[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-378574-105":59,"doc-detail-378574-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","in-vivo-detection-of-bile-duct-pre-cancer-with-endoscopic-light-scattering-spectroscopy","In vivo detection of bile duct pre-cancer with endoscopic light scattering spectroscopy","","Bile duct cancer, often diagnosed at advanced stages, has poor survival outcomes, creating an urgent need for reliable in vivo detection of pre-cancer. Radiological imaging cannot distinguish dysplastic from benign biliary ducts with sufficient accuracy, while conventional endoscopic sampling methods have limited sensitivity. This work reports an endoscopic optical light scattering approach using an ultraminiature spatial-gating fiber-optic probe compatible with cholangioscopes and ERCP, combining light scattering spectroscopy and diffuse reflectance spectroscopy. In a pilot double-blind prospective study of 29 patients, the technique identified malignant transformation with 97% accuracy, enabling noninvasive pre-cancer detection.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/in-vivo-detection-of-bile-duct-pre-cancer-with-endoscopic-light-scattering-spectroscopy/378574/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/in-vivo-detection-of-bile-duct-pre-cancer-with-endoscopic-light-scattering-spectroscopy/378574.png","ImageObject",300,407,{"name":92,"@type":93},"RuangKosong","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-23","2026-09-24",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",16,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"Why is detecting bile duct pre-cancer urgently needed?","Question",{"text":113,"@type":114},"Most bile duct cancer diagnoses occur in advanced stages, leading to poor survival. Reliable identification of pre-cancer is needed to enable earlier intervention.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What are the main limitations of existing diagnostic approaches?",{"text":118,"@type":114},"Radiological imaging has inadequate accuracy for distinguishing dysplastic from benign ducts. Endoscopic methods can directly assess the lining but often suffer from insufficient sampling, reducing sensitivity.",{"name":120,"@type":111,"acceptedAnswer":121},"How does the reported technique work and what did the pilot study show?",{"text":122,"@type":114},"The method uses an ultraminiature spatial-gating fiber-optic probe in endoscopic settings, applying light scattering spectroscopy to assess epithelial cellular composition and diffuse reflectance spectroscopy for underlying connective tissue. In a 29-patient pilot double-blind prospective study, it detected malignant transformation with 97% accuracy and enabled noninvasive in vivo identification of pre-cancer.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},378574,1790292524,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":41,"preview_page_count":19,"preview_urls":146},962090883219,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Article [https://doi.org/10.1038/s41467-022-35780-7](https://doi.org/10.1038/s41467-022-35780-7)  \nIn vivo detection of bile duct pre-cancer with endoscopic light scattering spectroscopy  \nReceived: 23 February 2021  \n\n| Accepted: 23 December 2022 |\n| --- |\n| |\n| Check for updates |\n\nDouglas K. Pleskow 1,2,4, Mandeep S. Sawhney2,4, Paul K. Upputuri1,4,  \nTyler M. Berzin 2,4, Mark F. Coughlan 1, Umar Khan1, Maria Glyavina1, Xuejun Zhang1, Liming Chen1, Conor J. Sheil1, Jonah M. Cohen2, Edward Vitkin1, Yuri N. Zakharov 1, Irving Itzkan1, Lei Zhang 1 , Le Qiu 1  &  \nLev T. Perelman 1,3   \nBile duct cancer is the second most common primary liver cancer, with most diagnoses occurring in the advanced stages. This leads to a poor survival rate, which means a technique capable of reliably detecting pre-cancer in the bile duct is urgently required. Unfortunately, radiological imaging lacks adequate accuracy for distinguishing dysplastic and benign biliary ducts, while endoscopic techniques, which can directly assess the bile duct lining, often suffer from insufﬁcient sampling. Here, we report an endoscopic optical light scattering technique for clinical evaluation of the malignant potential of the bile duct. This technique employs an ultraminiature spatial gatingﬁber optic probe compatible with cholangioscopes and endoscopic retrograde cholangiopancreatography (ERCP) catheters. The probe allowed us to investigate the internal cellular composition of the bile duct epithelium with light scattering spectroscopy (LSS) and phenotypic properties of the underlying connective tissue with diffuse reﬂectance spectroscopy (DRS). In a pilot in vivo doubleblind prospective study involving 29 patients undergoing routine ERCP procedures, the technique detected malignant transformation with 97% accuracy, showing that biliary duct pre-cancer can be reliably identiﬁed in vivo noninvasively.  \nBile duct cancer, also known as cholangiocarcinoma, is characteristically diagnosed late as most people have no identiﬁable risk factors1,2 for this cancer, resulting in poor outcomes3. The only possible treatment options for early-stage cholangiocarcinoma are liver transplantation or surgery before cancer cells spread outside the liver. Even when surgery is successful, the median survival period is ~2 years, depending on the extent of the disease4. Because of the poor prognosis, a technique capable of reliably detecting pre-cancer of the bile duct is urgently needed5.  \nEarly detection of cholangiocarcinoma is challenging not only because of its asymptomatic character and anatomically hard-to-access location, but also due to low speciﬁcity of most diagnostic modalities6. Radiological imaging methods, such as ultrasound (US), X-ray computed tomography (CT), magnetic resonance cholangiopancreatography (MRCP), or positron emission tomography–computed tomography (PET-CT) are currently used for the detection of cholangiocarcinoma. However, these imaging modalities are known to suffer from low speciﬁcity and accuracy7.  \n1Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard University, Boston, MA, USA. 2Center for Advanced Endoscopy, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard University, Boston, MA, USA. 3Biological and Biomedical Sciences Program, Harvard University, Boston, MA, USA. 4These authors contributed  \nequally: Douglas K. Pleskow, Mandeep S. Sawhney, Paul K. Upputuri, Tyler M. Berzin. e-mail: [lzhang11@bidmc.harvard.edu](lzhang11@bidmc.harvard.edu); [lqiu@bidmc.harvard.edu](lqiu@bidmc.harvard.edu);  \n[lperelman@fas.harvard.edu](lperelman@fas.harvard.edu)  \nUnlike radiological imaging, endoscopic techniques allow direct tissue investigation. They can detect structural changes in multiple toplayers of the bile duct during early tumor development, thereby improving sensitivity. For example, endoscopic retro","cbCaisDqoTX5QG3t","https://ap.wps.com/l/cbCaisDqoTX5QG3t","pdf",1771604,12,"English","# Background\n## Clinical need for early detection\n## Limits of radiological imaging\n## Limits of conventional endoscopic sampling\n# Related optical and endoscopic methods\n## Narrow-band imaging (NBI)\n## Probe-based confocal laser endomicroscopy (pCLE)\n## Optical coherence tomography (OCT)\n# Endoscopic light scattering spectroscopy approach\n## Probe design and compatibility\n## Measurement modalities (LSS and DRS)\n## Pilot in vivo prospective evaluation","[{\"question\":\"Why is detecting bile duct pre-cancer urgently needed?\",\"answer\":\"Most bile duct cancer diagnoses occur in advanced stages, leading to poor survival. Reliable identification of pre-cancer is needed to enable earlier intervention.\"},{\"question\":\"What are the main limitations of existing diagnostic approaches?\",\"answer\":\"Radiological imaging has inadequate accuracy for distinguishing dysplastic from benign ducts. Endoscopic methods can directly assess the lining but often suffer from insufficient sampling, reducing sensitivity.\"},{\"question\":\"How does the reported technique work and what did the pilot study show?\",\"answer\":\"The method uses an ultraminiature spatial-gating fiber-optic probe in endoscopic settings, applying light scattering spectroscopy to assess epithelial cellular composition and diffuse reflectance spectroscopy for underlying connective tissue. In a 29-patient pilot double-blind prospective study, it detected malignant transformation with 97% accuracy and enabled noninvasive in vivo identification of pre-cancer.\"}]","In vivo detection of bile duct pre-cancer with endoscopic light scattering spectroscopy | PDF",1790231236,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/339a293485ac39941f1541b8f0ee8d92.webp",983,1305,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/e762dd0efc26da62ec4a64c562063d05.webp",982,1304,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/08b342f351966a7f4c64309c35b1c0b9.webp",981,1303,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/ec11e5f78be8b347c6020b6f9bd0a6e8.webp",980,1301]