[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-674564-105":59,"doc-detail-674564-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","icp-force-sensor-operation-manual-model-208c02","ICP Force Sensor Operation Manual - Model 208C02","","Installation and operating guidance for PCB Piezotronics ICP force sensor Model 208C02, including how the built-in MOSFET amplifier converts high-impedance charge output into a low-impedance voltage signal. Explains power requirements using a 24–27 VDC, 2–20 mA constant current supply, benefits versus charge-mode sensors, and suitability for continuous monitoring over long coaxial or ribbon cables. Also describes series-level applications and mounting considerations referenced for the purchased sensor model.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/icp-force-sensor-operation-manual-model-208c02/674564/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/icp-force-sensor-operation-manual-model-208c02/674564.png","ImageObject",300,407,{"name":92,"@type":93},"WPS_1793603815","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04",true,{"@type":101,"interactionType":102,"userInteractionCount":4},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What does an ICP force sensor’s built-in MOSFET amplifier do?","Question",{"text":111,"@type":112},"It converts the sensor’s high-impedance charge output into a low-impedance voltage signal suitable for analysis or recording.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What power supply type is generally used to operate ICP force sensors?",{"text":116,"@type":112},"ICP sensors are powered by a low cost, 24–27 VDC, 2–20 mA constant current supply.",{"name":118,"@type":109,"acceptedAnswer":119},"How do compression and tensile inputs affect the output signal?",{"text":120,"@type":112},"Compression forces directed against the sensing surface produce a positive-going output, while tensile output relates to static steady-state loading and removal; charge mode polarity behavior differs unless polarity reversal is specified.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},674564,1793764556,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":4,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":138,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":128,"read_time":36},12232076219891,"https://eur-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","Model 208C02  \nPlatinum Stock Products; Multi-purpose, ICP® force sensor, 100 lb comp., 100 lb tension, 50  \nmV/lb  \nInstallation and Operating Manual  \nFor assistance with the operation of this product,  \ncontact the PCB Piezotronics, Inc.  \nToll-free: 716-684-0001  \n24-hour SensorLine: 716-684-0001  \nFax: 716-684-0987  \nE-mail: [info@pcb.com](info@pcb.com)  \n[Web: www.pcb.com](Web: www.pcb.com)  \n| ICP􀀁 FORCE SENSOR OPERATION MANUAL |  |  |\n| --- | --- | --- |\n|  | 1 |  |\n|  |  |  |\n\n1.0 INTRODUCTION  \nICP􀀁 force sensors incorporate a built-in MOSFET microelectronic amplifier. This serves to convert the high impedance charge output into a low impedance voltage signal for analysis or recording. ICP􀀁 sensors, are powered from a separate constant current source, operate over long ordinary coaxial or ribbon cable without signal degradation. The low impedance voltage signal is not affected by triboelectric cable noise or environmental contaminants.  \nFigure 1-ICP􀀁 Sensor System Schematic  \nPower to operate ICP􀀁 sensors is generally in the form of a low cost, 24-27 VDC, 2-20 mA constant current supply. Figure 1 schematically illustrates a typical ICP􀀁 sensor system. PCB offers a number of AC or battery-powered, single or multichannel power/signal conditioners, with or without gain capabilities for use with force sensors. In addition, many data acquisition systems now incorporate constant current power for directly powering ICP􀀁 sensors. Because static calibration or quasi-static short-term response lasting up to a few seconds is often required, PCB manufactures signal conditioners that provide DC coupling. Figure 2 summarizes a complete 2-wire ICP􀀁 system configuration.  \nFigure 2 Typical ICP􀀁 Sensor System  \nIn addition to ease of operation, ICP􀀁 force sensors offer significant advantages over charge mode types. Because of the low impedance output and solid-state, hermetic construction, ICP􀀁 force sensors are well suited for continuous, unattended force monitoring in harsh factory environments. Also, ICP􀀁 sensor cost-per-channel is substantially lower, since they  \noperate through standard, low-cost coaxial cable, and do not require expensive charge amplifiers.  \nRefer to the installation/outline drawing and specification sheet at the back of this manual for details and dimensions of the particular sensor model number(s) purchased. The following pages give a brief description of the various sensor series available, recommended mounting procedures, operation and recommended calibration.  \nIn addition to PCB’s line of ICP® sensors, each ICP® sensor series outlined has corresponding charge output versions. Charge mode versions with high output impedance are suited for higher temperature, metal-to-metal and very high shock applications. These models can also be used for applications where it is desirable to manually set the output range.  \nIn addition to standard products, PCB has the ability to design and manufacture custom sensors/systems for specific applications.  \nIf questions arise regarding the operation or characteristics of the force sensor products as outlined in this manual, feel free to contact an experienced PCB applications engineer toll-free at 1-800-828-8840.  \n2.0 DESCRIPTION  \nIMPACT  \nSeries 200 Impact Sensors are designed to measure compression and impact forces from a fraction of a lb (N) to 50,000 lb (to 22.4 kN) . The flat sensing surface located on the top of the sensor is designed to measure a dynamic force quickly applied axially to the sensor.  \nAs highlighted in Figure 3 compression forces directed against the sensing surface produce a positive-going output. A tensile output could be obtained if a static, steady-state load were applied to the sensor. The maximum tensile output to be measured would be that of the applied static, steady state load as that load is quickly removed.  \nThis force-directed input and corresponding output will provide a positive going output signal in ICP􀀁 models and a negative goi","cbCairgTRTfuCcj2","https://ap.wps.com/l/cbCairgTRTfuCcj2","pdf",1947375,16,"English","# 1.0 Introduction\n## ICP force sensor signal conversion and power\n## Advantages and applications overview\n# 2.0 Description\n## Impact series (Series 200)\n## Compression vs tensile output polarity\n## Rings series (Series 201B to 207C)","[{\"question\":\"What does an ICP force sensor’s built-in MOSFET amplifier do?\",\"answer\":\"It converts the sensor’s high-impedance charge output into a low-impedance voltage signal suitable for analysis or recording.\"},{\"question\":\"What power supply type is generally used to operate ICP force sensors?\",\"answer\":\"ICP sensors are powered by a low cost, 24–27 VDC, 2–20 mA constant current supply.\"},{\"question\":\"How do compression and tensile inputs affect the output signal?\",\"answer\":\"Compression forces directed against the sensing surface produce a positive-going output, while tensile output relates to static steady-state loading and removal; charge mode polarity behavior differs unless polarity reversal is specified.\"}]","ICP Force Sensor Operation Manual - Model 208C02 | PDF"]