[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-645754-105":59,"doc-detail-645754-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","iron-core-linear-motor-manual-ver-20-installation-and-operation-guide","Iron core linear motor manual -ver. 2.0 - Installation and operation guide","","Iron core linear motor manual version 2.0 provides guidance for technicians assembling machines that include Tecnotion’s iron core linear motor systems. It explains intended use as a permanent magnet direct drive motor for linear motion, outlines important safety remarks, handling requirements for sensitive magnet plates, and key installation considerations. The manual also covers motor components, configuration options, electrical connections, pre-commissioning and startup, plus appendices with dimensions, coupling, cable configuration, sensor locations, package weight, and F/v graphs.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/iron-core-linear-motor-manual-ver-20-installation-and-operation-guide/645754/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/iron-core-linear-motor-manual-ver-20-installation-and-operation-guide/645754.png","ImageObject",300,407,{"name":92,"@type":93},"Quinn Holloway","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-23",true,{"@type":101,"interactionType":102,"userInteractionCount":4},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What is the intended use of the Tecnotion iron core linear motor system?","Question",{"text":111,"@type":112},"It is intended for wherever linear motion along an axis is required. It is designed as a permanent magnet direct drive motor and must be used only as intended, since other uses are not warranted.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What safety precautions are important before installing the linear motor?",{"text":116,"@type":112},"Read the instruction manual carefully and follow the provided requirements. Magnet plates have strong attraction forces and can cause serious jamming danger, so soft magnetic objects must not be brought closer than 25 centimeters.",{"name":118,"@type":109,"acceptedAnswer":119},"How should the magnet plates be handled and protected during installation?",{"text":120,"@type":112},"Handle components with care both packed and unpacked. Avoid mechanical shocks: never drop a magnet plate or release it uncontrolled. Do not expose magnets to temperatures higher than 70°C to prevent demagnetization.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},645754,1792734068,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":4,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":138,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":128,"read_time":143},2336474466712,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","Iron core linear motor manual  \nversion 2. 0  \nIron core l inear motor manual -ver. 2.0  \nINTRODUCTION  \nA linear motor system is part of a speci c machine. Tecnotion’s iron core linear motors are components that can be combined with numerous application devices. This manual is intended for technicians who want to construct a machine that includes a linear motor system. It gives insight in the basic components of a Tecnotion iron core linear motor and additional components to complete the whole motion system. The manual further informs about important design and installation aspects of the linear motors, the important dimensions for designing the construction that will hold the linear motor, the required settings before starting up, and other aspects. Also, it will give insight in the de nition of all speci cations of a Tecnotion linear motor.  \nWhen installing a linear motor system, one should be familiar with some important safety remarks. In the rst chapter these remarks are made. Please read them carefully. For technical questions you can contact the Application Engineering department at [support@tecnotion.com](support@tecnotion.com) or at +31 546 898 475.  \nIINTRODUCTION 2  \nIron core l inear motor manual -ver. 2.0  \nTABLE OF CONTENTS  \n1. BEFORE YOU START 5  \n1.1 Important notices 5  \n1.2 Safety warnings 5  \n1.3 Certi cation 6  \n1.3.1 CE certi cation  \n1.3.2 RoHS certi cation  \n1.3.3 ISO certi cation  \n1.3.4 CSA certi cation  \n1.3.5 REACH certi cation  \n1.3.6 TSCA certi cation  \n1.3.7 UKCA certi cation  \n1.3.8 Con􀀞ict mineral regulation  \n1.3.9 China compulsory certi cate  \n2. MOTOR COMPONENTS 8  \n2.1 Basic components 8  \n2.1.1 Coil unit  \n2.1.2 Magnet plates  \n2.1.3 Magnetic eld protection plates  \n2.2 Additional parts 10  \n3. MOTOR CONFIGURATION 12  \n3.1 Con guration options 12  \n3.1.1 Magnet track length  \n3.1.2 Coupling of motors  \n3.1.3 Air gap and mounting height  \n3.2 Heat transfer 15  \n4. INSTALLATION 16  \n4.1 Cleaning 16  \n4.2 Installation 16  \n4.2.1 Requirements for the mounting surface  \n4.2.2 Coil unit mounting  \n4.2.3 Magnet plate mounting  \n4.2.4 Water cooling installation  \n4.3 Electrical connections  \n4.3.1 General remarks  \n4.3.2 Power wires  \n4.3.3 Voltage spikes  \n4.3.4 Protective earth and EMC  \n4.3.5 Temperature sensor wires  \n4.3.6 Temperature protection  \n4.3.7 PTC speci cation  \n4.3.8 KTY speci cation  \n4.3.9 Polarization test  \n4.4 De-installation order  \n5. ADDITIONAL INSTALLATIONS  \n5.1 Analog Hall module  \n5.1.1 Mechanical interface  \n5.1.2 Electrical interface  \n5.2 Digital Hall module  \n5.2.1 Mechanical interface  \n5.2.2 Electrical interface  \n5.3 Stainless steel cover  \n6. OPERATION  \n6.1 Pre-commissioning  \n6.2 Con guring  \n6.3 Testing  \n6.4 Starting up  \n6.5 Conditions  \n6.5.1 Storage conditions  \n6.5.2 Transport conditions  \n6.5.3 Operational conditions  \n24  \n28  \n29  \n29  \n30  \n32  \n34  \n34  \n34  \n35  \n35  \n35  \nTABLE OF CONTENTS 3  \nIron core l inear motor manual -ver. 2.0  \nAPPENDIX  \nAPPENDIX A 39  \nDimensions  \nAPPENDIX B 47  \nCoupling  \nAPPENDIX C 52  \nMotor cable con guration  \nAPPENDIX D 53  \nTemperature sensor location  \nAPPENDIX E 54  \nPackage weight  \nAPPENDIX F 55  \nF/v graphs  \nGLOSSARY 65  \nTABLE OF CONTENTS 4  \nIron core l inear motor manual -ver. 2.0  \n1. BEFORE YOU START  \nThis is the manual for your Tecnotion iron core motor. Please read this manual very carefully. The information provided is important for a safe and warranted installation and operation of the motor. Be sure to have this manual at hand when installing or working with the motor.  \nAbout this manual  \nThis manual describes the use of a Tecnotion iron core linear motor system. These motors can be applied in numerous application devices. This manual is intended for technicians who construct a machine that includes an iron core linear motor. It will give insight what aspects to consider for the design and installation of a linear motor.  \nIntended use  \nAn iron core linear motor system is a permanent magnet","cbCairSEF7wCF93e","https://ap.wps.com/l/cbCairSEF7wCF93e","pdf",2791451,67,"English","# 1. Before you start\n## 1.1 Important notices\n## 1.2 Safety warnings\n## 1.3 Certification\n# 2. Motor components\n## 2.1 Basic components\n## 2.2 Additional parts\n# 3. Motor configuration\n## 3.1 Configuration options\n## 3.2 Heat transfer\n# 4. Installation\n## 4.1 Cleaning\n## 4.2 Installation\n## 4.3 Electrical connections\n## 4.4 De-installation order\n# 5. Additional installations\n## 5.1 Analog Hall module\n## 5.2 Digital Hall module\n## 5.3 Stainless steel cover\n# 6. Operation\n## 6.1 Pre-commissioning\n## 6.2 Configuring\n## 6.3 Testing\n## 6.4 Starting up\n## 6.5 Conditions\n# Appendix\n## Appendix A Dimensions\n## Appendix B Coupling\n## Appendix C Motor cable configuration\n## Appendix D Temperature sensor location\n## Appendix E Package weight\n## Appendix F F/v graphs\n# Glossary","[{\"question\":\"What is the intended use of the Tecnotion iron core linear motor system?\",\"answer\":\"It is intended for wherever linear motion along an axis is required. It is designed as a permanent magnet direct drive motor and must be used only as intended, since other uses are not warranted.\"},{\"question\":\"What safety precautions are important before installing the linear motor?\",\"answer\":\"Read the instruction manual carefully and follow the provided requirements. Magnet plates have strong attraction forces and can cause serious jamming danger, so soft magnetic objects must not be brought closer than 25 centimeters.\"},{\"question\":\"How should the magnet plates be handled and protected during installation?\",\"answer\":\"Handle components with care both packed and unpacked. Avoid mechanical shocks: never drop a magnet plate or release it uncontrolled. Do not expose magnets to temperatures higher than 70°C to prevent demagnetization.\"}]","Iron core linear motor manual -ver. 2.0 - Installation and operation guide | PDF",169]