[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-652310-105":59,"doc-detail-652310-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","intellipak-i-intellipak-ii-commercial-rooftop-air-conditionerhandler-troubleshooting-guide-july-2014","IntelliPak I & IntelliPak II - Commercial Rooftop Air Conditioner/Handler Troubleshooting Guide - July 2014","","Programming & troubleshooting guide for IntelliPak I and IntelliPak II controls used with commercial single-zone rooftop air conditioners or rooftop air handlers (VVDA/VVZT or CVDA/CVZT). Covers installation, starting up, servicing, and the associated safety advisories, including qualified personnel requirements, proper field wiring and grounding, and required personal protective equipment (PPE) with references to MSDS/SDS and OSHA/NEC guidance. Emphasizes responsible refrigerant practices, environmental concerns, certification, and compliance with applicable laws. Includes revision history notes and a table of contents for navigation.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/intellipak-i-intellipak-ii-commercial-rooftop-air-conditionerhandler-troubleshooting-guide-july-2014/652310/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/intellipak-i-intellipak-ii-commercial-rooftop-air-conditionerhandler-troubleshooting-guide-july-2014/652310.png","ImageObject",300,407,{"name":92,"@type":93},"RizkyPratama_92","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who is allowed to install and service the equipment?","Question",{"text":112,"@type":113},"Only qualified personnel should install and service the equipment. Installation, starting up, and servicing can be hazardous and requires specific knowledge and training.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the key requirements for field wiring and grounding?",{"text":117,"@type":113},"All field wiring must be performed by qualified personnel. Improper installation and grounding create FIRE and ELECTROCUTION hazards, and wiring must follow NEC and local/state electrical codes.",{"name":119,"@type":110,"acceptedAnswer":120},"What PPE must technicians use when installing or servicing?",{"text":121,"@type":113},"Technicians must put on all PPE required for the work being undertaken, and always refer to the appropriate MSDS/SDS and OSHA guidelines. If there is risk of energized electrical contact, arc, or flash, PPE must be applied according to OSHA, NFPA 70E, or local requirements before servicing.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},652310,1793148957,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},962094243231,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Programming & Troubleshooting Guide  \nIntelliPak™ I and IntelliPak™ II  \nCommercial Single Zone Rooftop Air Conditioner or Commercial Rooftop Air Handlers, with Variable Air Volume (VVDA/VVZT) Controls or Constant Air  \nVolume (CVDA/CVZT) Controls  \nIntelliPak I models S*HF*20-75 S*HL*20-75  \nS*HG*90-130 S*HK*90-130 W*HB, W*HE  \nIntelliPak II models S*HJ090-162 W*HCA-C  \n\n| SAFETYWARNING |\n| --- |\n| Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and airconditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. |\n\nJuly 2014  \nRT-SVP07D-EN  \nIntroduction  \nReadthis manualthoroughly before operating or servicing this unit.  \nWarnings, Cautions, and Notices  \nSafety advisories appear throughout this manual as required.Your personal safety and the proper operation of this machine depend upon the strict observance of these precautions.  \nThe three types of advisories are defined as follows:  \n WARNING  Indicates a potentially hazardous  \n  situation which, if not avoided, could   result in death or serious injury.  \n CAUTIONs Indicates a potentially hazardous  \n  situation which, if not avoided, could result in minor or moderate injury. It  \ncould also be used to alert against   unsafe practices.  \n NOTICE  Indicates a situationthat could result in  \n~~ ~~ equipment or property-damage only accidents.  \nImportant Environmental Concerns  \nScientific research has shown that certain man-made chemicals can affect the earth’s naturally occurring stratospheric ozone layer when released to the atmosphere. In particular, several of the identified chemicals that may affect the ozone layer are refrigerants that contain Chlorine, Fluorine and Carbon (CFCs) and those containing Hydrogen, Chlorine, Fluorine and Carbon (HCFCs) . Not all refrigerants containing these compounds have the same potential impact to the environment.Trane advocates the responsible handling of all refrigerants-including industry replacements for CFCs such as HCFCs and HFCs.  \nImportant Responsible Refrigerant Practices  \nTrane believes that responsible refrigerant practices are important to the environment, our customers, and the air conditioning industry. All technicians who handle refrigerants must be certified. The Federal Clean Air Act (Section 608) sets forth the requirements for handling, reclaiming, recovering and recycling of certain refrigerants and the equipment that is used in these service procedures. In addition, some states or municipalities may have additional requirements that must also be adhered to for responsible management of refrigerants. Know the applicable laws and follow them.  \n\n| WARNING |\n| --- |\n| Proper FieldWiring and Grounding Required!\u003Cbr>Failure to follow code could result in death or serious injury. All field wiring MUST be performed by qualified personnel. Improperly installed and grounded field wiring poses FIRE and ELECTROCUTION hazards. To avoid these hazards, you MUST follow requirements for field wiring installation and grounding as described in NEC and your local/state electrical codes. |\n\n\n| WARNING |\n| --- |\n| Personal Protective Equipment (PPE) Required!\u003Cbr>Installing/servicing this unit could result in exposure to electrical, mechanical and chemical hazards.\u003Cbr>• Before installing/servicing this unit, technicians MUST put on all PPE required for the work being undertaken (Examples; cut resistant gloves/sleeves, butyl gloves, safety glasses, hard hat/bump cap, fall protection, electrical PPE and arc flash clothing) . ALWAYS refer to appropriate Material Safety Data Sheets (MSDS)/Safety Data Sheets (SDS) and OSHA guidelines for proper PPE.\u003Cbr>• When workin","cbCaigwWTARuy9Mp","https://ap.wps.com/l/cbCaigwWTARuy9Mp","pdf",3436019,157,"English","# Introduction\n## Warnings, Cautions, and Notices\n## Important Environmental Concerns\n## Important Responsible Refrigerant Practices\n## Proper Field Wiring and Grounding Required\n## Personal Protective Equipment (PPE) Required\n## Copyright\n## Trademarks\n## Revision History\n## Commonly Used Acronyms\n## Glossary of","[{\"question\":\"Who is allowed to install and service the equipment?\",\"answer\":\"Only qualified personnel should install and service the equipment. Installation, starting up, and servicing can be hazardous and requires specific knowledge and training.\"},{\"question\":\"What are the key requirements for field wiring and grounding?\",\"answer\":\"All field wiring must be performed by qualified personnel. Improper installation and grounding create FIRE and ELECTROCUTION hazards, and wiring must follow NEC and local/state electrical codes.\"},{\"question\":\"What PPE must technicians use when installing or servicing?\",\"answer\":\"Technicians must put on all PPE required for the work being undertaken, and always refer to the appropriate MSDS/SDS and OSHA guidelines. If there is risk of energized electrical contact, arc, or flash, PPE must be applied according to OSHA, NFPA 70E, or local requirements before servicing.\"}]","IntelliPak I & IntelliPak II - Commercial Rooftop Air Conditioner/Handler Troubleshooting Guide - July 2014 | PDF",1792879526,396]