[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663628-105":59,"doc-detail-663628-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","iqt-range-instructions-for-safe-use-installation-basic-setup-and-maintenance","IQT range - Instructions for Safe Use, Installation, Basic Setup and Maintenance","","Manual provides essential safety information for IQT3 and IQT3 Pro actuators covering safe installation, operation, basic setup, and maintenance. It details safety and health topics including ATEX/IECEx/UKEX and CSA Japan certifications, storage requirements, operating modes (manual and electrical), local display and status/alarm indications, and battery alarm behavior. It also covers drive bush preparation, actuator mounting, cable connections, commissioning basic settings and limits, and maintenance, monitoring, troubleshooting, decommissioning, approvals, vibration/noise, and safe-use conditions.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/iqt-range-instructions-for-safe-use-installation-basic-setup-and-maintenance/663628/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/iqt-range-instructions-for-safe-use-installation-basic-setup-and-maintenance/663628.png","ImageObject",300,407,{"name":92,"@type":93},"Guten Appetit_Joghurt","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Which actuators are covered by this manual?","Question",{"text":112,"@type":113},"The manual covers IQT3 and IQT3 Pro actuators, including their operation for isolating/regulating 1/4 turn valves, modulating 1/4 turn valves, and part-turn/slow speed multi-turn valves for modulating duty.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What setting options are available for configuring IQT3 actuators?",{"text":117,"@type":113},"IQT3 actuators can be configured using the Rotork app (smartphones for IQT3 Pro only), the Rotork Bluetooth Setting Tool Pro handset, or manual setup using local control knobs on the actuator (IQT3 Pro only).",{"name":119,"@type":110,"acceptedAnswer":120},"What safety and regulatory certifications are addressed?",{"text":121,"@type":113},"The manual includes health and safety information for ATEX, IECEx, UKEX, and CSA Japan certified actuators, as well as Indian Ex certified actuators, along with conditions of safe use and flamepath/thread details.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663628,1793229690,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},1374408768420,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","IQT range    \nInstructions for safe use, installation, basic setup and maintenance  \n This manual contains important safety information. Please ensure it is thoroughly read and understood before installing, operating or maintaining the equipment.  \nPUB002-065-00 Date of issue 10/26  \n1. Introduction_____________________________3  \n1.1 Identifying Actuator Parts .................. 4  \n1.2 Identifying IQT Actuator Type ............... 5  \n1.3 Setting Options .......................... 6  \n1.4 Rotor k App ............................. 6  \n1.5 Rotork Setting Tool ....................... 7  \n2. Health and Safety _______________________8  \n2.1 ATEX, IECEx, UKEX and CSA Japan Certified Actuators ...................... 10  \n2.2 Indian Ex Certified Actuators .............. 10  \n3. Storage _______________________________ 10  \n4. Operating your IQT Actuator ___________ 11  \n4.1 Operating by Hand ...................... 11  \n4.2 Operating Electrically .................... 11  \n4.3 Display – Local Indication ................. 12  \n4.4 Display – Home Screen Selection ........... 13  \n4.5 Display Status Indication – Travel ........... 14  \n4.6 Display Status Indication – Control .......... 14  \n4.7 Display Alarm Indication .................. 14  \n4.8 Battery Alarm .......................... 14  \n5. Preparing the Drive Bush_______________ 15  \n5.1 Bases F05 to F07 and FA05 to FA07 ......... 15  \n5.2 Bases F10 to F16 and FA10 to FA16 .......... 15  \n5.3 Machining the Drive Bush ................. 15  \n5.4 Fitting the Drive Bush .................... 15  \n6. Mounting the Actuator ________________ 16  \n6.1 IQT Actuators .......................... 16  \n6.2 IQTM Actuators ........................ 16  \n6.3 IQTF Actuators ......................... 16  \n6.4 Lifting the Actuator ..................... 16  \n6.5 Securing Actuator to Valve ................ 17  \n6.6 Stop Bolts ............................. 17  \n7. Cable Connections _____________________ 18  \n7.1 Terminal Block Layout .................... 18  \n7.2 Earth/Ground Connections ................ 18  \n7.3 Removing Terminal Cover ................. 18  \n7.4 Cable Entry ............................ 