[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663464-105":59,"doc-detail-663464-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","hydraulic-elevators-appendix-14-a-hydraulic-elevator-installation-safety-requirements","Hydraulic Elevators - Appendix 14-A - Hydraulic Elevator Installation & Safety Requirements","","Specification for hydraulic passenger elevator work covering elevator cars, hoistway entrances, jacks, and operation/control systems, including accessibility provisions and required equipment, controls, pit ladders, and operating devices. Includes requirements for submittals such as product data, shop drawings, color selections, certificates, and operation and maintenance documentation. Defines manufacturer and installer qualifications, regulatory compliance (ASME A17.1, IBC, NFPA 70/80, Texas Accessibility Standards), fire-rated entrance assemblies, inspection/testing, delivery and handling, project painting, and 12-month warranty and maintenance call-back service.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/hydraulic-elevators-appendix-14-a-hydraulic-elevator-installation-safety-requirements/663464/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/hydraulic-elevators-appendix-14-a-hydraulic-elevator-installation-safety-requirements/663464.png","ImageObject",300,407,{"name":92,"@type":93},"GGG","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What elevator components and systems are included in the hydraulic elevator scope?","Question",{"text":112,"@type":113},"The scope includes hydraulic passenger elevators and passenger work, elevator car enclosures, hoistway entrances, signal equipment, jacks, operation and control systems, accessibility provisions, and all equipment and devices needed for safe rated operation.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What submittals are required before installation?",{"text":117,"@type":113},"When requested, product data for car enclosures and hoistway entrances must be submitted, along with shop drawings showing equipment arrangement and capacities, performances, safety features, finishes, floor coverage, travel distances, and electrical power requirements. Color charts, samples, certificates, and operation and maintenance data are also required.",{"name":119,"@type":110,"acceptedAnswer":120},"Which standards and regulatory requirements govern safety and fire-related elements?",{"text":121,"@type":113},"The specification requires compliance with ASME A17.1, International Building Code, NFPA 70, NFPA 80, Texas Accessibility Standards, and Texas Department of Licensing and Regulation requirements. Fire-rated entrance assemblies must comply with ASTM E152, UL 10B, and NFPA 80, with UL Class B labels or equivalent.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663464,1793228309,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},962093532725,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","HYDRAULIC ELEVATORS  \nGeneral  \nSummary  \nSection includes: Hydraulic passenger elevator as shown and specified. Elevator work includes:  \n1. Commercial, hydraulic elevators; passenger.  \n2. Elevator car enclosures, hoistway entrances and signal equipment.  \n3. Jacks.  \n4. Operation and control systems.  \n5. Accessibility provisions for physically disabled persons.  \n6. Equipment, machines, controls, pit ladders, systems and devices as required for safely operating the specified elevators at their rated speed and capacity.  \n7. Materials and accessories as required to complete the elevator installation.  \nRelated Sections:  \n1. Division 3 Sections: Installing inserts, sleeves and anchors in concrete.  \n2. Division 5 Sections:  \na. Providing hoist beams, steel framing, auxiliary support steel and divider beams for supporting guide-rail brackets.  \nb. Grouting hoistway entrance sills and frames for passenger elevators. Providing structural steel door frames with extensions to beam above if required on hoistway sides and sills for freight elevators, including finish painting.  \n3. Division 9 Sections: Providing passenger elevator car finish flooring and field painting unfinished and shop primed ferrous materials.  \n4. Division 15 Sections:  \na. Sump pit and pump.  \nb. Heating and ventilating hoistways and machine rooms.  \n5. Division 16 Sections:  \na. Providing electrical service to elevators, including fused disconnect switches.  \nb. Emergency power supply, transfer switch and auxiliary contacts.  \nc. Heat and smoke sensing devices.  \nd. Convenience outlets and illumination in machine room, hoistway and pit.  \nSubmittals  \nProduct data: When requested, submit product data for the following:  \n1. Elevator car enclosures and hoistway entrances.  \n2. Operation, control, and signal systems.  \nShop drawings:  \n1. Show equipment arrangement in the machine room, pit and hoistway. Provide plans, elevations, sections and details of assembly, erection, anchorage, and equipment location.  \n2. Indicate elevator system capacities, sizes, performances, safety features, finishes and other pertinent information.  \n3. Show floors served, travel distances, maximum loads imposed on the building structure at points of support and all similar considerations of the elevator work.  \n4. Indicate electrical power requirements and branch circuit protection device recommendations.  \nColor selection: Submit color charts of exposed finishes and materials for color selection.  \n1. When requested, submit samples of exposed finishes and materials selected for the elevator system materials and components.  \nCertificates: Inspection and acceptance certificates of elevator system installation.  \nOperation and maintenance data. Include the following:  \n1. Operation and maintenance instructions.  \n2. Parts list, with recommended parts inventory.  \nQuality Assurance  \nManufacturer Qualifications: An approved manufacturer regularly engaged in manufacturing, installing, and servicing elevators of the type required for the project.  \n1. The manufacturer of the machine, controller, signal fixtures, door operators cab, entrances , and all other major parts of the elevator operating equipment.  \na. The major parts of the elevator equipment shall be manufactured in the United States, and not be an assembled system.  \n2. The manufacturer shall have a documented, on-going quality assurance program. Installer Qualifications: The manufacturer or an authorized agent of the manufacturer with not less than five years of satisfactory experience installing elevators equal in character and performance to the project elevators.  \nRegulatory Requirements:  \n1. ASME A17 .1 Safety Code for Elevators and Escalators, latest edition or as required by the local building code.  \n2. International Building Code.  \n3. NFPA 70 National Electrical Code.  \n4. NFPA 80 Fire Doors and Windows.  \n5. Texas Accessibility Standards (TAS) .  \n6. Texas Department of Licensing and Regulation, Elevator Divis","cbCaigzeQ1wq6GIi","https://ap.wps.com/l/cbCaigzeQ1wq6GIi","pdf",181953,15,"English","# General\n## Summary\n# Submittals\n## Product data\n## Shop drawings\n## Color selection\n## Certificates\n## Operation and maintenance data\n# Quality Assurance\n## Manufacturer qualifications\n## Installer qualifications\n# Regulatory Requirements\n## Fire-rated entrance assemblies\n## Inspection and testing\n# Delivery, Storage And Handling\n# Project Conditions\n## Painting\n# Warranty\n# Maintenance","[{\"question\":\"What elevator components and systems are included in the hydraulic elevator scope?\",\"answer\":\"The scope includes hydraulic passenger elevators and passenger work, elevator car enclosures, hoistway entrances, signal equipment, jacks, operation and control systems, accessibility provisions, and all equipment and devices needed for safe rated operation.\"},{\"question\":\"What submittals are required before installation?\",\"answer\":\"When requested, product data for car enclosures and hoistway entrances must be submitted, along with shop drawings showing equipment arrangement and capacities, performances, safety features, finishes, floor coverage, travel distances, and electrical power requirements. Color charts, samples, certificates, and operation and maintenance data are also required.\"},{\"question\":\"Which standards and regulatory requirements govern safety and fire-related elements?\",\"answer\":\"The specification requires compliance with ASME A17.1, International Building Code, NFPA 70, NFPA 80, Texas Accessibility Standards, and Texas Department of Licensing and Regulation requirements. Fire-rated entrance assemblies must comply with ASTM E152, UL 10B, and NFPA 80, with UL Class B labels or equivalent.\"}]","Hydraulic Elevators - Appendix 14-A - Hydraulic Elevator Installation & Safety Requirements | PDF",38]