[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-398108-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-398108-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","improved-viable-particle-discrimination-application-note-cc-129-rev-a-us","IMPROVED VIABLE PARTICLE DISCRIMINATION - Application Note CC-129 - Rev A (US)","","Application note CC-129 (Rev A, US) presents an improved viability determination algorithm for the TSI BioTrak Real-Time Viable Particle Counter. The update uses measured optical properties to discriminate viable particles and is compared against the previously validated high-sensitivity approach. The new algorithm is designed as a conservative improvement, keeping any particle deemed viable under the original method viable under the new one. Key focus includes improved detection performance for molds while preserving exclusion behavior for non-viable interferent particles.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/improved-viable-particle-discrimination-application-note-cc-129-rev-a-us/398108/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/improved-viable-particle-discrimination-application-note-cc-129-rev-a-us/398108.png","ImageObject",300,407,{"name":42,"@type":43},"lilac","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-28","2026-09-27",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",11,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What does the improved algorithm do for the BioTrak viable particle counter?","Question",{"text":63,"@type":64},"It determines particle viability using measured optical properties and updates viable discrimination while leaving total particle counts unchanged.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How does the new algorithm relate to the previously validated high-sensitivity algorithm?",{"text":68,"@type":64},"It is a conservative improvement: any particle classified as viable by the original high-sensitivity algorithm is also classified as viable by the new algorithm.",{"name":70,"@type":61,"acceptedAnswer":71},"Why were molds specifically targeted in developing the updated algorithm?",{"text":72,"@type":64},"Molds were not readily aerosolized during original algorithm development, so the original algorithm was not specifically trained for their optical signatures, motivating targeted improvements.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},398108,1790670268,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":97,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":112,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":118,"preview_page_count":33,"preview_urls":145},3985747861865,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","IMPROVED VIABLE  \nPARTICLE DISCRIMINATION  \nTSI BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER MODEL 9510  \nAPPLICATION NOTE CC-129 (9/16/2021) Rev A (US)  \nContents  \nIntroduction—Improved Viable Particle Discrimination for Pharma ............................................... 1  \nBackground—Evolving Particle Detection Algorithms ........................................................................... 2  \nScope—Changes Associated with Updating the Algorithm .................................................................... 2  \nMethods—Comparing Algorithms................................................................................................................... 3  \nResults—Proof is in the Data............................................................................................................................. 4  \nMicroorganisms.......................................................................................................................................................... 4  \nNon-Viable Particles (i.e., interferents) ............................................................................................................ 6  \nZero-Counting ............................................................................................................................................................. 7  \nSummary & Conclusions—TSI Delivers Trusted Detection ................................................................... 8  \nIntroduction—Improved Viable Particle Discrimination for Pharma  \nThis application note describes the performance of a new algorithm developed for use by the BioTrak® Real-Time Viable Particle Counter to determine the viability of a particle based on its measured optical properties. The new algorithm will be compared relative to the previously validated highsensitivity algorithm—specifically describing the impact of the new algorithm on viable particle discrimination with respect to test aerosols of microorganisms and interferents (non-viable particulates) .  \nThe new algorithm is a conservative improvement to the previously validated version. This means that any particle that was considered viable by the original high-sensitivity algorithm is also considered viable by the new algorithm.  \nThe new algorithm was developed chiefly to improve the detection capability of molds. Molds were not readily aerosolized during the development of the original algorithm and, therefore, it was not specifically trained to detect those optical signatures. Improvements made in the detection of molds are clearly demonstrated in the results section.  \nBackground—Evolving Particle Detection Algorithms  \nDuring initial product development of the BioTrak Real-Time Viable Particle Counter, two viable particle detection algorithms, labeled as high-sensitivity and normal, were created. The normal sensitivity algorithm was developed with the intent to balance false positive and false negative counts to produce an accurate estimate in samples with relatively high counts. The high-sensitivity algorithm was more conservative in that it prioritized the decreasing likelihood of false negative counts at the risk of slightly increasing the likelihood of false positive counts. Given the desire to optimize the detection of as many viable particles as possible in Grade A areas, the pharmaceutical industry most widely adopted the use of the high-sensitivity setting. For this reason, the high-sensitivity algorithm was utilized for validation testing conducted in 2013.  \nThe algorithms were empirically derived from the data generated by the optical sensors in the viability chamber of the instrument while sampling aerosolized microorganisms and interferents. Aerosolization of microorganisms during testing was achieved using an Ink Jet Aerosol Generator (IJAG). Some microorganisms proved to be sensitive to this method and retained little to no viability upon dissemination. Limited data was available for algorithm development a","cbCailFKYlZCWkqw","https://ap.wps.com/l/cbCailFKYlZCWkqw","pdf",660971,"English","# Introduction—Improved Viable Particle Discrimination for Pharma\n# Background—Evolving Particle Detection Algorithms\n# Scope—Changes Associated with Updating the Algorithm\n# Methods—Comparing Algorithms\n# Results—Proof is in the Data\n## Microorganisms\n## Non-Viable Particles (i.e., interferents)\n## Zero-Counting\n# Summary & Conclusions—TSI Delivers Trusted Detection","[{\"question\":\"What does the improved algorithm do for the BioTrak viable particle counter?\",\"answer\":\"It determines particle viability using measured optical properties and updates viable discrimination while leaving total particle counts unchanged.\"},{\"question\":\"How does the new algorithm relate to the previously validated high-sensitivity algorithm?\",\"answer\":\"It is a conservative improvement: any particle classified as viable by the original high-sensitivity algorithm is also classified as viable by the new algorithm.\"},{\"question\":\"Why were molds specifically targeted in developing the updated algorithm?\",\"answer\":\"Molds were not readily aerosolized during original algorithm development, so the original algorithm was not specifically trained for their optical signatures, motivating targeted improvements.\"}]","IMPROVED VIABLE PARTICLE DISCRIMINATION - Application Note CC-129 - Rev A (US) | PDF",1790471317,[146,150,154,158],{"page_no":22,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/a22c10aa7996fec1bd3292c1221314c7.webp",983,1272,{"page_no":26,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/f4010037e544b61d7121e86bccd481fb.webp",982,1270,{"page_no":30,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/287e59fca937f88cebf6c18752164e26.webp",981,1269,{"page_no":33,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/3f27dcac809ab43982289036806b848b.webp",980,1268]