[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-561651-105":59,"doc-detail-561651-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","inverter_emc-report-summary-of-standards-and-results","inverter_emc-report - Summary of Standards and Results","","Document provides a structured EMC test summary for a solar inverter, detailing emissions and immunity performance against specific IEC EN standards. It lists conducted and radiated disturbance outcomes, including harmonic current and voltage fluctuation/flicker results, and presents immunity test item criteria with pass/fail or N/A status. The report includes general performance criterion definitions, measurement uncertainty statements, and uncertainty calculation references tied to CISPR 16-4 and DIN EN ISO/IEC 17025, plus device description and electrical specifications.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/inverter_emc-report-summary-of-standards-and-results/561651/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/inverter_emc-report-summary-of-standards-and-results/561651.png","ImageObject",300,407,{"name":92,"@type":93},"Aldword","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-12","2026-10-12",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What emissions tests are summarized, and what are the reported outcomes?","Question",{"text":113,"@type":114},"The summary covers conducted disturbance at mains terminals, conducted disturbance at telecommunication ports, radiated disturbance, harmonic current emissions, and voltage fluctuations & flicker, with results including PASS for radiated disturbance, harmonic currents, and flicker-related items while some conducted results are N/A.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"Which immunity test items are included in the report summary?",{"text":118,"@type":114},"Immunity items include electrostatic discharge (ESD), radio-frequency continuous radiated disturbance, electrical fast transient (EFT), surge on input AC power ports, surge on telecommunication ports, radio-frequency continuous conducted disturbance, power frequency magnetic field, and voltage dips/interruptions, with results marked PASS or N/A depending on the criterion.",{"name":120,"@type":111,"acceptedAnswer":121},"How is measurement uncertainty stated and referenced?",{"text":122,"@type":114},"The report states that measurement uncertainty was calculated for measurements listed in the EMC test report according to CISPR 16-4 and documented in the AOC quality system in line with DIN EN ISO/IEC 17025, and it provides uncertainty values by frequency range with an expanded uncertainty at approximately 95% confidence level using k=2.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},561651,1791893231,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":36,"preview_page_count":19,"preview_urls":146},2336478940917,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","SUMMARY OF STANDARDS AND RESULTS  \nDescription of Standards and Results  \n\n| EMISSION (EN IEC 61000-6-3:2021) |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- |\n| Description of Test Item | Standard |  |  | Limits | Results |\n| Conducted disturbance at mains terminals | EN 55032: 2015+A11:2020 |  |  | Class B | N/A |\n| Conducted disturbance at telecommunication port | EN 55032: 2015+A11:2020 |  |  | Class B | N/A |\n| Radiated disturbance | EN 55032: 2015+A11:2020 |  |  | Class B | PASS |\n| Harmonic current emissions | EN IEC 61000-3-2:2019+A1: 2021 |  |  | Class A | PASS |\n| Voltage fluctuations & flicker | EN 61000-3-3:2013+A1:2019+A2:2021 |  |  | -------- | PASS |\n| IMMUNITY (EN IEC 61000-6-1:2019 ) |  |  |  |  |  |\n| Description of Test Item |  | Basic Standard | Performance Criteria |  | Results |\n| Electrostatic discharge (ESD) |  | EN 61000-4-2:2009 | B |  | PASS |\n| Radio-frequency,\u003Cbr>Continuous radiated disturbance |  | EN 61000-4-3:2020 | A |  | PASS |\n| Electrical fast transient (EFT) |  | EN 61000-4-4:2012 | B |  | N/A |\n| Surge (Input a. c. power ports) |  | EN 61000-4-5: 2014+A1:2017 | B |  | N/A |\n\n\n| Surge (Telecommunication ports) |  | B | N/A |\n| --- | --- | --- | --- |\n| Radio-frequency,\u003Cbr>Continuous conducted disturbance | EN 61000-4-6: 2014+AC:2015 | A | N/A |\n| Power frequency magnetic field | EN 61000-4-8: 2010 | A | PASS |\n| Voltage dips, >95% reduction | EN 61000-4-11:2020+AC:2020 | C | N/A |\n| Voltage dips, 30% reduction |  | C | N/A |\n| Voltage interruptions |  | C | N/A |\n| N/A is an abbreviation for Not Applicable. |  |  |  |\n\nDescription of Performance Criteria  \nGeneral Performance Criteria  \nExamples of functions defined by the manufacturer to be evaluated during testing include, but are not limited to, the following: ─ essential operational modes and states;  \n─ tests ofall peripheral access (hard disks, floppy disks, printers, keyboard, mouse, etc.);─ quality of software execution;  \n─ quality of data display and transmission; ─ quality of speech transmission.  \nPerformance criterion A  \nThe equipment shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed below a performance level specified by the manufacture when the equipment is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be deriver from the product description and documentation, and by what the user may reasonably expect from the equipment if used as intended.  \nPerformance criterion B  \nAfter the test, the equipment shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed, after the application of the phenomena below a performance level specified by the manufacture, when the equipment is used as intended. The performance level may be replaced by a permissible loss of performance.  \nDuring the test, degradation of performance is allowed. However, no change of operation state or stored data is allowed to persist after the test.  \nIf the minimum performance level (or the permissible performance loss) is not specified by the manufacturer, then either of these may be deriver from the product description and documentation, and by what the user may reasonably expect from the equipment if used as intended.  \nPerformance criterion C  \nLoss of function is allowed, provided the function is self-recoverable, or can be restored by the operation of the controls by the user in accordance with the manufacture’s instructions.  \nFunctions, and/or information stored in non-volatile memory, or protected by a battery backup, shall not be loss.  \n2. GENERAL INFORMATION  \n2.1.Description of Device (EUT)  \nEUT  \nModel Number  \nPower Supply  \n:  \n:  \n:  \nSolar Inverter  \n5.5KW, 3.5KW, 2 .4KW, 1.5KW  \nInput：AC 90V-280V, 50Hz/60Hz, 38.5A","cbCaiieLBtK0CXEo","https://ap.wps.com/l/cbCaiieLBtK0CXEo","pdf",1060235,16,"English","# Summary of Standards and Results\n## Emissions (EN IEC 61000-6-3:2021)\n## Immunity (EN IEC 61000-6-1:2019)\n## Description of Performance Criteria\n## General Information\n## Description of Device (EUT)\n## Statement of the Measurement Uncertainty\n## Measuring Devices and Test Equipment","[{\"question\":\"What emissions tests are summarized, and what are the reported outcomes?\",\"answer\":\"The summary covers conducted disturbance at mains terminals, conducted disturbance at telecommunication ports, radiated disturbance, harmonic current emissions, and voltage fluctuations \\u0026 flicker, with results including PASS for radiated disturbance, harmonic currents, and flicker-related items while some conducted results are N/A.\"},{\"question\":\"Which immunity test items are included in the report summary?\",\"answer\":\"Immunity items include electrostatic discharge (ESD), radio-frequency continuous radiated disturbance, electrical fast transient (EFT), surge on input AC power ports, surge on telecommunication ports, radio-frequency continuous conducted disturbance, power frequency magnetic field, and voltage dips/interruptions, with results marked PASS or N/A depending on the criterion.\"},{\"question\":\"How is measurement uncertainty stated and referenced?\",\"answer\":\"The report states that measurement uncertainty was calculated for measurements listed in the EMC test report according to CISPR 16-4 and documented in the AOC quality system in line with DIN EN ISO/IEC 17025, and it provides uncertainty values by frequency range with an expanded uncertainty at approximately 95% confidence level using k=2.\"}]","inverter_emc-report - Summary of Standards and Results | PDF",1791806481,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/4b19958017f8a31766e0ed0c4b65c5d1.webp",983,1390,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/62a611fed97f72d2585398e529cc04fc.webp",982,1388,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/e810526cd8920def5cbd3e615ded7f28.webp",981,1387,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/805d96524e2751b30647e6c94ddf0692.webp",980,1385]