[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-detail-665494-en":59,"doc-seo-665494-105":81},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":5,"data":60},{"doc_id":61,"user_id":62,"nickname":63,"user_avatar":64,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":66,"doc_content":67,"file_id":68,"file_url":69,"file_type":70,"file_size":71,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":72,"language":73,"language_code":74,"site_id":75,"html_lang":74,"table_of_contents":76,"faqs":77,"seo_title":78,"seo_description":66,"update_tm":79,"read_time":80},665494,7971474921005,"Grenda","https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","IEEE CED GTG Single Line Diagram Examples - Technical Reference Guide","This document provides a comprehensive technical reference for various single-line diagram (SLD) configurations used in industrial and electrical power systems. It covers a wide range of architectures including overall plant diagrams, cogeneration (cogen) plants, offshore installations, independent power producer (IPP) configurations, and islanded systems with gas turbine generators (GTG). Each example illustrates essential electrical infrastructure components such as generator circuit breakers (GCB), feeders (FB), and energy storage systems (ESS) across multiple voltage levels including 138kV, 13.8kV, 4.16kV, and 480V. By presenting diverse operational scenarios—from islanded bus connections to diesel exercise routines—this collection serves as a standard guide for electrical engineers and power system designers to analyze, reference, and implement effective single-line electrical layouts for complex power generation and distribution projects.","138kV-13.8kV  \n138kV-13.8kV  \nGCB  \n1  \nFB1  \nFB2  \nFB3  \n13.8kV  \nGCB  \n1  \n1  \nMW  \n13.8kV-4. 16kV  \n4. 16kV  \n480V  \n150kW  \n13.8kV-480V  \nEXAMPLE OVERALL PLANT SINGLE LINE DIAGRAM  \n138kV-13.8kV  \n138kV-13.8kV  \n\n|  |  |  | 13.8kV |\n| --- | --- | --- | --- |\n|  |  |  |  |\n\nGCB  \n1  \nFB1  \n480V  \nFB2  \nFB3  \n13.8kV-4. 16kV 13.8kV-480V  \n4. 16kV  \nGCB  \n1  \nGCB  \n1  \n5MW  \n1MW  \n150kW  \nEXAMPLE PLANT COGEN  \nGCB  \n1  \nFB1  \nGCB  \n2  \nGCB  \n3  \nFB2  \nGCB  \n4  \n4. 16kV  \n4. 16kV-480kV  \n4. 16kV  \nEXAMPLE OFFSHORE SINGLE LINE DIAGRAM  \n13.8kV-138kV  \nIPP1 100MW  \n13.8kV-138kV  \n\n| GCB\u003Cbr>1 |  |\n| --- | --- |\n|  |  |\n| U1 |  |\n\n| GCB\u003Cbr>2 |  |\n| --- | --- |\n|  |  |\n| U2 |  |\n\n138kV  \nEXAMPLE IPP  \n13.8kV-138kV  \nG1  \n40MW  \n13.8kV-138kV  \n13.8kV-138kV  \nG3  \n40MW  \n13.8kV-138kV  \n\n| GCB\u003Cbr>1 |  |\n| --- | --- |\n|  |  |\n| F1 |  |\n\n| GCB\u003Cbr>2 |  |\n| --- | --- |\n|  |  |\n| F2 |  |\n\n138kV  \nEXAMPLE ISLAND 138KV  \nG1  \n10MW  \n\n|  | 4. 16kV |\n| --- | --- |\n|  |  |\n\nFB1  \nGCB  \n1  \nLOAD  \nEXAMPLE ISLAND BUS CONNECTED / 1 GTG  \n|  |  | 4. 16kV |\n| --- | --- | --- |\n|  |  |  |\n\nFB1  \nGCB  \n1  \nGCB  \n2  \nLOAD  \nEXAMPLE ISLAND BUS CONNECTED / 2 GTG  \n| 13.8kV |  |  |  |  |\n| --- | --- | --- | --- | --- |\n|  |  |  |  |  |\n\nGCB  \n1  \nFB1  \nGCB  \n2  \nGCB  \n3  \nFB2  \nESS  \n1MW  \n13.8kV-480kV  \nGCB  \n4  \n\n| INC1 |  |\n| --- | --- |\n|  |  |\n| FB\u003Cbr>A |  |\n\n480V  \nEXAMPLE WEEKLY DIESEL EXCERCISE","cbCairb1zDF2U6P7","https://ap.wps.com/l/cbCairb1zDF2U6P7","pdf",103384,14,"English","en",105,"# Overall Plant and Cogen Configurations\n## Plant Single Line Diagram\n## Cogen Plant Layout\n# Specialized Power Systems\n## Offshore Single Line Diagram\n## IPP and Islanded Configurations\n# Operational Examples\n## Island Bus Connected Diagrams\n## Weekly Diesel Exercise Layout","[{\"question\":\"What common voltage levels are featured in these single-line diagrams?