[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-641085-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-641085-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","instructions-parts-list-hvlpturbine-guns","INSTRUCTIONS - PARTS LIST - HVLP–Turbine Guns","","Instructions and parts list for Graco HVLP turbine guns, including model configurations for cup feed and remote pressure feed with specified maximum inlet air and fluid pressures. The manual provides critical safety warnings covering fire and explosion risks, proper grounding, ventilation, distance from vapor hazards, and safe operating practices. It also includes equipment misuse cautions and toxic fluid hazard guidance, followed by an introduction outlining key features, controls, and general operating instructions.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/instructions-parts-list-hvlpturbine-guns/641085/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/instructions-parts-list-hvlpturbine-guns/641085.png","ImageObject",300,407,{"name":42,"@type":43},"Bintang","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-27","2026-10-22",true,{"@type":52,"interactionType":53,"userInteractionCount":33},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What is the maximum inlet air and fluid pressure for the HVLP turbine guns?","Question",{"text":62,"@type":63},"Maximum inlet air pressure is 10 psi (0.07 MPa, 0.7 bar). Maximum inlet fluid pressure is 50 psi (0.35 MPa, 3.5 bar).","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What fire and explosion precautions are required before operating?",{"text":67,"@type":63},"The manual warns about improper grounding, poor ventilation, open flames or sparks. It instructs grounding the equipment, ensuring fresh air ventilation, keeping the turbine at least 20 feet from likely flammable vapor concentrations, and not using the equipment inside a spray booth.",{"name":69,"@type":60,"acceptedAnswer":70},"What toxic fluid precautions must be followed?",{"text":71,"@type":63},"Hazardous fluid or toxic fumes can cause serious injury or death if splashed, inhaled, or swallowed. The manual instructs knowing the fluid hazards, using approved containers and proper disposal, wearing protective eyewear, gloves, clothing, and respirator as recommended, and avoiding certain halogenated hydrocarbon solvents in the turbine spray system.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},641085,1793008327,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":33,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":98},962085564381,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","INSTRUCTIONS–PARTS LIST  \n\n| | This manual contains important warnings and information.\u003Cbr>READ AND KEEP FOR REFERENCE. |\n| --- | --- |\n| INSTRUCTIONS |  |\n\n309205  \nRev. D  \nParts  \nUS Patent Pending  \nHVLP–Turbine Guns  \n10 psi (0.07 MPa, .7 bar) Maximum Inlet Air Pressure  \n50 psi (0.35 MPa, 3.5 bar) Maximum Inlet Fluid Pressure  \nCup Feed  \nIncludes 1-quart (1 liter) cup Model 244113, without fluid set Model 244117, with \\# 3 fluid set  \nT10746  \nRemote Pressure Feed  \nModel 244115, without fluid set Model 244118, with \\# 3 fluid set  \nGRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441  \n􀀁COPYRIGHT 2000, GRACO INC.  \nGraco [Inc. is](Inc. is) registered to I.S. EN ISO 9001  \nTable of Contents  \nWarnings ..................................... 2  \nIntroduction .................................... 4  \nSpraying Techniques ........................... 12  \nMaintenance .................................. 14  \nService ...................................... 17  \nTroubleshooting ............................... 19  \nAccessories .................................. 21  \nTechnical Data ................................ 21  \nParts ........................................ 23  \nGraco Standard Warranty ...................... 24  \nGraco Phone Number .......................... 24  \nSymbols  \nWarning Symbol  \nWARNING  \nThis symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.  \nCaution Symbol  \n CAUTION  \nThis symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.  \n\n|  | WARNING |\n| --- | --- |\n| \u003Cbr>| FIRE AND EXPLOSION HAZARD\u003Cbr>Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.\u003Cbr>􀀂 Ground the equipment.\u003Cbr>􀀂 If there is any static sparking or you feel an electric shock while using this equipment, stopspraying immediately. Do not use the equipment until you identify and correct the problem.\u003Cbr>􀀂 Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed.\u003Cbr>􀀂 When flammable liquid is sprayed or used for flushing or cleaning the equipment, the turbine must be placed at least 20 feet (6.1 m) away from areas where hazardous concentrations of flammable vapors are likely to occur.\u003Cbr>􀀂 Use additional air hose if necessary to ensure that the turbine is operated in a clean, dry, well ventilated area.\u003Cbr>􀀂 Never place the turbine inside a spray booth! Use this equipment outdoors or in extremely well ventilated areas.\u003Cbr>􀀂 Keep the spray area free of debris, including solvent, rags, and gasoline.\u003Cbr>􀀂 Electrically disconnect all equipment in the spray area.\u003Cbr>􀀂 Extinguish all open flames or pilot lights in the spray area.\u003Cbr>􀀂 Do not smoke in the spray area.\u003Cbr>􀀂 Do not turn on or off any light switch in the spray area while operating or if fumes are present.\u003Cbr>􀀂 Do not operate a gasoline engine in the spray area. |\n| |  |\n\n|  | WARNING |\n| --- | --- |\n| \u003Cbr>INSTRUCTIONS | EQUIPMENT MISUSE HAZARD\u003Cbr>Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.\u003Cbr>􀀂 This equipment is for professional use only.\u003Cbr>􀀂 Read all instruction manuals, tags, and labels before operating the equipment.\u003Cbr>􀀂 Use the equipment only for its intended purpose. If you are not sure, call your distributor.\u003Cbr>􀀂 Do not alter or modify this equipment. Use only genuine Graco parts and accessories.\u003Cbr>􀀂 Check equipment daily. Repair or replace worn or damaged parts immediately.\u003Cbr>􀀂 Do not exceed the maximum working pressure of the lowest rated system component. See the Technical Data on page 21.\u003Cbr>􀀂 Use fluids and solvents that are compatible with the equipment wetted parts. Refer to the Technical Data on page 21 for wetted parts.\u003Cbr>􀀂 Do not use hoses to pull equipment.\u003Cbr>􀀂 Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses ","cbCaifeGF7jb2ibR","https://ap.wps.com/l/cbCaifeGF7jb2ibR","pdf",507373,24,"English","# Warnings\n# Introduction\n## Features\n# Spraying Techniques\n# Maintenance\n# Service\n# Troubleshooting\n# Accessories\n# Technical Data\n# Parts\n# Graco Standard Warranty\n# Graco Phone Number","[{\"question\":\"What is the maximum inlet air and fluid pressure for the HVLP turbine guns?\",\"answer\":\"Maximum inlet air pressure is 10 psi (0.07 MPa, 0.7 bar). Maximum inlet fluid pressure is 50 psi (0.35 MPa, 3.5 bar).\"},{\"question\":\"What fire and explosion precautions are required before operating?\",\"answer\":\"The manual warns about improper grounding, poor ventilation, open flames or sparks. It instructs grounding the equipment, ensuring fresh air ventilation, keeping the turbine at least 20 feet from likely flammable vapor concentrations, and not using the equipment inside a spray booth.\"},{\"question\":\"What toxic fluid precautions must be followed?\",\"answer\":\"Hazardous fluid or toxic fumes can cause serious injury or death if splashed, inhaled, or swallowed. The manual instructs knowing the fluid hazards, using approved containers and proper disposal, wearing protective eyewear, gloves, clothing, and respirator as recommended, and avoiding certain halogenated hydrocarbon solvents in the turbine spray system.\"}]","INSTRUCTIONS - PARTS LIST - HVLP–Turbine Guns | PDF",1792712692]