[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-663031-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-663031-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","integral-flowmeter-technical-drawings-terminal-configuration","Integral Flowmeter - Technical Drawings - Terminal Configuration","","Technical drawings and specification tables for an Integral Flowmeter and Remote Flowtube system, including AXF model variants (AXF002, AXF005, AXF010) with ceramics lining and union-joint/ground terminal details. Provides dimension references in mm/in, weld joint and face-to-face length data, model code breakdowns, and communication-type terminal wiring layouts. Covers BRAIN/HART and Foundation Fieldbus/PROFIBUS PA terminal configurations, including functional and protective grounding guidance and notes for explosion-proof indicator options and general tolerances.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/integral-flowmeter-technical-drawings-terminal-configuration/663031/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/integral-flowmeter-technical-drawings-terminal-configuration/663031.png","ImageObject",300,407,{"name":42,"@type":43},"Mabel","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":52,"interactionType":53,"userInteractionCount":22},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"Which communication types are covered in the terminal wiring specifications?","Question",{"text":62,"@type":63},"The document includes terminal wiring layouts for BRAIN/HART communication type and for Foundation Fieldbus/PROFIBUS PA communication type.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What electrical outputs and inputs are listed for the BRAIN/HART terminal configuration?",{"text":67,"@type":63},"It lists power supply, current output (4 to 20 mA DC), pulse/alarm/status output (DO+ / DO-), alarm/status output and status input (DIO+ / DIO-), plus functional grounding and protective grounding notes.",{"name":69,"@type":60,"acceptedAnswer":70},"How are grounding terminals handled for different communication and explosion-proof conditions?",{"text":71,"@type":63},"The drawings specify functional grounding and protective grounding outside the terminal, and include notes that for explosion-proof types the functional grounding terminal is added; indicator-related measurement adjustments are also provided.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},663031,1793224697,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":22,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":26,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":79,"read_time":96},7971474920318,"https://ap-avatar.wpscdn.com/avatar/74000ee537e6b0ca360?x-image-process=image/resize,m_fixed,w_180,h_180&k=1788430171632181674","Drawings  \nAXF002, AXF005, AXF010    \nAXF Integral Flowmeter/Remote Flowtube  \nAXF Standard (Union Joint)  \nCeramics Lining  \nIntegral Flowmeter Remote Flowtube Integral Flowmeter Remote Flowtube Unit : mm  \nGround Terminal (approx. inch)  \nHi  \n73(2.87) 49( 1 .93)  \n(M4)  \n L   \n111(4.37)   \n  4(0 . 16)  11.5  (0.45)  \n  30(1.18)   \nWeld joint    (2.83) øA øB  øC  \n􀀁58 (2.28)    4(0.16)   10  (0.39)   \n 35(1.38)   \nø 128(5.04)  \n66(2.6)*1  \nFig03E.EPS  \n*No infla-red switches are furnished for Fieldbus communication type.  \nøC  \nøD  \nøA  \n\n| Size | A | B | C | D |\n| --- | --- | --- | --- | --- |\n| 2.5\u003Cbr>(0.1) | 22(0.87) | 8(0.31) | 18.5(0.73) | R1/4 |\n|  | 22(0.87) | 8(0.31) | 18.5(0.73) | NPT1/4 |\n| 5\u003Cbr>(0.2) | 22(0.87) | 8(0.31) | 18.5(0.73) | R1/4 |\n|  | 22(0.87) | 8(0.31) | 18.5(0.73) | NPT1/4 |\n| 10\u003Cbr>(0.4) | 25(0.98) | 10(0.39) | 22.5(0.89) | R3/8 |\n|  | 25(0.98) | 10(0.39) | 22.5(0.89) | NPT3/8 |\n\n\n| Size | A | B | C | D |\n| --- | --- | --- | --- | --- |\n| 2.5(0.1) | 22(0.87) | 8(0.31) | 14.3(0.56) | 18.5(0.73) |\n| 5(0.2) | 22(0.87) | 8(0.31) | 14.3(0.56) | 18.5(0.73) |\n| 10(0.4) | 25(0.98) | 10(0.39) | 17.8(0.70) | 22.5(0.89) |\n\n(M4)  \nGround Terminal 197(7 .76)*1  \nUnion joint   D  \nFig100E.EPS  \nModel code:  \nAXF002  \nGAXF005  \nCAXF010  \n*3  \nD  \nE  \nF  \nG  \nN  \nP  \n1  \n2  \nN  \nC E 1 N ~~ ~~  \nG U  \nW  \nN  \nR  \n1  \n*3: D, E, F, G; Integral Flowmeter, N, P: Remote Flowtube  \n\n| Model | Process connection |  | GUW (Welding type) |  |  | GUN/GUR (Union joint type) |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  | Size code |  | 002 | 005 | 010 | 002 | 005 | 010 |\n|  | Size |  | 2.5 | 5 | 10 | 2.5 | 5 | 10 |\n|  |  |  | (0.1) | (0.2) | (0.4) | (0.1) | (0.2) | (0.4) |\n|  | Lining code |  | C | C | C | C | C | C |\n| Remote\u003Cbr>Flowtube Integral Flowmeter | Face-to-face\u003Cbr>length | L | 140(5.51) |  |  | 130(5.12) |  |  |\n|  | Height | H1 | 144(5.67) |  |  | 144(5.67) |  |  |\n| Remote\u003Cbr>Flowtube | Max. Height | Hr | 268(10.55) |  |  | 268(10.55) |  |  |\n|  | Weight kg (lb) |  | 2.3(5.1) |  |  | 2.3(5.1) |  |  |\n| Integral Flowmeter | Max. Height | Hi | 306(12.03) |  |  | 306(12.03) |  |  |\n|  | Weight kg (lb) |  | 4(8.8) |  |  | 4(8.8) |  |  |\n\nLining code : C; Ceramics TD01E.EPS  \n* When option code RA, RB, or RC is selected, the direction of electrical connection change as below.  \n\n|  | Standard |  |  | +90-degree\u003Cbr>rotation | +180-degree\u003Cbr>rotation | -90-degree\u003Cbr>rotation |\n| --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  | RA | RB | RC |\n| Integral\u003Cbr>Flowmeter | |  |  | | | |\n| Remote\u003Cbr>Flowtube |  |  |  | | | |\n|  |  | |  |  |  |  |\n\nF19-1E.EPS  \n*1: When indicator code N is selected, subtract 12mm(0.47inch) from the value in the figure. In case of explosion proof type with indicator, add 5 mm (0.2 inch) to it.  \nUnless otherwise specified, difference in the dimensions are specified as : General tolerance = ± (Criteria of tolerance class IT18 in JIS B0401) / 2  \nYokogawa Electric Corporation  \nAll Right Reserved, Copyright c 2003, Yokogawa Electric Corporation Subject to change without notice. Printed in Japan.  \nP-  \nSD 01E20D02-01E 1/2 7th Edition : Feb. 13, 2008  \nIntegral Flowmeter  \nBRAIN/HART Communication Type  \nTerminal configuration Terminal wiring  \n| Teminal\u003Cbr>Symbols | Description |  |\n| --- | --- | --- |\n|  | Functional grounding |  |\n| N/ -\u003Cbr>L/+ |  | Power supply |\n| I+\u003Cbr>I- |  | Current output 4 to 20mA DC |\n| DO+\u003Cbr>DO- |  | Pulse output/Alarm output/ Status output |\n| DIO+\u003Cbr>DIO- |  | Alarm output/Status output Status input |\n|  | Protective grounding (Outside of the terminal) |  |\n\nFig01-2E.EPS  \nRemote Flowtube  \nTerminal configuration  \nTerminal wiring  \n\n| Teminal\u003Cbr>Symbols | Description |  |\n| --- | --- | --- |\n| A | |  |\n| B |  | Flow signal output |\n| C | |  |\n| EX1\u003Cbr>EX2 | | Excitation current input |\n| | Protective grounding (Outside of the terminal) |  |\n\n*2: In case of explosion proof type,  (functional grounding terminal) is added. Fig02E. EPS  \nFOUN","cbCaifzZlMQNN7rf","https://ap.wps.com/l/cbCaifzZlMQNN7rf","pdf",98890,"English","# Terminal configuration\n## BRAIN/HART Communication Type\n## Foundation Fieldbus/PROFIBUS PA Communication Type","[{\"question\":\"Which communication types are covered in the terminal wiring specifications?\",\"answer\":\"The document includes terminal wiring layouts for BRAIN/HART communication type and for Foundation Fieldbus/PROFIBUS PA communication type.\"},{\"question\":\"What electrical outputs and inputs are listed for the BRAIN/HART terminal configuration?\",\"answer\":\"It lists power supply, current output (4 to 20 mA DC), pulse/alarm/status output (DO+ / DO-), alarm/status output and status input (DIO+ / DIO-), plus functional grounding and protective grounding notes.\"},{\"question\":\"How are grounding terminals handled for different communication and explosion-proof conditions?\",\"answer\":\"The drawings specify functional grounding and protective grounding outside the terminal, and include notes that for explosion-proof types the functional grounding terminal is added; indicator-related measurement adjustments are also provided.\"}]","Integral Flowmeter - Technical Drawings - Terminal Configuration | PDF"]