[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-466266-105":59,"doc-detail-466266-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","in-situ-dose-measurements-in-brachytherapy-using-scintillation-detectors-based-on-the-al2o3c-al2o3cmg-and-gaggce-crystals","In Situ Dose Measurements in Brachytherapy Using Scintillation Detectors Based on the Al2O3:C, Al2O3:C,Mg, and GAGG:Ce Crystals","","Currently, fiber-optic dosimeters using scintillation crystals coupled to a luminescence spectrometer provide a promising route for real-time dosimetric measurements during brachytherapy with gamma-ray sources. This study assesses the feasibility of fiber-optic dosimeters for in situ dose measurements in brachytherapy using Al2O3:C and Al2O3:C,Mg crystals, with near-tissue density and effective atomic number, and heavy GAGG:Ce scintillation crystals. Delivered dose was quantified from radioluminescence measured via long optical fibers and compact spectrometers. Experiments used a dedicated phantom under clinical conditions at the Oncology Center in Bydgoszcz, Poland, for a 192Ir source across 0.5–8 Gy. Results show clear linear dose–response: Gd3Al2.5Ga2.5O12:Ce performed with excellent linearity, while sapphire and co-doped Al2O3 also showed near-linear behavior.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/in-situ-dose-measurements-in-brachytherapy-using-scintillation-detectors-based-on-the-al2o3c-al2o3cmg-and-gaggce-crystals/466266/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/in-situ-dose-measurements-in-brachytherapy-using-scintillation-detectors-based-on-the-al2o3c-al2o3cmg-and-gaggce-crystals/466266.png","ImageObject",300,407,{"name":92,"@type":93},"Cart","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What is the goal of this study on fiber-optic dosimeters in brachytherapy?","Question",{"text":113,"@type":114},"To evaluate the applicability of fiber-optic dosimeters for in situ dose measurements during brachytherapy procedures using specific scintillation crystals and long optical fibers.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How was the radiation dose assessed in the experiments?",{"text":118,"@type":114},"Radiation dose delivery was determined by measuring the radioluminescence produced by the scintillation crystals, recorded through highly sensitive, compact luminescence spectrometers.",{"name":120,"@type":111,"acceptedAnswer":121},"What radiation source and dose range were used for the in situ monitoring?",{"text":122,"@type":114},"A 192Ir source (392 keV) was used, and dosimeters were evaluated for in situ dose monitoring within the 0.5–8 Gy range.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},466266,1790812454,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},18829141979164,"https://eur-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","Article  \nIn Situ Dose Measurements in Brachytherapy Using Scintillation Detectors Based on the Al2 O3:C, Al 2O3:C,Mg, and  \nGAGG:Ce Crystals  \nSandra Witkiewicz-Lukaszek 1,*, Janusz Winiecki 2,3, *, Bogna Sobiech 2, Mark Akselrod 4 and Yuriy Zorenko 1,2, *  \nAcademic Editors: Marco Girolamiand Tien-Chang Lu  \nReceived: 21 September 2025  \nRevised: 2 December 2025  \nAccepted: 3 December 2025  \nPublished: 22 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 Faculty of Physics, Kazimierz Wielki University in Bydgoszcz, Powsta ´nców Wielkopolskich Street 2, 85-090 Bydgoszcz, Poland  \n2 Franciszek Łukaszyk Oncology Center, Medical Physics Department, dr Izabeli Romanowskiej Street 2, 85-796 Bydgoszcz, Poland; [sobiechb@co.bydgoszcz.pl](sobiechb@co.bydgoszcz.pl)  \n3 Department of Oncology and Brachytherapy, Collegium Medicum in Bydgoszcz Nicholas Copernicus University in Toru ´n, Jagiello ´nska Street 13/15, 85-067 Bydgoszcz, Poland  \n4 Department of Physics, Oklahoma State University, 145 Physical Sciences Building, Stillwater, OK 74078, USA; [akselrod.mark@gmail.com](akselrod.mark@gmail.com)  \n* Correspondence: [sandra.witkiewicz-lukaszek@ukw.edu.pl or](sandra.witkiewicz-lukaszek@ukw.edu.pl or) [s-witkiewicz@wp.pl](s-witkiewicz@wp.pl) (S.W.