[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-352426-105":59,"doc-detail-352426-en":135},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":128,"head_meta":130,"extra_data":132,"updated_unix":134},105,"en","ir-spectroscopy-and-linear-support-vector-machine-analysis-of-colorectal-liver-metastasis","IR Spectroscopy and Linear Support Vector Machine Analysis of Colorectal Liver Metastasis","","The Colorectal Liver Metastasis (CLM) library provides 756,096 full-range FTIR microscope imaging spectra from 14 frozen tissue sections across 7 consenting patients. A subset of 30 windows from predominant tumor and nontumor regions supports training and testing of linear support vector machine (SVM) models. With few patients, the study uses the spectrum volume to frame IR spectroscopy from a physical chemistry perspective. A Leave-One-Case-Out strategy trains the model to reduce overtraining and leakage while enabling simple feature selection, yielding a “Decision Contribution Spectrum.” Results guide designing a fast mid-IR operating-room cancer probe for rapid margin decisions using narrower spectral range and larger wavenumber step intervals than FTIR.",{"@graph":69,"@context":127},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/ir-spectroscopy-and-linear-support-vector-machine-analysis-of-colorectal-liver-metastasis/352426/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/ir-spectroscopy-and-linear-support-vector-machine-analysis-of-colorectal-liver-metastasis/352426.png","ImageObject",300,407,{"name":92,"@type":93},"Theodore","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-23","2026-09-22",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119,123],{"name":110,"@type":111,"acceptedAnswer":112},"What data does the CLM library contain and how was it collected?","Question",{"text":113,"@type":114},"The CLM library includes 756,096 full-range FTIR microscope imaging spectra derived from 14 frozen tissue sections from 7 consenting patients with colorectal-origin liver metastasis.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How were linear SVM models trained and what strategy was used to prevent data leakage?",{"text":118,"@type":114},"Linear SVM models used a Leave-One-Case-Out strategy to avoid case leakage, minimize overtraining, and support simple feature selection from defined spectral windows.",{"name":120,"@type":111,"acceptedAnswer":121},"What is the “Decision Contribution Spectrum” and how is it used?",{"text":122,"@type":114},"It is the measured spectral form that quantifies the summed support-vector response contributing to the tumor versus nontumor decision at each spectral step.",{"name":124,"@type":111,"acceptedAnswer":125},"How do the results support the development of a fast mid-IR cancer probe?",{"text":126,"@type":114},"They inform a mid-IR probe design that provides quick intraoperative tumor decisions by using a reduced spectral range and an increased interval between wavenumber steps relative to the full FTIR input data.","https://schema.org",{"og:url":83,"og:type":129,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":131,"canonical":83},"index,follow",{"doc_id":133,"site_id":62},352426,1790196933,{"code":4,"msg":5,"data":136},{"doc_id":133,"user_id":137,"nickname":92,"user_avatar":138,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":139,"file_id":140,"file_url":141,"file_type":142,"file_size":143,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":144,"language":145,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":146,"faqs":147,"seo_title":148,"seo_description":67,"update_tm":149,"read_time":41,"preview_page_count":19,"preview_urls":150},7971461740886,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","This article is licensed under CC-BY 4.0   \n[pubs.acs.org/JPCB](pubs.acs.org/JPCB)  Article   \nIR Spectroscopy and Linear Support Vector Machine Analysis of Colorectal Liver Metastasis  \nJames V. Coe, * Heather C. Allen, Samantha A. Skarda, Trina D. Orr, Antrae L. Wilson II,  \nDestiny G. Wilson, Susan Kalliantas, Steven V. Nystrom, Rebecca C. Bradley, Ran Li, Zhaomin Chen, Charles. L. Hitchcock, and Edward W. Martin Jr.  \n Cite This: J. Phys. Chem. B 2026, 130, 1798−1809  \nRead Online  \n\n|  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- |\n| ACCESS   | Metrics & More |  |  Article Recommendations |  | *sı Supporting Information |\n\nABSTRACT: The Colorectal Liver Metastasis (CLM) library contains 756,096 full range Fourier transform infrared (FTIR) microscope imaging spectra of 14 frozen tissue sections from 7 different consenting patients with liver metastasis of colorectal origin. A subset of 30 windows was defined in predominant tumor or nontumor regions for the training or testing of linear support vector machine (SVM) models. Since the number of consenting patients was small, the primary purpose of this work was to establish a physical chemistry perspective on the infrared (IR) spectroscopy of metastatic liver cancer using the large number of available spectra. The linear SVM model was trained with a LeaveOne-Case-Out strategy to avoid case leakage, minimize overtraining, and offer simple feature selection. The primary result is the derivation and measurement of a spectral form for the average contribution to the tumor/nontumor decision at each spectral step, i.e., the “Decision Contribution Spectrum”. Finally, the results are used toward the design of a fast mid-IR cancer probe for the operating room giving quick tumor decisions despite a reduced range of wavenumbers and an increased interval between wavenumber steps as compared to the FTIR input spectral data.  \n1. INTRODUCTION  \nThis preclinical study produced the Colorectal Liver Metastasis (CLM) library which contains 756,096 full range infrared (IR) spectra, each corresponding to a spatial pixel size of 6.25 μm x 6.25 μm in a tissue section (spectral range 4000−750 cm−1 with 1626 steps of 2 cm−1 and spectral resolution of 4 cm−1). The CLM library has 1.23 billion pairs of information for analysis which have been applied to a variety of issues, but most importantly to identify the signatures of basic IR absorption spectroscopy for identifying liver tumors. Machine learning techniques are gaining wide attention for vibrational spectroscopy in biomedical applications. 1−5 Mid-IR vibrational imaging spectroscopy is recognized for its ability to detect cancer5−12 without the need for labels such as fluorophores, radiolabels, and monoclonal antibodies.5, 13 Ongoing work on diagnostic methods provides a growing foundation.5, 14−19 The American Cancer Society tabulated 195,900 cases of rectal, colon, and colorectal cancer and 53,200 deaths in the year 2022 in the United States. Something like 70% of these cases metastasized to the liver. The liver is often the first place for metastasis because it regulates biochemical synthesis, degradation, and detoxification20 as the body’s chemical plant, interconnecting bile ducts, lymph nodes, and the blood circulatory system. The liver is unlike many other human  \ninternal organs in that it regenerates,21,22 so surgical resection of tumors is a particularly effective treatment relative toresections in other organs with metastatic tumors.  \nThe immediate goal of this work is the derivation and measurement of the “Decision Contribution Spectrum” which quantifies the summed response of all support vectors at each wavelength to the cancer decision. Excellent signal-to-noise ratio was obtained because the CLM library is so large. The long-range goal of this work is to see if a fast mid-IR spectral probe based on a quantum cascade laser23−28 (QCL, with reduced spectral range relative to FTIR and increased interval between steps for spee","cbCaiasAexwHcFWB","https://ap.wps.com/l/cbCaiasAexwHcFWB","pdf",12111468,12,"English","# Abstract\n# Introduction\n# Linear Support Vector Machine Decision Equations for Spectroscopy","[{\"question\":\"What data does the CLM library contain and how was it collected?\",\"answer\":\"The CLM library includes 756,096 full-range FTIR microscope imaging spectra derived from 14 frozen tissue sections from 7 consenting patients with colorectal-origin liver metastasis.\"},{\"question\":\"How were linear SVM models trained and what strategy was used to prevent data leakage?\",\"answer\":\"Linear SVM models used a Leave-One-Case-Out strategy to avoid case leakage, minimize overtraining, and support simple feature selection from defined spectral windows.\"},{\"question\":\"What is the “Decision Contribution Spectrum” and how is it used?\",\"answer\":\"It is the measured spectral form that quantifies the summed support-vector response contributing to the tumor versus nontumor decision at each spectral step.\"},{\"question\":\"How do the results support the development of a fast mid-IR cancer probe?\",\"answer\":\"They inform a mid-IR probe design that provides quick intraoperative tumor decisions by using a reduced spectral range and an increased interval between wavenumber steps relative to the full FTIR input data.\"}]","IR Spectroscopy and Linear Support Vector Machine Analysis of Colorectal Liver Metastasis | PDF",1790099528,[151,155,159,163],{"page_no":8,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/b330b5c6c23f3d939da87cab34e4f0d2.webp",983,1296,{"page_no":14,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/4881a70c092daaa64d4725bcfe76db19.webp",982,1295,{"page_no":81,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/7b77b186b9dba908444746b516ccc273.webp",981,1293,{"page_no":19,"url":164,"width":165,"height":166},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/e8fc5f1a04245fa5ab87fc8d6846a9f9.webp",980,1292]