[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-662252-105":3,"doc-detail-662252-en":81,"detail-sidebar-cat-0-en-105":97},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","hvls-install-manual-july-2022","HVLS INSTALL MANUAL - July 2022","","HVLS fan installation manual covering safety requirements, tools, contents, pre-installation checks, and detailed step-by-step procedures. Includes guidance for mounting, retention system setup, motor and VFD control panel assembly, guy wire installation, and blade installation. Provides reference sections on electrical wiring, fan network configurations, fire panel integration, line filter considerations, maintenance practices, and troubleshooting steps to support compliant and reliable commissioning.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/hvls-install-manual-july-2022/662252/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/hvls-install-manual-july-2022/662252.png","ImageObject",300,407,{"name":42,"@type":43},"OKfine","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",6,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What must be done before installing or servicing the fan to prevent electric shock?","Question",{"text":63,"@type":64},"Always disconnect power by turning off the circuit breaker(s) to the fan locations and confirm Lockout/Tagout procedures are in place. If breakers cannot be locked, attach a prominent warning device such as a tag to the electrical panel.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How should the retention cable be installed?",{"text":68,"@type":64},"Attach the Retention Cable to the fan motor and secure it to the building structure on EVERY fan. Install it according to Hunter Industrial specifications to help limit the fan’s fall distance in an unlikely mounting failure event.",{"name":70,"@type":61,"acceptedAnswer":71},"What wiring and code compliance requirements apply?",{"text":72,"@type":64},"All wiring must follow national and local electrical codes, including ANSI/NFPA 70, and must be installed only by qualified technicians familiar with the National Electrical Code and local codes. The installer is responsible for meeting relevant product certifications, listings, and building regulations.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},662252,1793207537,{"code":4,"msg":82,"data":83},"success",{"doc_id":79,"user_id":84,"nickname":42,"user_avatar":85,"doc_module":4,"category_id":55,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":86,"file_id":87,"file_url":88,"file_type":89,"file_size":90,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":91,"language":92,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":93,"faqs":94,"seo_title":95,"seo_description":12,"update_tm":80,"read_time":96},962093957596,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","INSTALLATION MANUAL  \nAUTHENTICITY  \nContents  \nSafety & Precautions 3  \nFan Placement 6  \nTools Needed 8  \nIn The Box 9  \nPre-Installation Checklist 10  \nAdjustable Downrod 11  \nINSTALLATION  \nStep 1: Mounting 13  \nStep 2: Retention System 17  \nStep 3: Motor Assembly 18  \nStep 4: VFD Control Panel 19  \nStep 5: Guy Wires 20  \nStep 6: Blade Installation 22  \nREFERENCE  \nElectrical 24  \nFan Network Configurations 27  \nFire Panel 31  \nLine Filter 33  \nMaintenance 36  \nTroubleshooting 37  \nLEGACY  \nThe Hunter legacy is not only about quality—it’s about longevity. We invented the ceiling fan. We build fans that last, fans that are designed as fans. We design our fans while considering each person in the process—from the installer to the owner .  \nIn a world full of impersonators, be an original. We invented the ceiling fan, and we stand behind our products.  \n  BEFORE YOU BEGIN  \n!  \nBEFORE YOU BEGIN  \nSAFETY & PRECAUTIONS  \nImportant Safety Information  \nTo prevent SERIOUS INJURY, DEATH, and PROPERTY DAMAGE, you should read, understand, and follow the warnings and instructions in this manual before installing or operating the fan.  \nREAD AND SAVE THESE INSTRUCTIONS. This manual must always be kept with the fan and should remain with the fan if it is transferred or sold. Always give manual to fan owner following installation.  \nFIRE, ELECTRIC SHOCK AND CRUSH HAZARDS.  \nTO PREVENT SERIOUS INJURY OR DEATH:  \n• ALWAYS mount fan directly from building structure that can withstand double the maximum hanging fan weight and install the Retention Cable.  \n• BEFORE installing or servicing your fan, ALWAYS disconnect the power by turning off the circuit breaker or breakers to the fan locations. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the electrical panel.  \n• All wiring must be in accordance with national and local electrical codes, including ANSI/NFPA 70. If you are unfamiliar with wiring or are in doubt, consult a qualified electrician.  \n• DO NOT install fan to be used in the presences of flammable vapors and gasses or in environments where combustible dust is present.  \n• DO NOT bend the blades or blade holders when installing or cleaning the fan.  \n• DO NOT insert foreign objects in between rotating fan blades.  \nInstallation, adjustment, repair, or maintenance must be performed by qualified personnel.  \nFollow all safety practices and instructions during the installation, operation, and servicing of the fan. Failure to apply these safety practices could result in death or serious injury. If you do not understand the instructions, please call our Technical Department at 1-844-593-FANS (3267) for guidance.  \nAlways check federal, state, and local codes before installing fan.  \nCode compliance is the responsibility of the installer. Check all relevant codes to make sure that all product certifications, product listings, and building regulations are met.  \nProfessional installation practice requires following local utility company guidelines for connecting to AC mains. This unit is for professional use only and is not required to comply with EN 61000-3-2:2006. This fan conforms to ANSI/UL standard 507, Electric Fans and is certified to CSA STD C22 .2 No. 113, Fans & Ventilators.  \n5007479 CONFORMS TO UL STD 507 CERTIFIED TO CAN/CSA STD C22 .2 NO. 113  \n3  \nBEFORE YOU BEGIN  \nSAFETY & PRECAUTIONS  \n ELECTRIC SHOCK HAZARD  \nTO PREVENT SERIOUS INJURY OR DEATH:  \n• BEFORE installing or servicing your fan, ALWAYS disconnect the power by turning off the circuit breaker or breakers, to the fan locations and confirm Lockout/Tagout procedures are in place. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the electrical panel.  \n• All wiring must be in accordance with national and local electrical codes, including ANSI/NFPA 70. If you are unfamiliar with wiring or in doubt, consult a qualified e","cbCaio1ukxHRVIrZ","https://ap.wps.com/l/cbCaio1ukxHRVIrZ","pdf",16014907,40,"English","# Safety & Precautions\n## Fire, Electric Shock and Crush Hazards\n# Fan Placement\n# Tools Needed\n# In The Box\n# Pre-Installation Checklist\n# Adjustable Downrod\n# Installation\n## Step 1: Mounting\n## Step 2: Retention System\n## Step 3: Motor Assembly\n## Step 4: VFD Control Panel\n## Step 5: Guy Wires\n## Step 6: Blade Installation\n# Reference\n## Electrical\n## Fan Network Configurations\n## Fire Panel\n## Line Filter\n## Maintenance\n## Troubleshooting","[{\"question\":\"What must be done before installing or servicing the fan to prevent electric shock?\",\"answer\":\"Always disconnect power by turning off the circuit breaker(s) to the fan locations and confirm Lockout/Tagout procedures are in place. If breakers cannot be locked, attach a prominent warning device such as a tag to the electrical panel.\"},{\"question\":\"How should the retention cable be installed?\",\"answer\":\"Attach the Retention Cable to the fan motor and secure it to the building structure on EVERY fan. Install it according to Hunter Industrial specifications to help limit the fan’s fall distance in an unlikely mounting failure event.\"},{\"question\":\"What wiring and code compliance requirements apply?\",\"answer\":\"All wiring must follow national and local electrical codes, including ANSI/NFPA 70, and must be installed only by qualified technicians familiar with the National Electrical Code and local codes. The installer is responsible for meeting relevant product certifications, listings, and building regulations.\"}]","HVLS INSTALL MANUAL - July 2022 | PDF",101,{"code":4,"msg":82,"data":98},[99,103,107,111,116,119,123,128,133,136,140],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":100,"show_sort_weight":101,"slug":102},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":104,"show_sort_weight":105,"slug":106},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},"Exam",70,"exam",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":113,"show_sort_weight":114,"slug":115},5,"Comic",60,"comic",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":117,"slug":118},50,"technology",{"id":120,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":91,"slug":122},7,"Healthcare","healthcare",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":126,"slug":127},8,"Research & Report",30,"research-report",{"id":129,"doc_module":4,"doc_module_name":25,"category_name":130,"show_sort_weight":131,"slug":132},9,"Religion & Spirituality",20,"religion-spirituality",{"id":131,"doc_module":4,"doc_module_name":25,"category_name":134,"show_sort_weight":131,"slug":135},"World Cup","world-cup",{"id":137,"doc_module":4,"doc_module_name":25,"category_name":138,"show_sort_weight":137,"slug":139},10,"Lifestyle","lifestyle",{"id":141,"doc_module":4,"doc_module_name":25,"category_name":142,"show_sort_weight":112,"slug":143},19,"General","general"]