\",\"answer\":\"The document highlights various voltage levels including 138kV, 13.8kV, 4.16kV, and 480V, representing different stages of power generation and distribution.\"},{\"question\":\"What types of power systems are represented in the examples?\",\"answer\":\"The examples cover a broad range of systems including overall plant diagrams, cogeneration plants, offshore platforms, independent power producers (IPP), and islanded generator setups.\"},{\"question\":\"What key electrical components are indicated in the diagrams?\",\"answer\":\"Key components include Generator Circuit Breakers (GCB), various Feeders (FB), Energy Storage Systems (ESS), and specific power sources like gas turbines and diesel generators.\"}]","IEEE CED GTG Single Line Diagram Examples - Technical Reference Guide | PDF",1793304502,35,{"code":4,"msg":82,"data":83},"ok",{"site_id":75,"language":74,"slug":84,"title":65,"keywords":85,"description":66,"schema_data":86,"social_meta":140,"head_meta":142,"extra_data":144,"updated_unix":79},"ieee-ced-gtg-single-line-diagram-examples-technical-reference-guide","",{"@graph":87,"@context":139},[88,102,122],{"@type":89,"itemListElement":90},"BreadcrumbList",[91,95,97,100],{"item":92,"name":93,"@type":94,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":96,"name":9,"@type":94,"position":14},"https://docshare.wps.com/document/",{"item":98,"name":30,"@type":94,"position":99},"https://docshare.wps.com/document/technology/",3,{"item":101,"name":65,"@type":94,"position":19},"https://docshare.wps.com/document/ieee-ced-gtg-single-line-diagram-examples-technical-reference-guide/665494/",{"url":101,"name":65,"@type":103,"image":104,"author":109,"headline":65,"publisher":111,"fileFormat":114,"inLanguage":74,"description":66,"dateModified":115,"datePublished":116,"encodingFormat":114,"isAccessibleForFree":117,"interactionStatistic":118},"DigitalDocument",{"url":105,"@type":106,"width":107,"height":108},"https://docshare.wps.com/thumbnails/ieee-ced-gtg-single-line-diagram-examples-technical-reference-guide/665494.png","ImageObject",300,407,{"name":63,"@type":110},"Person",{"url":92,"name":112,"@type":113},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":119,"interactionType":120,"userInteractionCount":24},"InteractionCounter",{"@type":121},"ViewAction",{"@type":123,"mainEntity":124},"FAQPage",[125,131,135],{"name":126,"@type":127,"acceptedAnswer":128},"What common voltage levels are featured in these single-line diagrams?","Question",{"text":129,"@type":130},"The document highlights various voltage levels including 138kV, 13.8kV, 4.16kV, and 480V, representing different stages of power generation and distribution.","Answer",{"name":132,"@type":127,"acceptedAnswer":133},"What types of power systems are represented in the examples?",{"text":134,"@type":130},"The examples cover a broad range of systems including overall plant diagrams, cogeneration plants, offshore platforms, independent power producers (IPP), and islanded generator setups.",{"name":136,"@type":127,"acceptedAnswer":137},"What key electrical components are indicated in the diagrams?",{"text":138,"@type":130},"Key components include Generator Circuit Breakers (GCB), various Feeders (FB), Energy Storage Systems (ESS), and specific power sources like gas turbines and diesel generators.","https://schema.org",{"og:url":101,"og:type":141,"og:title":65,"og:site_name":112,"og:description":66},"article",{"robots":143,"canonical":101},"index,follow",{"doc_id":61,"site_id":75}]