[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-674549-105":59,"doc-detail-674549-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","intek-xsg-5-user-manual-xsg-5-model-series","Intek XSG-5 User Manual - XSG-5 Model Series","","Intek XSG-5 connectionless countertop steamer unit specification and user manual detailing a 5-pan pressureless, drain-free steaming system. Describes steam generation at 212°F without water or drain connections, inverted convection fan technology, reinforced stainless steel construction, and safety controls including low-water warning with automatic shutdown. Covers gas and electrical requirements, optional accessories and auto water fill connections with venting guidance, stand and installation considerations, and a safety section with gas-leak instructions and service contact information.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/intek-xsg-5-user-manual-xsg-5-model-series/674549/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/intek-xsg-5-user-manual-xsg-5-model-series/674549.png","ImageObject",300,407,{"name":92,"@type":93},"putri.kecil17","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04",true,{"@type":101,"interactionType":102,"userInteractionCount":4},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What does connectionless operation mean for the Intek XSG-5?","Question",{"text":111,"@type":112},"The unit is designed to produce steam at 212°F without requiring water or drain connections. The manual describes drain-free venting and optional auto water fill connections for specific configurations.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What safety features are included for operation?",{"text":116,"@type":112},"The unit includes a low-water warning system with automatic shutdown control. It also provides safety warnings for installation, operation, and maintenance, and includes gas smell instructions for users.",{"name":118,"@type":109,"acceptedAnswer":119},"What are the gas and electrical requirements for the XSG-5?",{"text":120,"@type":112},"The manual specifies a 60,000 BTU/hr gas burner and provides supply pressure ranges for natural gas and propane. Electrical requirements are listed as 115 VAC, 1 phase, 5 amp.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},674549,1793764352,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":4,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":138,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":128,"read_time":143},962094509873,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","Intek Steamer model XSG-5  \nModel Numbers  \nXSG-5  \nDescription  \nThe Intek XSG connectionless countertop steamer unit has a pan capacity of 5 pans (2.5” deep 12” x 20”). Unit must be capable of producing steam at 212°F with no water or drain connection required. Unit is to have inverted convection fan technology and includes a 1 year parts and labor warranty. NSF listed as both steamer and holding cabinet. UL listed.  \nStandard Features  \n• 14 gauge reinforced stainless steel cavity-fully insulated  \n• Two panel door with rugged 14 gauge stainless steel outer door  \n• Heavy refrigeration style door handle with magnetic latch  \n• Removable stainless steel wire racks positioned to support 1”, 2.5“,4”, or 6” deep pans  \n• Inverted flow forced convection technology  \n• Magnetic door switch turns off convection fan when door is open  \n• Front mounted water reservoir drain valve  \n• 60,000 BTU/hr high-efficiency powered infrared gas burner with boilerless heating system  \n• 60-minute electro-mechanical timer, 2-position ON/OFF selector switch, indicator lights for COOK, STANDBY, HEAT and LOW WATER  \n• Low water warning system with automatic shutdown control  \n• 4” adjustable stainless steel legs with flanged feet  \n• UL–Gas, NSF Listed  \nGas  \n• 1/2” NPT  \n• 60,000 BTU/hr  \n• Supply Pressure:  \nNatural-5.00”WC minimum, 14.00” WC maximum Propane-10.00” WC minimum, 14.00” WC maximum  \n• Manufacturer must be notified if installed above  \n2,000 ft. altitude  \nElectrical  \n• 115 VAC, 1 Phase, 5 amp  \nModel XSG-5  \nOptions/Accessories  \n Stand w/Bullet Feet for Single or Double Stack  \n Casters for Stand  \n Flanged Feet for Stand  \n Door Hinged Left  \n Correction Package  \n Auto Water Fill  \n Drain Line  \n Double-Stacked Chimney Kit  \n Gas Quick-Disconnect Kit for Stand with Casters  \nOrigin of Manufacture  \nSteamer shall be designed and manufactured in the United States.  \n5 Pan Capacity Stainless Steel Pressureless, Connectionless Steamer  \nTable Top Self-Contained Gas Heated  \nShort Form  \nGroen Intek XSG 5-pan connectionless countertop steamer unit has 60,000 BTU/ hr high-efficiency powered infrared gas boilerless heating system. Heavy-duty 14 gauge stainless steel cooking compartment and door. Easyopen heavy duty magnetic door latch. Convection fan with inverted flow technology. Standard control features include: 60-minute electromechanical Timer, ON/OFFselector switch and indicating lights. 4” stainless steel adjustable legs with flanged feet. Unit includes a 1 year parts and labor warranty. Unit to be NSF and UL listed and manufactured in the U.S.A.  \nApplications  \nPasta Rice  \nVegetables (Fresh & Frozen) Seafood (Fresh & Frozen) Poultry  \nPotatoes Eggs Meats  \nReheat Cook-Chill & Prepared Foods  \nGroen Intek, Page 3 XSG REV E  \nUpdated 08/11  \nModel XSG-5  \n1 2  \nOPTIONAL AUTO WATER FILL CONNECTIONS:  \n1. 3/4” Water Supply Hose Connection  \n2. 3/4” NH Drain Connection  \nNOTE: Drain-free venting, do not connect directly to drain. Allow 2” air gap.  \nModel No. No. of  \nPans  \nVoltage KW/hr NEMA Width  \nIN  \nXSG-1 5 120/60/1 .6 5-15P 23-1/4”  \nDepth IN  \n29”  \nHeight* IN  \n30-1/4\"  \nWeight LBS  \n270  \n170944 STAND W/BULLET FEET, FOR SINGLE OR DOUBLE 27” 32.5” 47” 62 *Optional stands are 27” w x 32.5” d x 47” h, 62 lbs. Overall height of unit installed on a single stand is 60.25”.  \nOverall height of units installed on a double stand is 71.5”.  \n1055 Mendell Davis Drive, Jackson, MS 39272, 888-994-7636, [unifiedbrands.net](unifiedbrands.net)  \n© 2011 Unified Brands. All Rights Reserved. Unified Brands is a wholly-owned subsidiary of Dover Corporation.  \nModel XSG-5  \nStands shown with optional casters. Stands standard with bullet feet.  \n1055 Mendell Davis Drive, Jackson, MS 39272, 888-994-7636, [unifiedbrands.net](unifiedbrands.net)  \n© 2011 Unified Brands. All Rights Reserved. Unified Brands is a wholly-owned subsidiary of Dover Corporation.  \nUser's  Manual    \nXSG-5 Model Series  \nFOR YOUR SAFETY:  \nDo not store or use gasoline ","cbCaialiTS18O2LG","https://ap.wps.com/l/cbCaialiTS18O2LG","pdf",4203382,31,"English","# INSTALLATION\n## General Safety\n## Gas Leak Instructions\n## Operational Safety\n## Location & Placement\n## On a Stand\n## On a Stand with Casters\n## Double-Stack Assembly\n## Exhaust Hood Requirements\n## Gas Supply\n## Gas Supply Requirements\n## Installation of Gas Supply Lines\n## Testing Gas Supply Lines\n## Pressure Testing Gas Supply Lines\n## Electrical Connections","[{\"question\":\"What does connectionless operation mean for the Intek XSG-5?\",\"answer\":\"The unit is designed to produce steam at 212°F without requiring water or drain connections. The manual describes drain-free venting and optional auto water fill connections for specific configurations.\"},{\"question\":\"What safety features are included for operation?\",\"answer\":\"The unit includes a low-water warning system with automatic shutdown control. It also provides safety warnings for installation, operation, and maintenance, and includes gas smell instructions for users.\"},{\"question\":\"What are the gas and electrical requirements for the XSG-5?\",\"answer\":\"The manual specifies a 60,000 BTU/hr gas burner and provides supply pressure ranges for natural gas and propane. Electrical requirements are listed as 115 VAC, 1 phase, 5 amp.\"}]","Intek XSG-5 User Manual - XSG-5 Model Series | PDF",78]