at least 70%, try again and keep studying.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},401945,1790584529,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":19,"category_name":20,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":4},13056703020460,"https://ap-avatar.wpscdn.com/avatar/be000253dac470eee5d?_k=1778207105932848923","# JOURNEYMAN ELECTRICIANFinal Exam\n\nThe following questions are based on the 2014 edition of the National Electrical Code@and are typicalof questions encountered on most Journeyman Electricians'Exams.Select the best answer from thechoices given and review your answers with the answer key included in this book.Passing score onthis exam is 70%.The exam consists of 100 questions valued at 1.0 point each,so you must answerat least 70 questions correct for a passing score.If you do not score at least 70%,try again and keepstudying.GOOD LUCK.  \nALLOTTED TIME:5 hours  \n# Journeyman ElectricianFinal Exam\n\nNotes  \n1.When determining the initial standard size time-delay fuses forbranch-circuit,short-circuit,and ground-fault protection for athree-phase,continuous-duty,squirrel cage,AC motor,the fusesshall have a rating of    percent of the FLC of the motor.Whenthe value determined does not correspond to a standard ampererating,the next higher standard rating shall be permitted.  \nA.175  \nB.150  \nC.225  \nD.250  \n2.In compliance with the NEC®,a conductor with three (3)white orgray stripes on a black background is permitted to be used as a(n)   conductor.  \nA.ungrounded  \nB.grounding  \nC.grounded  \nD.hot-phase  \n3.An installation consisting of seven (7)non-jacketed size 12 AWGType MC cables,each with three (3)current-carrying conductorsbundled together longer than 24 inches shall have an adjustmentfactor of      percent.  \nA.45  \nB.50  \nC.60  \nD.70  \n4.All 125-volt,single-phase,15-or 20-ampere receptacle outletsinstalled for show window lighting in commercial occupanciesshall be located within at LEAST    inches of the top of theshow window to be served.  \nA.18  \nB.24  \nC.30  \nD.12  \n5.When wiring gasoline fuel dispensing pumps,the first fitting thatshould be installed in the raceway that emerges from below groundor concrete into the base of the gasoline fuel dispenser is a(n)      \nA.automatic cut-off breakaway valve  \nB.disconnect  \nC.sealing fitting  \nD.no fittings of any kind are permitted in this location  \n6.One kVA is equal to    \nA.100 watts  \nB.1,000 volt-amps  \nC.100 kilo-watts  \nD.100 volt-amps  \n7.When determining the allowable ampacity of conductors wherethe conductors or cables are installed in raceways exposed todirect sunlight four (4)inches above a rooftop,    F shall beadded to the expected ambient outdoor temperature to determinethe applicable correction factors of NEC⑧Table 310.15(B)(16).  \nA.60  \nB.40  \nC.30  \nD.25  \n8.Heavy-duty lighting track is lighting track identified for useEXCEEDING        \nA.15 amperes  \nB.600 watts  \nC.20 amperes  \nD.120 volts  \nNotes  \n9.In general,NPT threaded entries into explosion-proof equipmentshall be made up with at LEAST  threads fully engaged.  \nNotes  \nA.4  \nB.5  \nC.5/2  \nD.6  \n10.Live parts of generators operated at MORE than    voltsto ground shall not be exposed to accidental contact whereaccessible to unqualified persons.  \nA.24  \nB.50  \nC.120  \nD.150  \n11.Unless listed and identified otherwise,terminations and conductorsof circuits rated 100 amperes or larger shall be rated at    ℃.  \nA.60  \nB.75  \nC.90  \nD.120  \n12.In general,all mechanical elements used to terminate a groundingelectrode conductor or bonding jumper to a grounding electrodeshall be accessible.Which of the following,if any,is/are anexception(s)to this rule?  \nI.a connection to concrete-encased electrode  \nIl.a compression connection to fire-proofed structural metal  \nA.lonly  \nB.ll only  \nC.both Iand l  \nD.neither I nor ll  \n13.In regard to service-drop conductors of 0-750 volts to ground,a clearance of NOT less than   feet shall be maintainedbetween the maximum water level of a swimming pool and theservice-drop conductors.  \nNotes  \nA.10  \nB.14/2  \nC.19  \nD.2212  \n14.When a galvanized eye-bolt is to be used as the point ofattachment for the overhead service conductors to a building orother structure,the NEC⑧requires the eye-bolt to be installedNOT less than      feet above finished grade.  \nA.8  \nB.12  \nC.10  \nD","cbCainSdz3OeY3JA","https://ap.wps.com/l/cbCainSdz3OeY3JA","pdf",12271376,34,"English","# Exam Instructions\n# Notes\n## Question Set 1\n## Question Set 2","[{\"question\":\"What is the passing score and how many questions are on the exam?\",\"answer\":\"The passing score is 70%. The exam consists of 100 questions, each worth 1.0 point.\"},{\"question\":\"How long is the exam allotted time?\",\"answer\":\"The allotted time is 5 hours.\"},{\"question\":\"What is required to pass the exam if a candidate does not reach the passing score?\",\"answer\":\"If you do not score at least 70%, try again and keep studying.\"}]","Journeyman Electrician - Final Exam - Instructions and Sample Questions | PDF",1790525430,86]