[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-297648-105":59,"doc-detail-297648-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","intertherm-751csa-application-guidelines-document","Intertherm 751CSA Application Guidelines - Document","","Intertherm 751CSA Application Guidelines provide detailed, professional direction for applying Intertherm 751CSA as an anti-corrosive barrier on correctly prepared steel surfaces, including areas exposed to wet/dry thermal cycling under insulation. The guidance covers where to apply, appropriate temperature ranges, moisture-sensitive handling, storage requirements, and the responsibilities for meeting standards during surface preparation and coating application. It emphasizes correct coating system selection, advisory technical support, and procedures for application and inspection within the outlined sections.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/intertherm-751csa-application-guidelines-document/297648/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/intertherm-751csa-application-guidelines-document/297648.png","ImageObject",300,407,{"name":92,"@type":93},"Oliver","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-23","2026-09-18",true,{"@type":102,"interactionType":103,"userInteractionCount":44},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is Intertherm 751CSA designed to do?","Question",{"text":112,"@type":113},"Intertherm 751CSA is designed to provide a corrosion-resistant barrier for steelwork beneath thermal insulation, particularly in conditions involving wet/dry thermal cycling. It offers corrosion protection in atmospheric service and under insulation without additional heat curing before service.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Where and how can Intertherm 751CSA be applied?",{"text":117,"@type":113},"It is typically applied direct to metal as a one- or two-coat system, effective for mitigating corrosion under insulation (CUI). It can be applied directly to hot surfaces up to 150°C and is possible as a single coat up to 200 µm.",{"name":119,"@type":110,"acceptedAnswer":120},"What environmental and handling requirements are emphasized?",{"text":121,"@type":113},"The guideline states that Intertherm 751CSA is moisture sensitive during mixing and application, so environmental monitoring is important. It also specifies storage in covered, dry conditions and keeping temperature within 0°C–40°C, with adjustments such as warming or thinning at lower temperatures.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},297648,1790193483,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":44,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},8796095461610,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Intertherm 751CSA  \nApplication Guidelines  \nPrepared by: Global Technical Support  \n[www.international-pc.com](www.international-pc.com)  \nThe information in this guideline is not intended to be exhaustive; any person using the product for any purpose other than that specifically recommended in this guideline without first obtaining written confirmation from us as to the suitability of the product for the intended purpose does so at their own risk. All advice given or statements made about the product (whether in this guideline or otherwise) is correct to the best of our knowledge but we have no control over the quality or the condition of the substrate or the many factors affecting the use and application of the product. THEREFORE, UNLESS WE SPECIFICALLY AGREE IN WRITING TO DO SO, WE DO NOT ACCEPT ANY LIABILITY AT ALL FOR THE PERFORMANCE OF THE PRODUCT OR FOR (SUBJECT TO THE MAXIMUM EXTENT PERMITTED BY LAW) ANY LOSS OR DAMAGE ARISING OUT OF THE USE OF THE PRODUCT. WE HEREBY DISCLAIM ANY WARRANTIES OR REPRESENTATIONS, EXPRESS OR IMPLIED, BY OPERATION OF LAW OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. All products supplied and technical advice given are subject to our Conditions of Sale. You should request a copy of this document and review it carefully. The information contained in this guideline is liable to modification from time to time in the light of experience and our policy of continuous development. It is the user’s responsibility to check with their local International Paint representative that this guideline is current prior to using the product.  \nThe International Paint Application Guidelines have been produced and revised in line with the Worldwide Protective Coatings Product Range. The purpose of the guidelines is to ensure that the product , as applied, provides the required level of durability.  \nSuccessful in-service performance of a coating system depends upon both the correct choice of product(s) and the adoption of the correct guidelines for surface preparation and paint application.  \nThe responsibilities for achieving the specific standards outlined, and for carrying out surface preparation and paint application, rest with the Contracting Company. Under no circumstances do these responsibilities rest with International Paint. We will generally provide for the presence of a Technical Service Representative at key stages during the performance of the contract. The role of the International Paint Technical Service Representative is advisory only unless otherwise specified in the terms and conditions of the contract. The information contained herein presents guidelines for the application of Intertherm 751CSA to correctly prepared surfaces.  \nTable of Contents  \n1. Introduction  \n2. Where to Apply Intertherm 751CSA  \n3. Storage of Material  \n4. Environmental Conditions for Application  \n5. Surface Preparation  \n6. Mixing  \n7. Pot Life  \n8. Airless Spray Application  \n9. Air Spray Application  \n10. Brush and Roller Application  \n11. Standard of Cosmetic Finish  \n12. Application to Hot Substrates  \n13. Application as a Sealer Coat  \n14. Application as a Topcoat  \n15. Possible Film Defects  \n16. Adhesion Measurement  \n17. Measurement of Dry Film Thickness  \n18. Inspection and Repair  \n19. Health and Safety  \n\n| ID\u003Cbr>751CSA_uk | Rev.\u003Cbr>09 | Date\u003Cbr>31/01/2023 | Intertherm 751CSA | Page 2 of 11 |\n| --- | --- | --- | --- | --- |\n\n1. INTRODUCTION  \nIntertherm 751CSA is a novel high performance anti-corrosive that has been specifically designed to provide a corrosion resistant barrier when used to protect steelwork beneath thermal insulation in areas subjected to wet and dry cycling. It is capable of providing corrosion protection to steel in both atmospheric service and under thermal insulation operating in thermal cyclical conditions between to -196°C (-320°F) up to 650ºC (1202ºF) without the need for additional heat curing, prior to be","cbCaiegM2sVI1zkY","https://ap.wps.com/l/cbCaiegM2sVI1zkY","pdf",512747,11,"English","# Table of Contents\n## Introduction\n## Where to Apply Intertherm 751CSA\n## Storage of Material\n## Environmental Conditions for Application\n## Surface Preparation\n## Mixing\n## Pot Life\n## Airless Spray Application\n## Air Spray Application\n## Brush and Roller Application\n## Standard of Cosmetic Finish\n## Application to Hot Substrates\n## Application as a Sealer Coat\n## Application as a Topcoat\n## Possible Film Defects\n## Adhesion Measurement\n## Measurement of Dry Film Thickness\n## Inspection and Repair\n## Health and Safety","[{\"question\":\"What is Intertherm 751CSA designed to do?\",\"answer\":\"Intertherm 751CSA is designed to provide a corrosion-resistant barrier for steelwork beneath thermal insulation, particularly in conditions involving wet/dry thermal cycling. It offers corrosion protection in atmospheric service and under insulation without additional heat curing before service.\"},{\"question\":\"Where and how can Intertherm 751CSA be applied?\",\"answer\":\"It is typically applied direct to metal as a one- or two-coat system, effective for mitigating corrosion under insulation (CUI). It can be applied directly to hot surfaces up to 150°C and is possible as a single coat up to 200 µm.\"},{\"question\":\"What environmental and handling requirements are emphasized?\",\"answer\":\"The guideline states that Intertherm 751CSA is moisture sensitive during mixing and application, so environmental monitoring is important. It also specifies storage in covered, dry conditions and keeping temperature within 0°C–40°C, with adjustments such as warming or thinning at lower temperatures.\"}]","Intertherm 751CSA Application Guidelines - Document | PDF",1789746538,28]