[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663451-105":59,"doc-detail-663451-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","ip-66-enclosure-technical-data-and-operating-conditions","IP 66 Enclosure - Technical Data and Operating Conditions","","Technical specifications for a grey PC (polycarbonate) enclosure with transparent lid, rated for protection class IP 66 and mechanical impact IK08 (5 Joule). Includes built-in mounting dimensions (DIN rail or mounting plate), maximum installation depth, insulation voltage Ui, weight, lid fastening and sealed design without knockouts, plus power dissipation capability at Δϑ=40 K. Operating and ambient conditions define indoor/outdoor use (protected from weather), temperature range from -25°C to +70°C, fire and burning behaviour tests (glow-wire per IEC 60695-2-11 and UL 94 V-2), and halogen-free, toxic behaviour requirements. Notes address UV resistance, outdoor climate effects, condensation prevention and material properties.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/ip-66-enclosure-technical-data-and-operating-conditions/663451/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/ip-66-enclosure-technical-data-and-operating-conditions/663451.png","ImageObject",300,407,{"name":92,"@type":93},"iuabcfuw","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the key protection ratings and materials of the enclosure?","Question",{"text":112,"@type":113},"The enclosure is rated IP 66 for degree of protection and IK08 (5 Joule) for impact strength. It uses PC (polycarbonate) material and includes a transparent lid.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What operating and ambient temperature limits are specified?",{"text":117,"@type":113},"Ambient temperature limits are maximum +70 °C and minimum -25 °C. The document also states the installation area supports indoor and outdoor use protected against weather influences.",{"name":119,"@type":110,"acceptedAnswer":120},"Which fire protection and burning behaviour tests are required?",{"text":121,"@type":113},"Fire protection includes glow wire test requirements per IEC 60695-2-11, with 650 °C for boxes and cable glands and 850 °C for parts of insulating material necessary to retain current-carrying parts. Burning behaviour includes glow wire test at 960 °C and UL Subject 94 V-2, described as flame-retardant and self-extinguishing.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663451,1793227810,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":66,"faqs":140,"seo_title":141,"seo_description":67,"update_tm":129,"read_time":39},3985747874027,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Cable glands, degree of protection IP 66 (750 °C)  \nK 0200  \n Built-in dimensions W 275 x H 275 x D 150 mm  \nenclosure size 2 , type Mi  \n for installation equipment on DIN rails or mounting plates (order separately)  \n max. installation depth with built-in mounting plate 146 mm , with built-in DIN rail 135 mm  \n with transparent lid  \n lid fasteners for tool operation  \n sealable  \n box walls without knockouts  \n optional hinges for device installation in the lid  \n external brackets for wall fixing as accessories  \n colour: grey , RAL 7035  \n material: PC (polycarbonate)  \nrated insulation voltage Ui = 690 V a.c. / 1000 V d.c.  \nimpact strength IK 08 (5 Joule)  \nstatic load mounting plate or DIN rail = 6.5 kg  \nlid = 1.6 kg  \npower dissipation capability at Δϑ = 40 K Pde = 53 watts  \nwall thickness enclosure = 3 mm  \nlid = 3 mm  \nmaterial PC (Polycarbonate)  \ndegree of protection IP 66  \nmounting width 275 mm  \nmounting height 275 mm  \nmax. installation depth with built-in mounting plate 146 mm  \nmax. installation depth with built-in DIN rail 135 mm  \nwidth 300 mm  \nheight 300 mm  \ndepth 170 mm  \n\n| weight | 2 ,08 kg |\n| --- | --- |\n| in accordance with\u003Cbr>Drawings | IEC 62208:2011 |\n\nPage 1 of 3  \nGustav Hensel GmbH & Co. KG * Gustav-Hensel-Str. 6 * 57368 Lennestadt * Germany * Telefon: +49 (0)2723/609-0 * Fax: +49 (0)2723/60052 * Date: July 4. 2024  \nDimension drawing  \nDetail mass  \nOperating and ambient conditions  \nApplication area Suitable for indoor installation and outdoor installation ,  \nprotected against weather influences  \nHowever , pay attention to the climatic effects on the installed equipment , for example , high or low ambient temperatures or formation of condensed water see technical information  \n\n| Ambient temperature | Maximum value + 70 °C\u003Cbr>Minimum value-25 °C |\n| --- | --- |\n| Fire protection in the event of internal faults | Demands placed on electrical devices from standards and laws\u003Cbr>Minimum requirements\u003Cbr>-Glow wire test in accordance with IEC 60695-2-11 :\u003Cbr>-650°C for boxes and cable glands\u003Cbr>-850°C for parts of insulating material necessary to retain current carrying parts in position |\n| Burning behaviour | Glow wire test IEC 60695-2-11 : 960 °C\u003Cbr>UL Subject 94: V-2\u003Cbr>flame-retardant\u003Cbr>self-extinguishing |\n| Degree of protection against mechanical load | IK08 (5 Joule) |\n\nPage 2 of 3  \nGustav Hensel GmbH & Co. KG * Gustav-Hensel-Str. 6 * 57368 Lennestadt * Germany * Telefon: +49 (0)2723/609-0 * Fax: +49 (0)2723/60052 * Date: July 4. 2024  \nToxic behaviour halogen-free  \nsilicone-free  \n\"halogen-free\" in accordance with the examination of the cables and insulated wires-corrosiveness of fumes-as per IEC 60754-2  \nNote: Supplementing references regarding outdoor installation: -  \nThe materials used for K 0xxx empy enclosures are basically UV resistant , so that the mechanical resistance of the boxes is maintained during UV effect. Depending on the intensity of the UV effect e.g. transparent lids can change colour. -The top side of the boxes should be protected by a cover against weather influences such as rains , ice and snow. - Further on , also chemical influences have to be considered with the selection of the installation place-apart from the IP rating and climatic effects. - In order to keep the maximum permissible ambient temperature of the installed equipment as well as for the prevention of condensation additional measures as ventilation and/or heating may be necessary.  \nFor material properties see technical data.  \nPage 3 of 3  \nGustav Hensel GmbH & Co. KG * Gustav-Hensel-Str. 6 * 57368 Lennestadt * Germany * Telefon: +49 (0)2723/609-0 * Fax: +49 (0)2723/60052 * Date: July 4. 2024","cbCaiplJCorKb62I","https://ap.wps.com/l/cbCaiplJCorKb62I","pdf",845435,"English","[{\"question\":\"What are the key protection ratings and materials of the enclosure?\",\"answer\":\"The enclosure is rated IP 66 for degree of protection and IK08 (5 Joule) for impact strength. It uses PC (polycarbonate) material and includes a transparent lid.\"},{\"question\":\"What operating and ambient temperature limits are specified?\",\"answer\":\"Ambient temperature limits are maximum +70 °C and minimum -25 °C. The document also states the installation area supports indoor and outdoor use protected against weather influences.\"},{\"question\":\"Which fire protection and burning behaviour tests are required?\",\"answer\":\"Fire protection includes glow wire test requirements per IEC 60695-2-11, with 650 °C for boxes and cable glands and 850 °C for parts of insulating material necessary to retain current-carrying parts. Burning behaviour includes glow wire test at 960 °C and UL Subject 94 V-2, described as flame-retardant and self-extinguishing.\"}]","IP 66 Enclosure - Technical Data and Operating Conditions | PDF"]