[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-514284-105":59,"doc-detail-514284-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","iecex-eps-130045u-issue-3-certificate-of-conformity","IECEx EPS 13.0045U - Issue 3 - Certificate of Conformity","","IECEx EPS 13.0045U is an IECEx certificate of conformity for an Ex component used in explosive atmospheres. It specifies the applicant BARTEC GmbH and the manufacturer and production locations, and identifies the component as a line bushing type 07-91**-*****and 57-91*****. The document records the issue date and status, lists applicable standards IEC 60079-0 and IEC 60079-1, and references test and quality assessment reports. It also includes schedules of limitations and special installation conditions for use in flameproof enclosures.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/iecex-eps-130045u-issue-3-certificate-of-conformity/514284/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/iecex-eps-130045u-issue-3-certificate-of-conformity/514284.png","ImageObject",300,407,{"name":92,"@type":93},"Blitz","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-19","2026-10-06",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What is the certificate number and issue information for IECEx EPS 13.0045U?","Question",{"text":113,"@type":114},"The certificate number is IECEx EPS 13.0045U, issued on 2023-03-27. The document indicates Issue No: 3 and includes an issue history with earlier issues listed.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"Which Ex component is covered by this certificate?",{"text":118,"@type":114},"The certificate covers an Ex component identified as a line bushing, specifically type 07-91**-*****and 57-91***** (with related type usage described in the schedule).",{"name":120,"@type":111,"acceptedAnswer":121},"Which standards and test/assessment reports are referenced?",{"text":122,"@type":114},"The certificate references IEC 60079-0:2017 (general requirements) and IEC 60079-1:2014-06 (flameproof enclosures, “d”). It also cites a test report DE/EPS/ExTR13.0032/03 and quality assessment reports such as IT/CES/QAR12.0006/09 and DE/TUN/QAR06.0017/14.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},514284,1791565014,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":24,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},24464137899374,"https://us-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","| IECEx Certificate  \u003Cbr>IECEx  \u003Cbr>of Conformity  \u003Cbr>INTERNATIONAL ELECTROTECHNICAL COMMISSION  \u003Cbr>IEC Certification System for Explosive Atmospheres  \u003Cbr>for rules and details of the IECEx Scheme visit www.iecex.com  \u003Cbr>Ex COMPONENT CERTIFICATE  \u003Cbr>Certificate history:  \u003Cbr>Certificate No.:  \u003Cbr>ECEx EPS 13.0045U  \u003Cbr>Page 1 of 4  \u003Cbr>Issue 2(2018-11-30)  \u003Cbr>Status:  \u003Cbr>Issue No:3  \u003Cbr>Current  \u003Cbr>ssue 1 (2017-10-24)  \u003Cbr>ssue 0(2014-02-07)  \u003Cbr>Date of lssue:  \u003Cbr>2023-03-27  \u003Cbr>Applicant:  \u003Cbr>BARTEC GmbH  \u003Cbr>Max-Eyth-Straße 16  \u003Cbr>97980 Bad Mergentheim  \u003Cbr>Germany  \u003Cbr>Ex Component:  \u003Cbr>Line bushing 07-91**-*****and 57-91*****  \u003Cbr>This component is NOT intended to be used alone and requires adiona consideration when incorporated into other equipment or systems  \u003Cbr>for use in explosive atmospheres (refer to IEC 60079-0)  \u003Cbr>Type of Protection:  \u003Cbr>db  \u003Cbr>Marking:  \u003Cbr>Ex db IIC Gb  \u003Cbr>Ex db I Mb  \u003Cbr>Ulrich Felke  \u003Cbr>Approved for issue on behalf of the IECEx  \u003Cbr>Certification Body:  \u003Cbr>Head of Certification  \u003Cbr>Position:  \u003Cbr>Signature:  \u003Cbr>(for printed version)  \u003Cbr>Date:  \u003Cbr>2023-03-27  \u003Cbr>(for printed version)  \u003Cbr>1.This certificate and schedule may only be reproduced in full.  \u003Cbr>2.This certificate is not transferable and remains the property of the issuing body.  \u003Cbr>3.The Status and authenticity of this certificate may be verified by visiting www.iecex.com or use of this QR Code.  \u003Cbr>Certificate issued by:  \u003Cbr>Bureau Veritas Consumer Products Services Germany GmbH  \u003Cbr>Businesspark A96  \u003Cbr>86842 Türkheim  \u003Cbr>BUREAU  \u003Cbr>Germany   |\n| --- |\n\n| IECEx Certificate  \u003Cbr>IECEx  \u003Cbr>of Conformity  \u003Cbr>IECEx EPS 13.0045U  \u003Cbr>Certificate No.:  \u003Cbr>Page 2 of 4  \u003Cbr>2023-03-27  \u003Cbr>Date of issue:  \u003Cbr>Issue No:3  \u003Cbr>Manufacturer:  \u003Cbr>BARTEC GmbH  \u003Cbr>Max-Eyth-Straße 16  \u003Cbr>97980 Bad Mergentheim  \u003Cbr>Germany  \u003Cbr>FENEX S.r.I.  \u003Cbr>BARTEC GmbH  \u003Cbr>Manufacturing  \u003Cbr>Max-Eyth-Straße 16  \u003Cbr>locations:  \u003Cbr>Via Carducci 16  \u003Cbr>34070 Moraro(GO)  \u003Cbr>97980 Bad Mergentheim  \u003Cbr>Germany  \u003Cbr>Italy  \u003Cbr>This certificate is issued as verification that a sample(s).representative of production.was assessed and tested and found to comply with the  \u003Cbr>IEC Standard list below and that the manufacturer's quality system,relating to the Ex products coveredby this certificate,was assessed and  \u003Cbr>found to comply with the IECEx Quality system requirements.This certificate is granted subject to the conditions as set out in IECEx Scheme  \u003Cbr>Rules,IECEx02 and Operational Documents as amended  \u003Cbr>STANDARDS:  \u003Cbr>The component and any acceptable variations to it specified in the schedule of this certificate and the identified documents,was found  \u003Cbr>to comply with the following standards  \u003Cbr>IEC 60079-0:2017 Explosive atmospheres-Part 0:Equipment -General requirements  \u003Cbr>Edition:7.0  \u003Cbr>IEC 60079-1:2014-06 Explosive atmospheres-Part 1:Equipment protection by flameproof enclosures \"d\"  \u003Cbr>Edition:7.0  \u003Cbr>This Certificate does not indicate compliance with safetv and performance requirements  \u003Cbr>other than those expressly included in the Standards listed above.  \u003Cbr>TEST &ASSESSMENT REPORTS:  \u003Cbr>A sample(s)of the component listed has successflly met the examination and test requirementsa ecorded in  \u003Cbr>Test Report:  \u003Cbr>DE/EPS/ExTR13.0032/03  \u003Cbr>Quality Assessment Reports:  \u003Cbr>IT/CES/QAR12.0006/09  \u003Cbr>DE/TUN/QAR06.0017/14   |\n| --- |\n\nCertificate No.:  \nIECEx EPS 13.0045U  \nDate of issue:  \n2023-03-27  \nEx Component(s)covered by this certificate is described below:  \nFor details see additional sheet in annex to CoC.  \nSCHEDULE OF LIMITATIONS:  \nThe max.arm length of a connection fixture of type 07-91*9-****S***is limited to 100 mm.  \nIECEx Certificateof Conformity  \nPage 3 of 4  \nIssue No:3  \nThe line bushing type 07-91*******and 57-91*****are used for the electrical connection of electrical equipment in explosion-proofenclosures.This may be the connection between a flame-proof housing and housing in a","cbCaijGRhzUr0orF","https://ap.wps.com/l/cbCaijGRhzUr0orF","pdf",1779648,"English","# IECEx of Conformity\n## Certificate details\n## Standards, testing, and limitations\n## Schedule of limitations and conditions","[{\"question\":\"What is the certificate number and issue information for IECEx EPS 13.0045U?\",\"answer\":\"The certificate number is IECEx EPS 13.0045U, issued on 2023-03-27. The document indicates Issue No: 3 and includes an issue history with earlier issues listed.\"},{\"question\":\"Which Ex component is covered by this certificate?\",\"answer\":\"The certificate covers an Ex component identified as a line bushing, specifically type 07-91**-*****and 57-91***** (with related type usage described in the schedule).\"},{\"question\":\"Which standards and test/assessment reports are referenced?\",\"answer\":\"The certificate references IEC 60079-0:2017 (general requirements) and IEC 60079-1:2014-06 (flameproof enclosures, “d”). It also cites a test report DE/EPS/ExTR13.0032/03 and quality assessment reports such as IT/CES/QAR12.0006/09 and DE/TUN/QAR06.0017/14.\"}]","IECEx EPS 13.0045U - Issue 3 - Certificate of Conformity | PDF",1791298242,13,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/75737d64f25adad456d6b099e3bd450e.webp",983,1383,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/bac5dae0c6e7d47d03e2848e9a61aee1.webp",982,1380,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/5f35668e31ed4c0b852106046c860c45.webp",981,1375,{"page_no":19,"url":160,"width":161,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/9898b8802330a3d796cf0356fe6596f4.webp",980]