[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-664335-105":59,"doc-detail-664335-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","hx30g-operators-manual-issue-10-original-instruction","HX30G Operator’s Manual - Issue 1.0 - Original Instruction","","HX30G operator’s manual provides machine overview and intended use for a self-contained vacuum excavation system that vacuums nonhazardous, nonflammable liquid and solid debris. It describes applications such as soft excavation, exposing utilities for visual verification, potholing, and an optional reverse-flow system for transferring spoils. The manual sets operational temperature limits, requires professional service, outlines equipment modification restrictions, lists key machine components for different tank configurations, and includes regulatory and RF exposure compliance notices.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/hx30g-operators-manual-issue-10-original-instruction/664335/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/hx30g-operators-manual-issue-10-original-instruction/664335.png","ImageObject",300,407,{"name":92,"@type":93},"I feel Different","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the intended use of the HX30G machine?","Question",{"text":112,"@type":113},"The HX30G is intended for soft excavation and vacuuming nonhazardous, nonflammable liquid and solid debris, including exposing utilities for visual verification and potholing. The optional reverse flow system transfers spoils to another tank.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What temperature range does the manual specify for operation?",{"text":117,"@type":113},"Operate in ambient temperatures from 10°F to 115°F (-12°C to 46°C). For extreme temperatures, contact the Ditch Witch dealer for required provisions.",{"name":119,"@type":110,"acceptedAnswer":120},"Can the equipment be modified by users?",{"text":121,"@type":113},"Equipment modification may violate applicable standards and regulations and could affect proper operation. Modifications should be made only by competent personnel with knowledge of relevant standards, requirements, and specialized training.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},664335,1793251648,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},962093541761,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","HX30G  \nBriggs & Stratton Vanguard  \nOperator’s Manual  \nCMW®  \nIssue 1.0 Original Instruction  \n053-3227  \nOverview  \nChapter Contents Serial Number Location ..................... 2  \nIntended Use .............................. 3  \nEquipment Modification .................... 3  \nMachine Components ...................... 4  \n• 500-gal (1893L) tank on VT9/VT9H .............................. 4  \n• 500-gal (1893L) tank on VT12/VT14 & 800-gal (3028L) tank .......... 5  \nRegulatory Notices ......................... 6  \n• United States ................................................ 6  \n• Canada ..................................................... 6  \n• RF Exposure Statement ....................................... 6  \nOperator Orientation ....................... 7  \nOperating Area ............................ 7  \nAbout This Manual ......................... 8  \n• Bulleted Lists ................................................ 8  \n• Numbered Lists .............................................. 8  \nCalifornia Proposition 65  \n The engine exhaust from this product contains chemicals known to the State of California  \nto cause cancer, birth defects, and other reproductive [harm. ](harm.  www.P65warnings.ca.gov)[ www.P65warnings.ca.go](harm.  www.P65warnings.ca.gov)[v](harm.  www.P65warnings.ca.gov).  \nOverview-2 HX30G Operator’s Manual  \nSerial Number Location  \nSerial Number Location  \nRecord serial numbers and date of purchase in spaces provided. Serial number is located as shown.  \nj81om001h19.eps  \nItem  \nDate of manufacture  \nDate of purchase  \nMachine serial number  \nHX30G Operator’s Manual Overview-3  \nIntended Use  \nIntended Use  \nThe HX30G is a self-contained vacuum excavation machine capable of vacuuming a wide variety of nonhazardous, non-flammable liquid and solid debris. It is designed to perform efficient soft excavation, including exposing utilities for visual verification and potholing. The optional reverse flow system allows for spoils transfer to another tank.  \nThis machine is intended for operation only according to the instructions in this manual. Operate machine in ambient temperatures from 10° to 115°F (-12° to 46°C) . Contact your Ditch Witch® dealer for provisions required for operating in extreme temperatures. Use in any other way is considered contrary to the intended use.  \nThis machine should be operated, serviced, and repaired only by professionals familiar with its particular characteristics and acquainted with the relevant safety procedures.  \nEquipment Modification  \nThis equipment was designed and built in accordance with applicable standards and regulations. Modification of equipment could mean that it will no longer meet regulations and may not function properly or in accordance with the operating instructions. Modification of equipment should only be made by competent personnel possessing knowledge of applicable standards, regulations, equipment design functionality/requirements and any required specialized training.  \nOverview-4 HX30G Operator’s Manual  \nMachine Components  \nMachine Components  \n500-gal (1893L) Tank on VT9/VT9H  \n1  \n7  \n2 3 4 5 6  \n12 8 9 10 11  \nj81om002h19.eps  \n1. Inlet valve  \n2. Primary shutoff valve  \n3. Debris tank  \n4. Antifreeze tank  \n5. Power pack  \n6. Operator station  \n7. Hose reel  \n8. Water tank  \n9. Vacuum filter  \n10. Potholing tools  \n11. Drain/Outlet valve  \n12. Wash wand  \nHX30G Operator’s Manual Overview-5  \nMachine Components  \n500-gal (1893L) Tank on VT12/VT14 &  \n800-gal (3028L) Tank  \n1 2 3 4 5 6  \n7 13 8 9 10 11 12  \nj81om003h19.eps  \n1. Inlet valve  \n2. Primary shutoff valve  \n3. Debris tank  \n4. Water tank  \n5. Power pack  \n6. Operator station  \n7. Hose reel  \n8. Antifreeze tank  \n9. Cyclonic filter  \n10. Vacuum filter  \n11. Potholing tools  \n12. Drain/Outlet valve  \n13. Wash wand  \nOverview-6 HX30G Operator’s Manual  \nRegulatory Notices  \nRegulatory Notices  \nUnited States  \nThis device complies with Part 15 of the FCC Rules. Operation is subject to th","cbCaiv5IaZMi66SR","https://ap.wps.com/l/cbCaiv5IaZMi66SR","pdf",19530220,141,"English","# Overview\n## Intended Use\n## Equipment Modification\n## Machine Components\n## Regulatory Notices\n## Operator Orientation\n# About This Manual","[{\"question\":\"What is the intended use of the HX30G machine?\",\"answer\":\"The HX30G is intended for soft excavation and vacuuming nonhazardous, nonflammable liquid and solid debris, including exposing utilities for visual verification and potholing. The optional reverse flow system transfers spoils to another tank.\"},{\"question\":\"What temperature range does the manual specify for operation?\",\"answer\":\"Operate in ambient temperatures from 10°F to 115°F (-12°C to 46°C). For extreme temperatures, contact the Ditch Witch dealer for required provisions.\"},{\"question\":\"Can the equipment be modified by users?\",\"answer\":\"Equipment modification may violate applicable standards and regulations and could affect proper operation. Modifications should be made only by competent personnel with knowledge of relevant standards, requirements, and specialized training.\"}]","HX30G Operator’s Manual - Issue 1.0 - Original Instruction | PDF",355]