[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-641020-105":59,"doc-detail-641020-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","ici-caldaie-gx-installation-use-and-maintenance-manual-three-pass-steam-boiler","Ici Caldaie GX - Installation, Use and Maintenance Manual - Three-pass Steam Boiler","","Installation, use and maintenance manual for the three-pass GX steam boiler series. Provides guidance on compliance with relevant European directives, safety warnings, forbidden actions, hazard identification, and appliance identification and description including structure and dimensions. Covers installation steps such as receipt, handling, cleaning, hydraulic and flue exhaust connections, burner assembly, and electrical connections. Includes commissioning, mandatory periodic verifications, routine and extraordinary maintenance, anomaly remedies, environmental protection, decommissioning, and risk analysis, plus useful declarations like QR code references.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/ici-caldaie-gx-installation-use-and-maintenance-manual-three-pass-steam-boiler/641020/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/ici-caldaie-gx-installation-use-and-maintenance-manual-three-pass-steam-boiler/641020.png","ImageObject",300,407,{"name":92,"@type":93},"OKfine","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-27","2026-10-22",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the GX steam boiler manual intended to cover?","Question",{"text":112,"@type":113},"It covers installation, commissioning, use, and maintenance of the GX three-pass steam boilers, including required checks and safety guidance.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which directives are the GX steam generators compliant with?",{"text":117,"@type":113},"The manual states compliance with Directive 2014/68/EU (PED), Low Voltage Directive 2014/35/EU, and Electromagnetic Compatibility Directive 2014/30/EU.",{"name":119,"@type":110,"acceptedAnswer":120},"What should be done if the generator supply is damaged or does not match the order?",{"text":121,"@type":113},"Upon receipt, ensure the supply is intact; if it does not correspond to the order or is damaged, promptly contact ICI CALDAIE S.p.A. for assistance.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},641020,1793030206,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},962093957596,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","EN  \nThree-pass steam boiler  \nGX  \nINSTALLATION, USE AND MAINTENANCE MANUAL  \nGX_ 1000_ 15000_en_00-06/2019  \nINDEX  \nGeneral information  \n3 Introduction  \n3 Range  \n3 Compliance  \n4 Warnings  \n5 Prohibitions  \n5 Hazards  \n6 Identification  \n7 Appliance description  \n7 Structure  \n8 Dimensions and connections  \n10 Technical data  \n11 Burners  \n12 Paperwork  \n12 Fire prevention  \n13 Components  \nInstallation  \n18 Product receipt  \n19 Handling  \n19 Film removal  \n20 Installation room  \n21 System cleaning  \n21 Hydraulic connections  \n21 Starting hydraulic circuit  \n22 Flue exhaust  \n22 Front door opening  \n23 Burner assembly  \n23 Accessing the burner nosepiece  \n24 Electrical connections  \n25 Loading and supply of the generator/system  \nUse  \n28 Preliminary checks  \n28 Thermal expansion  \n29 Commissioning  \n30 Checks after commissioning  \n30 Mandatory periodic verifications  \n30 Stop periods  \nMaintenance  \n31 Periodic verifications  \n32 Methods for checking the safety devices  \n33 Routine maintenance  \n33 Extraordinary maintenance  \n34 Any anomalies and remedies  \n34 Protecting the environment  \n34 Decommissioning and disposal  \nRisk analysis  \nUseful information and declarations  \n39 QR code  \nNotes  \nSYMBOLS USED IN THE MANUAL  \na DANGER  \nTo indicate actions that, if not performed correctly, can result in injury of generic origin or may generate malfunction or damage to the appliance; therefore require particular caution and adequate preparation.  \n\n| d | IT IS FORBIDDEN\u003Cbr>To indicate operations that SHOULD NOT be performed. |\n| --- | --- |\n\n\n| m | IMPORTANT\u003Cbr>To indicate particularly useful information and important. |\n| --- | --- |\n\nThe illustrations and data presented are not binding. The company reserves the right to make without prior notice any changes it deems appropriate for continuous improvement and constant updating.  \n2  \n1 General information  \nINTRODUCTION  \nDear Customer,  \nThank you for having chosen an appliance of the series GX, a high quality and efficiency product, reliable and safe.  \nWe recommend entrusting its maintenance to Professionally Qualified Personnel who, when necessary, uses original spare parts. This manual contains important information and suggestions that must be observed for easier installation and best possible use of the appliance.  \n\n| m | IMPORTANT\u003Cbr>Failure to observe the instructions in this manual will void the warranty conditions. |\n| --- | --- |\n\nm IMPORTANT  \nThis manual refers to boilers with “standard accessories”.  \nFor boilers that“do not require continuous monitoring” by the operator refer to the specific technical manual.  \nRANGE  \n\n| MODEL | CODE | MODEL | CODE | MODEL | CODE | MODEL | CODE | MODEL | CODE |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| GX 12 bar |  |  |  |  |  |  |  |  |  |\n| GX 1000 | 86161000 | GX 2000 | 86162000 | GX 4000 | 86164000 | GX 8000 | 86168000 | GX 13000 | 86169913 |\n| GX 1200 | 86161200 | GX 2500 | 86162500 | GX 5000 | 86165000 | GX 9000 | 86169000 | GX 15000 | 86169915 |\n| GX 1500 | 86161500 | GX 3000 | 86163000 | GX 6000 | 86166000 | GX 10000 | 86169900 |  |  |\n| GX 1750 | 86161750 | GX 3500 | 86163500 | GX 7000 | 86167000 | GX 12000 | 86169912 |  |  |\n| GX 12 bar EXP |  |  |  |  |  |  |  |  |  |\n| GX 1000 | 86161004 | GX 2000 | 86162004 | GX 4000 | 86164004 | GX 8000 | 86168004 | GX 13000 | 86169923 |\n| GX 1200 | 86161204 | GX 2500 | 86162504 | GX 5000 | 86165004 | GX 9000 | 86169004 | GX 15000 | 86169925 |\n| GX 1500 | 86161504 | GX 3000 | 86163004 | GX 6000 | 86166004 | GX 10000 | 86169904 |  |  |\n| GX 1750 | 86161754 | GX 3500 | 86163504 | GX 7000 | 86167004 | GX 12000 | 86169922 |  |  |\n| GX 15 bar |  |  |  |  |  |  |  |  |  |\n| GX 1000 | 86171000 | GX 2000 | 86172000 | GX 4000 | 86174000 | GX 8000 | 86178000 | GX 13000 | 86179913 |\n| GX 1200 | 86171200 | GX 2500 | 86172500 | GX 5000 | 86175000 | GX 9000 | 86179000 | GX 15000 | 86179915 |\n| GX 1500 | 86171500 | GX 3000 | 86173000 | GX 6000 | 86176000 | GX 10000 |","cbCaiuBoxApZAedP","https://ap.wps.com/l/cbCaiuBoxApZAedP","pdf",4059074,44,"English","# Introduction\n## Range\n## Compliance\n## Warnings\n## Prohibitions and Hazards\n## Identification and Appliance Description\n# Installation\n## Product receipt and Handling\n## Installation room and System cleaning\n## Hydraulic and Flue exhaust connections\n## Burner assembly and Electrical connections\n# Use and Maintenance\n## Preliminary checks and Commissioning\n## Checks after commissioning and Mandatory periodic verifications\n## Stop periods\n## Periodic and Routine maintenance\n## Extraordinary maintenance and Anomalies\n## Protecting the environment\n## Decommissioning and disposal\n# Risk analysis\n# Useful information and declarations\n## QR code\n# Notes","[{\"question\":\"What is the GX steam boiler manual intended to cover?\",\"answer\":\"It covers installation, commissioning, use, and maintenance of the GX three-pass steam boilers, including required checks and safety guidance.\"},{\"question\":\"Which directives are the GX steam generators compliant with?\",\"answer\":\"The manual states compliance with Directive 2014/68/EU (PED), Low Voltage Directive 2014/35/EU, and Electromagnetic Compatibility Directive 2014/30/EU.\"},{\"question\":\"What should be done if the generator supply is damaged or does not match the order?\",\"answer\":\"Upon receipt, ensure the supply is intact; if it does not correspond to the order or is damaged, promptly contact ICI CALDAIE S.p.A. for assistance.\"}]","Ici Caldaie GX - Installation, Use and Maintenance Manual - Three-pass Steam Boiler | PDF",1792712488,111]