[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-652751-105":59,"doc-detail-652751-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","ingersoll-rand-ss5l5ss5n5-single-stage-compressor-owners-manual-with-parts-list","Ingersoll Rand SS5L5/SS5N5 Single-Stage Compressor Owner’s Manual With Parts List","","Owner’s manual covering the Ingersoll Rand SS5L5 and SS5N5 single-stage air compressor. Provides safety guidance and hazard warnings, general precautions, and key operating, installation, and maintenance procedures. Includes instructions for selecting a location, routing inlet and discharge piping, electrical wiring basics, lubrication requirements, filling and initial start-up steps, filter and oil change guidance, and troubleshooting overview. Also contains warranty and limitation of liability information and a parts list with kits and accessories.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/ingersoll-rand-ss5l5ss5n5-single-stage-compressor-owners-manual-with-parts-list/652751/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/ingersoll-rand-ss5l5ss5n5-single-stage-compressor-owners-manual-with-parts-list/652751.png","ImageObject",300,407,{"name":92,"@type":93},"Anna Hans","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What safety precautions are emphasized before servicing the compressor?","Question",{"text":112,"@type":113},"The manual warns that a hazardous voltage can cause serious injury or death. Disconnect power and bleed tank pressure, and follow lockout/tagout requirements before servicing.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What guidance is given for installing inlet and discharge piping?",{"text":117,"@type":113},"It instructs planning for remote air inlet piping and discharge piping during installation. It also lists general requirements and condensate discharge piping considerations.",{"name":119,"@type":110,"acceptedAnswer":120},"What maintenance tasks are recommended for the SS5 model?",{"text":121,"@type":113},"Maintenance includes filter replacement for SS5, oil change procedures, belt adjustment, and tank inspections, followed by troubleshooting if issues occur.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},652751,1793030184,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":26},5909892332657,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","RELEASED 05/Apr/2018 15:16:08 GMT  \n22204945  \nRevision C March 2018  \nSS5L5  \nSS5N5  \nOwner’s Manual With Parts List  \nEN Owner’s Manual With Parts List  \nES Manual del propietario con la lista de piezas FR Manuel du propriétaire avec liste des pièces  \nSave These Instructions  \nCONTENTS  \nSAFETY ...................................... 4  \nGENERAL SAFETY PRECAUTIONS ................ 4  \nGENERAL INFORMATION ...................... 4  \nRECEIPT & INSPECTION ....................... 5  \nINSTALLATION ............................... 6  \nSELECTING A LOCATION ...............................6  \nGENERAL .............................................6  \nTEMPERATURE ........................................6  \nHUMID AREAS ........................................6  \nNOISE CONSIDERATIONS ..............................6  \nPERMANENT MOUNTING..............................6  \nTypical Permanent Mounting (Customer-Supplied Hardware) ............................................6  \nINSTALLING REMOTE AIR INLET PIPING ................6  \nINSTALLING DISCHARGE PIPING.................6  \nGENERAL REQUIREMENTS ...................... 7  \nCONDENSATE DISCHARGE PIPING ............... 7  \nELECTRICAL WIRING ............................ 7  \nGENERAL .............................................7  \nWIRE SIZE .............................................7  \nFUSES ................................................7  \nCOMPRESSOR LUBRICATION .................... 7  \nSYNTHETIC COMPRESSOR LUBRICANT .................7  \nALTERNATE LUBRICANTS ..............................7  \nFILLING PROCEDURES:.................................8  \nINITIAL START-UP......................................8  \nPRESSURE SWITCH ....................................8  \nOPERATION .................................. 9  \nGENERAL .............................................9  \nNORMAL START-UP ....................................9  \nWHEN YOU ARE FINISHED: .............................9  \nMAINTENANCE .............................. 10  \nFILTER REPLACEMENT (SS5) .................... 10  \nOIL CHANGE ........................................ 10  \nBELT ADJUSTMENT .................................. 11  \nTANK INSPECTION ................................... 11  \nTROUBLESHOOTING ......................... 12  \nWARRANTY AND LIMITATION OF LIABILITY .... 16  \nWARRANTY ................................... 16  \nLIMITATION OF LIABILITY ...................... 16  \nPARTS LIST ................................. 20  \nKITS & ACCESSORIES ......................... 22  \nEXTENDED WARRANTY KIT........................... 22  \nINGERSOLL RAND SYNTHETIC LUBRICANT............ 22  \nELEMENT0 DE FILTRO DE AlRE ....................... 22  \nSTEP SAVER KITS..................................... 22  \nCRANKCASE HEATER KIT ............................. 22  \nMULTIPURPOSE AIR HOSES .......................... 22  \nY-STRAINERS ....................................... 22  \nMay 2015  \nEN  \nRELEASED 05/Apr/2018 15:16:08 GMT  \nSAFETY  \nIndicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.  \nIndicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.  \nIndicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or property damage. Indicates information or a company policy that relates directly or indirectly to the safety of personnel or protection of property.  \n􀂄 GENERAL SAFETY PRECAUTIONS  \n\n|  |  |  |  |\n| --- | --- | --- | --- |\n|  |  | 􀀂􀀁􀀅􀀄􀀃􀀆 |  |\n|  |  |  |  |\n| Intake air can contain carbon monoxide or other contaminants. Will cause serious injury or death. Ingersoll Rand air compressors are not designed, intended or approved for breathing air. Compressed air should not be used for breathing air applications unless treated in accordance with all applicable codes and regulations. |  |  |  |\n\n|  |  |  |  |\n| --- | --- | --- | --- |\n|  |  | WARNING |  |\n|  |  |  |  |\n| A hazardous voltage can cause serious injury or ","cbCainrAyRvc5Fvh","https://ap.wps.com/l/cbCainrAyRvc5Fvh","pdf",331610,24,"English","# Safety\n## General Safety Precautions\n# General Information\n# Receipt & Inspection\n# Installation\n## Selecting a Location\n## General\n## Temperature\n## Humid Areas\n## Noise Considerations\n## Permanent Mounting\n## Installing Remote Air Inlet Piping\n## Installing Discharge Piping\n# Operation\n## General\n## Normal Start-Up\n## When You Are Finished\n# Maintenance\n## Filter Replacement (SS5)\n## Oil Change\n## Belt Adjustment\n## Tank Inspection\n# Troubleshooting\n# Warranty and Limitation of Liability\n# Parts List\n## Kits & Accessories","[{\"question\":\"What safety precautions are emphasized before servicing the compressor?\",\"answer\":\"The manual warns that a hazardous voltage can cause serious injury or death. Disconnect power and bleed tank pressure, and follow lockout/tagout requirements before servicing.\"},{\"question\":\"What guidance is given for installing inlet and discharge piping?\",\"answer\":\"It instructs planning for remote air inlet piping and discharge piping during installation. It also lists general requirements and condensate discharge piping considerations.\"},{\"question\":\"What maintenance tasks are recommended for the SS5 model?\",\"answer\":\"Maintenance includes filter replacement for SS5, oil change procedures, belt adjustment, and tank inspections, followed by troubleshooting if issues occur.\"}]","Ingersoll Rand SS5L5/SS5N5 Single-Stage Compressor Owner’s Manual With Parts List | PDF",1792882367]