-L.); [janusz@co.bydgoszcz.pl](janusz@co.bydgoszcz.pl) (J.W.); [zorenko@ukw.edu.pl](zorenko@ukw.edu.pl) (Y.Z.)  \nAbstract  \nCurrently, the use of scintillation crystals connected via optical fiber to a luminescence spectrometer (so-called fiber-optic dosimeters) offers a promising approach for real-timedosimetric measurements during brachytherapy treatments with γ-ray sources. This study aims to evaluate the applicability of fiber-optic dosimeters for in situ dose measurements during brachytherapy procedures, using Al 2O3 :C and Al2O3:C,Mg crystals, which have near-tissue density and effective atomic number (ρ = 3.99 g/cm3, Zeff = 10.8), as well as heavy GAGG:Ce scintillation crystals (ρ = 6.63 g/cm3, Zeff = 54.4) . Radiation dose delivery was assessed through measurements of the resulting radioluminescence of the aforementioned scintillation crystals, connected via long optical fibers and recorded with highly sensitive, compact luminescence spectrometers. Measurements were performed in a dedicated phantom under clinical conditions at the Oncology Center in Bydgoszcz, Poland. The dosimeters were evaluated for in situ dose monitoring within the 0.5–8 Gy range during brachytherapy procedures using a 192Ir (392 keV) source. The results showed a clear linear relationship between the delivered radiation dose and the scintillation output measured by the fiber-optic detector. The Gd3Al2.5Ga2.5O12:Ce crystal detector exhibited excellent linearity, while the Al 2O3 :C and Al2O3:C,Mg crystal detectors also showed anearly linear dose–response relationship.  \nKeywords: fiber-optic detector; scintillation crystals; sapphire; garnets; brachytherapy;γ-rays  \n1. Introduction  \nRadiotherapy achieves its therapeutic objective by delivering the prescribed ionizing radiation dose with high spatial accuracy to the tumor volume, while minimizing exposure of surrounding healthy tissues, particularly organs at risk (OARs) . To meet this objective, robust quality assurance (QA) procedures must be applied to confirm that the treatment planning system (TPS) and treatment delivery system function accurately and remain within specified limits.  \nPatient-specific quality assurance (PS-QA) extends this verification process to the clinical environment, accounting for variables such as organ motion, anatomical changes, and applicator positioning uncertainties. These measurements can be performed prior to treatment or in situ, provided they do not perturb the intended dose deposition [1,2] . Robust PS-QA procedures are particularly critical in brachytherapy","cbCaiuUogykLyDJL","https://ap.wps.com/l/cbCaiuUogykLyDJL","pdf",1937535,14,"English","# Abstract\n# 1. Introduction","[{\"question\":\"What is the goal of this study on fiber-optic dosimeters in brachytherapy?\",\"answer\":\"To evaluate the applicability of fiber-optic dosimeters for in situ dose measurements during brachytherapy procedures using specific scintillation crystals and long optical fibers.\"},{\"question\":\"How was the radiation dose assessed in the experiments?\",\"answer\":\"Radiation dose delivery was determined by measuring the radioluminescence produced by the scintillation crystals, recorded through highly sensitive, compact luminescence spectrometers.\"},{\"question\":\"What radiation source and dose range were used for the in situ monitoring?\",\"answer\":\"A 192Ir source (392 keV) was used, and dosimeters were evaluated for in situ dose monitoring within the 0.5–8 Gy range.\"}]","In Situ Dose Measurements in Brachytherapy Using Scintillation Detectors Based on the Al2O3:C, Al2O3:C,Mg, and GAGG:Ce Crystals | PDF",1790770943,35,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/6948d2dd72f5a49253c97246d3c903e4.webp",983,1390,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/77e030cadb251ba357629a3a4d05f6fa.webp",982,1388,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/66d64041bf5add5916149044d3f85446.webp",981,1387,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/b22b6d140fa9ace18042465a3a7ef613.webp",980,1385]