19  \n7.5 Connecting to Terminals .................. 19  \n7.6 Replacing Terminal Cover ................. 19  \n8. Commissioning-Basic Settings _________ 20  \n8.1 Connecting to the Actuator Using Rotork Setting Tool ...................... 21  \n8.2 Connecting to the Actuator Using Manual Setup .......................... 22  \n8.3 Security – Password ..................... 23  \n8.4 Basic Settings Menu ..................... 24  \n8.5 Basic Settings – Limits .................... 25  \n8.6 Close Settings .......................... 26  \n8.7 Open Settings .......................... 27  \n8.8 Breakout Torque ........................ 27  \n9. Maintenance, Monitoring and Troubleshooting _______________________ 29  \n10. Decommissioning and Environmental Considerations ________________________ 33  \n11. Weights and Measures_________________ 34  \n12. IQT Approvals _________________________ 35  \n13. Approved Fuses _______________________ 38  \n14. Vibration, Shock and Noise_____________ 38  \n15. Conditions of Safe Use _________________ 39  \n15.1 Thread details for ATEX, IECEx and UKEX approved actuators ...................... 39  \n15.2 Maximum constructional flamepath gaps for  \nATEX, IECEx and UKEX approved actuators ... 39  \n16. IQT Shutdown Battery Operating Conditions ____________________________ 40  \n16.1 Shutdown Battery Commissioning .......... 41  \nThis manual covers IQT3 and IQT3 Pro actuators:  \nIQT Operation of isolating/ regulating 1/4 turn valves  \nIQTM Operation of modulating  \n1/4 turn valves  \nIQTF Operation of part-turn and slow speed multi-turn valves for modulating duty  \nThis manual provides instruction on:  \n• Manual and electrical (local and remote) operation  \n• Preparation and installation of the actuator onto the valve  \n• Basic commissioning  \n• Maintenance  \nRefer to publication PUB002-067 for repair, overha","cbCaia3LlBoXiHu4","https://ap.wps.com/l/cbCaia3LlBoXiHu4","pdf",3237341,44,"English","# Introduction\n## Identifying Actuator Parts\n## Identifying IQT Actuator Type\n## Setting Options\n## Rotor k App\n## Rotork Setting Tool\n# Health and Safety\n## ATEX, IECEx, UKEX and CSA Japan Certified Actuators\n## Indian Ex Certified Actuators\n# Storage\n# Operating your IQT Actuator\n## Operating by Hand\n## Operating Electrically\n## Display – Local Indication\n## Display – Home Screen Selection\n## Display Status Indication – Travel\n## Display Status Indication – Control\n## Display Alarm Indication\n## Battery Alarm\n# Preparing the Drive Bush\n## Bases F05 to F07 and FA05 to FA07\n## Bases F10 to F16 and FA10 to FA16\n## Machining the Drive Bush\n## Fitting the Drive Bush\n# Mounting the Actuator\n## IQT Actuators\n## IQTM Actuators\n## IQTF Actuators\n## Lifting the Actuator\n## Securing Actuator to Valve\n## Stop Bolts\n# Cable Connections\n## Terminal Block Layout\n## Earth/Ground Connections\n## Removing Terminal Cover\n## Cable Entry\n## Connecting to Terminals\n## Replacing Terminal Cover\n# Commissioning - Basic Settings\n## Connecting to the Actuator Using Rotork Setting Tool\n## Connecting to the Actuator Using Manual Setup\n## Security – Password\n## Basic Settings Menu\n## Basic Settings – Limits\n## Close Settings\n## Open Settings\n## Breakout Torque\n# Maintenance, Monitoring and Troubleshooting\n# Decommissioning and Environmental Considerations\n# Weights and Measures\n# IQT Approvals\n# Approved Fuses\n# Vibration, Shock and Noise\n# Conditions of Safe Use\n## Thread details for ATEX, IECEx and UKEX approved actuators\n## Maximum constructional flamepath gaps for ATEX, IECEx and UKEX approved actuators\n# IQT Shutdown Battery Operating Conditions\n## Shutdown Battery Commissioning","[{\"question\":\"Which actuators are covered by this manual?\",\"answer\":\"The manual covers IQT3 and IQT3 Pro actuators, including their operation for isolating/regulating 1/4 turn valves, modulating 1/4 turn valves, and part-turn/slow speed multi-turn valves for modulating duty.\"},{\"question\":\"What setting options are available for configuring IQT3 actuators?\",\"answer\":\"IQT3 actuators can be configured using the Rotork app (smartphones for IQT3 Pro only), the Rotork Bluetooth Setting Tool Pro handset, or manual setup using local control knobs on the actuator (IQT3 Pro only).\"},{\"question\":\"What safety and regulatory certifications are addressed?\",\"answer\":\"The manual includes health and safety information for ATEX, IECEx, UKEX, and CSA Japan certified actuators, as well as Indian Ex certified actuators, along with conditions of safe use and flamepath/thread details.\"}]","IQT range - Instructions for Safe Use, Installation, Basic Setup and Maintenance | PDF",111]