[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-657481-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-657481-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","isoiec-170252017-transition-an-overview-of-the-changes-between-170252005-and-170252017","ISO/IEC 17025:2017 Transition - An Overview of the Changes between 17025:2005 and 17025:2017","","ISO/IEC 17025:2017 Transition booklet explains how labs should approach the transition from ISO/IEC 17025:2005 to ISO/IEC 17025:2017, created by Perry Johnson Laboratory Accreditation, Inc. It outlines why accreditation supports efficient, technically competent calibration and testing, and how the new standard aligns more closely with ISO 9001:2015. Key changes include risk-based thinking, option A and B management system approaches, added definitions, and updated structural, resource, and process requirements.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/isoiec-170252017-transition-an-overview-of-the-changes-between-170252005-and-170252017/657481/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/isoiec-170252017-transition-an-overview-of-the-changes-between-170252005-and-170252017/657481.png","ImageObject",300,407,{"name":42,"@type":43},"OKfine","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-26",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",5,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the purpose of implementing an ISO/IEC 17025 laboratory management system?","Question",{"text":63,"@type":64},"It ensures efficiency and technical competency in calibration and testing laboratories. Accreditation signals that the laboratory values quality and produces accurate, reliable results.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How does ISO/IEC 17025:2017 differ from ISO/IEC 17025:2005?",{"text":68,"@type":64},"The 2017 revision introduces risk-based thinking and reduces former prescriptive requirements in favor of performance-based requirements, allowing more flexibility in documented information and responsibilities.",{"name":70,"@type":61,"acceptedAnswer":71},"What do Option A and Option B mean in the ISO/IEC 17025:2017 standard?",{"text":72,"@type":64},"They are management system approaches introduced in 2017, primarily hinging on whether laboratories are established in compliance with ISO 9001:2015.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},657481,1793041701,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,100,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":55,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145},962093957596,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","ISO/IEC 17025:2017 Transition  \nAn Overview of the Changes between 17025:2005 and 17025:2017  \nPerry Johnson Laboratory Accreditation, Inc.  \n755 West Big Beaver Road, Suite 1325 • Troy, MI 48084  \n1-877-369-LABS • [www.pjlabs.com](www.pjlabs.com)  \nCopyright © 2019 by Perry Johnson Laboratory Accreditation, Inc. All rights reserved. No part of this book may be reproduced in any form, or by any means, without permission in writing from Perry Johnson Laboratory Accreditation, Inc. Publication Date: 2/26/2019 .  \nISO/IEC 17025:2017 Transition  \nTable of Contents  \nForeword .......................................................................................................................................2  \nISO/IEC 17025 Transition.................................................................................................................2  \nThe Main Changes ..........................................................................................................................3  \nStructure ...........................................................................................................................3  \nTerms and Definitions – 9 Definitions added .......................................................................3  \nISO 9001 Principles .............................................................................................................4  \nInformation Technology .....................................................................................................4  \nManagement System – Option A vs. Option B .....................................................................4  \nGeneral Requirements |Section 4| ..................................................................................................5  \nImpartiality ........................................................................................................................5  \nConfidentiality ...................................................................................................................5  \nStructural Requirements |Section 5| ..............................................................................................6  \nResource Requirements |Section 6| ...............................................................................................7  \nGeneral ....................................................................................................................................7  \nPersonnel ................................................................................................................................7  \nFacilities and Environmental .....................................................................................................7  \nEquipment ...............................................................................................................................8  \nMetrological Traceability ..........................................................................................................8  \nExternally Provided Products and Services ................................................................................8  \nProcess Requirements |Section 7| ..................................................................................................9  \nManagement System Requirements |Section 8| ........................................................................... 13  \nAbout Perry Johnson Laboratory Accreditation, Inc...................................................................... 17  \nISO/IEC 17025:2017 Transition Perry Johnson Laboratory Accreditation, Inc. Page 1 of 17  \nForeword  \nImplementing an ISO/IEC 17025 laboratory management system is a means to ensuring efficiency and technical competency in calibration and testing laboratories. An ISO/IEC 17025 accreditation certificate will show potential customers that your laboratory values quality and that you have taken the steps to ensure that your calibration or testing results are accurate and reliable.  \nISO","cbCairo2j4UYyWS4","https://ap.wps.com/l/cbCairo2j4UYyWS4","pdf",1700257,18,"English","# Foreword\n# ISO/IEC 17025 Transition\n## The Main Changes\n## Structure\n## Terms and Definitions – 9 Definitions added\n## ISO 9001 Principles\n## Information Technology\n## Management System – Option A vs. Option B\n## General Requirements |Section 4|\n## Impartiality\n## Confidentiality\n## Structural Requirements |Section 5|\n## Resource Requirements |Section 6|\n## General\n## Personnel\n## Facilities and Environmental\n## Equipment\n## Metrological Traceability\n## Externally Provided Products and Services\n## Process Requirements |Section 7|\n## Management System Requirements |Section 8|\n# About Perry Johnson Laboratory Accreditation, Inc.","[{\"question\":\"What is the purpose of implementing an ISO/IEC 17025 laboratory management system?\",\"answer\":\"It ensures efficiency and technical competency in calibration and testing laboratories. Accreditation signals that the laboratory values quality and produces accurate, reliable results.\"},{\"question\":\"How does ISO/IEC 17025:2017 differ from ISO/IEC 17025:2005?\",\"answer\":\"The 2017 revision introduces risk-based thinking and reduces former prescriptive requirements in favor of performance-based requirements, allowing more flexibility in documented information and responsibilities.\"},{\"question\":\"What do Option A and Option B mean in the ISO/IEC 17025:2017 standard?\",\"answer\":\"They are management system approaches introduced in 2017, primarily hinging on whether laboratories are established in compliance with ISO 9001:2015.\"}]","ISO/IEC 17025:2017 Transition - An Overview of the Changes between 17025:2005 and 17025:2017 | PDF",1792980697,45]