[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646609-105":59,"doc-detail-646609-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","instruction-manual-dosing-g-pump-series","Instruction Manual - Dosing G pump Series","","Instruction manual for installing, operating, and maintaining the Dosing G pump in the “SERIES G” model, including the GA DSD liquid end. It provides structured guidance from unpacking, storage precautions, and pump description through hydraulic, electrical, and handling installation, then startup procedures, failure handling, and scheduled checks. It further covers routine maintenance, preventive annual overhaul, corrective maintenance, and servicing of the liquid end and mechanical assembly, including conformity declaration and guarantee information.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/instruction-manual-dosing-g-pump-series/646609/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/instruction-manual-dosing-g-pump-series/646609.png","ImageObject",300,407,{"name":92,"@type":93},"Emma Wilson","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-28","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What should be done with the pump packaging upon receipt?","Question",{"text":112,"@type":113},"Examine the packaging carefully on receipt to ensure no obvious damage. Take precautions when opening to avoid damaging accessories secured inside, then check contents against the delivery note.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the pump adjust capacity during operation or when stopped?",{"text":117,"@type":113},"Capacity adjustment is controlled either manually using a stroke adjustment knob or automatically via a control box, depending on the version such as a G VARIPULSE single-phase motor.",{"name":119,"@type":110,"acceptedAnswer":120},"What safety steps are required before servicing?",{"text":121,"@type":113},"Perform any servicing only when the equipment is stopped and prevent any accidental start-up, for example by locking the switch or removing the fuse on the power supply line. Attach a notice at the switch location indicating servicing is in progress.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646609,1793030165,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},3848291630094,"https://eur-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","INSTRUCTION MANUAL  \nFOR INSTALLATION OPERATING, AND MAINTENANCE.  \nDosing G pump ® GA DSD liquid end  \nThis manual should be made available to the person responsible for installation, operating and  \nmaintenance.  \nTranslated version  \nDATE : 03/12/2015 REV : 00  \nCONTENTS  \nI – DESCRIPTION  \nI - 1. Unpacking and storage  \nI -2. Description  \nI -3. Operating principle of the pump  \nI -4. Accessories  \nI -5. Safety and health instructions  \nII – INSTALLATION  \nII -1. Hydraulic installation  \nII -2. Drip collection  \nII -3. Handling  \nII -4. Setting up  \nII -5. Electrical installation  \nIII -START UP  \nIII -1. Procedures before start up  \nIII -2. Start up  \nIII -3. Failures on start up  \nIII -4. Operation-Schedule of checks and maintenance operations  \nIV-ROUTINE MAINTENANCE  \nIV-1. Checking the pump capacity  \nIV-2. Tracing causes of failure  \nIV-3. Ordering spare parts  \nV-PREVENTIVE MAINTENANCE-ANNUAL OVERHAUL  \nV-1. Spare parts required for annual overhaul  \nV-2. Sequential actions  \nVI -CORRECTIVE MAINTENANCE  \nVI - 1. List of other spare parts  \nVI -2 Sequential actions  \nVII -SERVICING THE LIQUID END AND THE LIQUID END MOUNTING ASSEMBLY  \nVII -1. General and procedures  \nVIII -SERVICING THE MECHANICAL ASSEMBLY  \nVIII -1 General  \nVIII -2 Dismantling, Reinstalling the mechanical assembly  \n« EC » DECLARATION OF CONFORMITY  \nGUARANTEE  \nLIST OF « TECHNICAL ASSISTANCE » AND « SPARE PARTS » DEPARTMENTS  \nPART I -DESCRIPTION  \nI - 1. UNPACKING AND STORAGE  \nUNPACKING  \nThe packaging must be carefully examined on receipt in order to ensure that the contents have not sustained any obvious damage. Precautions must be taken when opening the packaging in order to avoid damaging accessories which may be secured inside the packaging. Examine the contents and check them off against the delivery note.  \nSTORAGE PRECAUTIONS  \nStorage for less than six months  \nEquipment shall preferably be stored in its original packaging and protected from adverse weather conditions.  \nStorage for more than six months  \n􀁸 Store the pump in its original packaging. In addition, packaging in heat-sealing plastic cover and dessicant bags must be provided for. The quantity of dessicant bags should be adapted to the storage period and to the packaging volume.  \n􀁸 Store protected from adverse weather conditions.  \nI -2. DESCRIPTION  \nThe « SERIES G » Model A pump is a compact electromechanical metering pump that is life-lubricated with oil in a sealed housing, with capacity adjustment in operation or when stopped.  \nIt is made up of the following components (Fig. 1.2a):  \n* a drive device comprising a motor [1],* a mechanical assembly [2],* a liquid end [3] .  \n\n| | | |\n| --- | --- | --- |\n| 1 Motor 8 Stroke locking device 2 Mechanical assembly 9 Leak detection port 3 Liquid end 10 4-function valve * 4 Stroke adjustment knob 11 Valve assembly (suction) 5 Control unit (frequency control) 12 Valve assembly (discharge) 6 Liquid end mounting assembly\u003Cbr>* Accessory supplied as optional equipment with pumps equipped with plastic liquid end \u003C22 l/h.\u003Cbr>Fig. 1.2a: Model A, series G pump |  |  |\n\n*  \nLeak-tightness between the mechanical assembly and the liquid end is ensured by means of a bellows.  \nCapacity adjustment is controlled either manually (by a stroke adjustment knob [4]) or automatically by a control box [5] (such as in the case of a G VARIPULSE version single-phase motor) .  \nVarious components of the pump are shown in Figure 1.2a.  \nNote: For further information on the automatic control system, see the relevant specific manual.  \nI -3. OPERATING PRINCIPLE OF THE PUMP  \nSee Figures 1 .3b and 1 .3c.  \nFig. 1.3b : Setting to zero stroke  \nSuction phase Discharge phase  \nFig. 1.3c : Setting to maximum stroke  \n\n| 1 | Worm | 4 | Connecting rod |\n| --- | --- | --- | --- |\n| 2 | Tangential wheel | 6 | Crosshead |\n| 3 | Eccentric | 7 | Diaphragm |\n\nMECHANICAL ASSEMBLY  \nThe mechanical assembly works on the principle of a variable eccentric.  \nThe rotational mo","cbCaitAiYcEJL1BW","https://ap.wps.com/l/cbCaitAiYcEJL1BW","pdf",2092104,39,"English","# Contents\n## I – Description\n## I - 1. Unpacking and storage\n## I -2. Description\n## I -3. Operating principle of the pump\n## I -4. Accessories\n## I -5. Safety and health instructions\n## II – Installation\n## II -1. Hydraulic installation\n## II -2. Drip collection\n## II -3. Handling\n## II -4. Setting up\n## II -5. Electrical installation\n## III – Start up\n## III -1. Procedures before start up\n## III -2. Start up\n## III -3. Failures on start up\n## III -4. Operation-Schedule of checks and maintenance operations\n## IV -Routine Maintenance\n## IV-1. Checking the pump capacity\n## IV-2. Tracing causes of failure\n## IV-3. Ordering spare parts\n## V-Preventive Maintenance-Annual Overhaul\n## V-1. Spare parts required for annual overhaul\n## V-2. Sequential actions\n## VI -Corrective Maintenance\n## VI - 1. List of other spare parts\n## VI -2 Sequential actions\n## VII -Servicing the Liquid End and the Liquid End Mounting Assembly\n## VII -1. General and procedures\n## VIII -Servicing the Mechanical Assembly\n## VIII -1 General\n## VIII -2 Dismantling, Reinstalling the mechanical assembly\n## EC Declaration of Conformity\n## Guarantee\n## Technical Assistance and Spare Parts Departments","[{\"question\":\"What should be done with the pump packaging upon receipt?\",\"answer\":\"Examine the packaging carefully on receipt to ensure no obvious damage. Take precautions when opening to avoid damaging accessories secured inside, then check contents against the delivery note.\"},{\"question\":\"How does the pump adjust capacity during operation or when stopped?\",\"answer\":\"Capacity adjustment is controlled either manually using a stroke adjustment knob or automatically via a control box, depending on the version such as a G VARIPULSE single-phase motor.\"},{\"question\":\"What safety steps are required before servicing?\",\"answer\":\"Perform any servicing only when the equipment is stopped and prevent any accidental start-up, for example by locking the switch or removing the fuse on the power supply line. Attach a notice at the switch location indicating servicing is in progress.\"}]","Instruction Manual - Dosing G pump Series | PDF",1792764647,98]