[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-182400-105":3,"detail-sidebar-cat-0-en-105":85,"doc-detail-182400-en":134},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":78,"head_meta":80,"extra_data":82,"updated_unix":84},105,"en","hvac-first-second-floor-plan-permit-drawings","HVAC - First & Second Floor Plan - Permit Drawings","","HVAC许可与施工范围文件，用于将公寓用途变更为短期酒店，并提出新的空调设备与空气分配要求。内容包含电机/手动风门与室外新风管布置、排风管与屋顶排出、冷凝水管与干井设置、制冷剂管线敷设及必要的检查与现场协调指引。文件还给出燃烧空气计算基准与能耗控制说明，要求分时温控与下班后系统停机、新风与风门在无人使用时的关闭策略。",{"@graph":14,"@context":77},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/hvac-first-second-floor-plan-permit-drawings/182400/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/hvac-first-second-floor-plan-permit-drawings/182400.png","ImageObject",300,407,{"name":42,"@type":43},"Paura","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-08","2026-09-02",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",9,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69,73],{"name":60,"@type":61,"acceptedAnswer":62},"该文件的主要用途是什么？","Question",{"text":63,"@type":64},"用于HVAC许可与施工范围说明，支持将公寓建筑用途变更为短期酒店，并配置新的空调设备与空气分配。","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"HVAC安装与材料方面有哪些关键要求？",{"text":68,"@type":64},"要求按计划设置排风与新风相关管道、风门（电动/手动/可编程温控控制）、冷凝水管与干井，并对风管保温与冷凝水线敷设提出要求。",{"name":70,"@type":61,"acceptedAnswer":71},"能耗控制有哪些具体措施？",{"text":72,"@type":64},"要求所有HVAC设备具备可编程温控，以便在运行结束后停机；照明与空调均需在无人使用时通过室外空气电动风门等措施实现关闭。",{"name":74,"@type":61,"acceptedAnswer":75},"燃烧空气计算在文件中如何体现？",{"text":76,"@type":64},"提供基于FBC-GAS机械燃烧空气的供应最低值与计算逻辑，并列出与燃气热水器相关的燃烧空气需求与总量。","https://schema.org",{"og:url":32,"og:type":79,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":81,"canonical":32},"index,follow",{"doc_id":83,"site_id":7},182400,1788348467,{"code":4,"msg":86,"data":87},"success",[88,92,96,100,105,109,114,119,123,126,130],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},"Exam",70,"exam",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},5,"Comic",60,"comic",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":107,"slug":108},6,50,"technology",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},7,"Healthcare",40,"healthcare",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},8,"Research & Report",30,"research-report",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":121,"slug":122},"Religion & Spirituality",20,"religion-spirituality",{"id":121,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":121,"slug":125},"World Cup","world-cup",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":127,"slug":129},10,"Lifestyle","lifestyle",{"id":131,"doc_module":4,"doc_module_name":25,"category_name":132,"show_sort_weight":101,"slug":133},19,"General","general",{"code":4,"msg":86,"data":135},{"doc_id":83,"user_id":136,"nickname":42,"user_avatar":137,"doc_module":4,"category_id":106,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":138,"file_id":139,"file_url":140,"file_type":141,"file_size":142,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":22,"language":143,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":144,"faqs":145,"seo_title":146,"seo_description":12,"update_tm":84,"read_time":30},13056712833777,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","| CLIENT:  \u003Cbr>24177   \u003Cbr>Issued for  \u003Cbr>2417  \u003Cbr>Miami Bea   |\n| --- |\n\nSTREET  \nPermitting  \n7 street  \nch,FL 33141  \nPROPERTYLINE  \n# 407 LINCOLN ROAD,SUITE 2C\n\nMIAMI BEACH,FL33139  \nTel:786.218.5335  \n## License \\#AA 26002467\n\n\n| WWW.CASTELLANOSDESIGN.COM   |\n| --- |\n|  |\n| No.DATE ISSUED/REVISED   |\n| 本  \u003Cbr>17 FEB/15 PERMITTING  \u003Cbr>RTC  \u003Cbr>12-3-15   |\n|  |\n|  |\n|  |\n|  |\n|  |\n|  |\n|  |\n|  |\n| ALLDRAWN AND WRITTEN MATERIAL CONTAINED HEREIN IS THE SOLE  \u003Cbr>PROPERTY OF CASTELLANOS DESIGN STUDIO.LLC.AND MAY NOT BE  \u003Cbr>DUPLICATED,PUBLISHED,DISCLOSED OR USED WITHOUT EXPRESS WRITTEN  \u003Cbr>CONSENT OF CASTELLANOS DESIGN STUDIO,LLC.  \u003Cbr>THE DRAWINGS ARE SCOPE DOCUMENTS WHICH INDICATE THE GENERAL  \u003Cbr>SCOPE OF WORK,AND SUCH,DO NOT NECESSARILY DESCRIBE ALL WORK  \u003Cbr>REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE WORK.  \u003Cbr>GENERAL CONTRACTOR IS TO FURNISH AND INSTALLALLITEMS REQUIRED  \u003Cbr>FOR THE PROPER COMPLETION OF ITS WORK WITHOUT ADJUSTMENT TO  \u003Cbr>THE CONTRACT AMOUNT UNLESS SCOPE OF WORK CHANGES FROM THAT  \u003Cbr>INDICATED ON THE DRAWINGS.IN THE EVENT OF A CONFLICT WITHIN OR  \u003Cbr>AMONG THE CONTRACT DOCUMENTS.THAT DOCUMENT PLACING THE  \u003Cbr>GREATEST BURDEN UPON GENERAL CONTRACTOR SHALLGOVERN.THE  \u003Cbr>GENERAL CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE ALL  \u003Cbr>DRAWINGS,REPORTING ANY ERROR.INCONSISTENCY OR OMISSIONHE MAY  \u003Cbr>DISCOVER AND REPORT TO CDS AND IN NO CASE SHALL PROCEED IN  \u003Cbr>UNCERTAINTY.   |\n|  |\n|  |\n|  |\n| SEAL:  \u003Cbr>WESLEY ART CASTELLANOS  \u003Cbr>FLORIDA ARCHITECT LICENSE AR 96133   |\n|  |\n|  |\n|  |\n| PROJECT NO:2014-32   |\n| HVAC   |\n| FIRST &SECOND  \u003Cbr>FLOOR  \u003Cbr>PLAN   |\n|  |\n| CHECKED BY:O.F.  \u003Cbr>SHEET NO:   |\n| DRAWN BY:O.F.  \u003Cbr>M-1.1  \u003Cbr>SCALE:AS NOTED  \u003Cbr>2015 BY CDS   |\n|  |\n|  |\n\n| HVAC NOTES:  \u003Cbr>⑭EXHAUST DUCT AS SIZED ON PLAN TO WALL CAP.  \u003Cbr>①  WALL MOUNT PROGRAMMABLE THERMOSTAT AT 50”A.F.F.  \u003Cbr>PROVIDE CORROSION RESISTANT SCREEN.  \u003Cbr>(2)VERTICAL MOUNT AIR HANDLER UNIT(AHU),AS SIZED ON  \u003Cbr>PLAN.ALLOW MINIMUM 6”AROUND AHU.INSTALLATION  \u003Cbr>NEW HOOD 200CFM,PROVIDE EXHAUST DUCT TERMINATED  \u003Cbr>⑮  \u003Cbr>AND SERVICE CLEARANCES AS PER MANUFACTURER  \u003Cbr>IN WALL PACK WITH BIRD SCREEN AND BACK DRAFT  \u003Cbr>SPECIFICATIONS.  \u003Cbr>DAMPER.  \u003Cbr>③CONCRETE PAD MOUNTED CONDENSING UNIT ABOVE FLOOD  \u003Cbr>⑯  \u003Cbr>CONDENSATE PUMP(CP),SEE SPECS.ON SCHEDULES  \u003Cbr>LEVEL.TIE DOWN SHALL BE MIAMI-DADE APPROVED.  \u003Cbr>SHEET.  \u003Cbr>④PROVIDE MOTORIZED DAMPER(MD).MD CLOSED WHEN  \u003Cbr>⑰PTAC HEAT PUMP UNIT,RUN CONDENSATE LINE ON WALL  \u003Cbr>SPACE IS NOT IN USED.  \u003Cbr>DOWN TO DRY WELL.FIELD COORDINATE.  \u003Cbr>⑤PROVIDE MANUAL VOLUME DAMPER.TYPICAL.  \u003Cbr>18 EXHAUST DUCT AS SIZED ON PLAN UP TO ROOF CAP.  \u003Cbr>⑥OUTSIDE_AIR(0/A)DUCT,AS SIZED ON PLAN  \u003Cbr>PROVIDE CORROSION RESISTANT SCREEN.  \u003Cbr>TERMINATING WITH WALL LOUVER,BASE ON RUSKIN  \u003Cbr>TWO 18X18 VENTILATION LOUVER,ONE @12”A.F.F.AND ONE @  \u003Cbr>EME520MD,NOA 12-0816.01,MINIMUM FREE AREA 0.25.  \u003Cbr>⑲  \u003Cbr>PROVIDE CORROSION RESISTANT SCREEN.O/A SHALL BE  \u003Cbr>12”BELOW ROOF DECK,REFER TO DETAIL.  \u003Cbr>MINIMUM 10'AWAY FROM ANY EXHAUST OR VENT.FIELD  \u003Cbr>1  \u003Cbr>VERIFY/COORDINATE FINAL LOCATION.   |  |  |  |\n| --- | --- | --- | --- |\n| ⑦DUCTWORK TO BE RIGID FIBER GLASS DUCT BOARD 1.5”  \u003Cbr>THICK(R-6).  \u003Cbr>⑧INSULATED CONDENSATE LINE,AS SIZED ON PLAN,AT  \u003Cbr>CEILING.  \u003Cbr>⑨DRY-WELL FOR CONDENSATE COLLECTION.FIELD  \u003Cbr>VERIFY/COORDINATE FINAL LOCATION.  \u003Cbr>⑩REFRIGERANT LINES AT CEILING TO CONDENSER UNIT(CU).  \u003Cbr>①FULL LOUVERED DOOR FOR RETURN AIR.NO COMBUSTIBLES  \u003Cbr>ALLOWED.  \u003Cbr>⑫1”DOOR UNDER CUT.TYPICAL.  \u003Cbr>13 CEILING EXHAUST FAN &GRILLE W/BACKDRAFT DAMPER AS  \u003Cbr>SIZED ON PLAN.   | COMBUSTION AIR CALCULATION:  \u003Cbr>FBC-GAS.2014304.9 MECHANICAL COMBUSTION AIR  \u003Cbr>SUPPLY MINIMUM 0.35 CFM PER 1,000 BTU/HR.  \u003Cbr>400,000 BTU  \u003Cbr>GAS WATER HETER  \u003Cbr>140 CFM.  \u003Cbr>TOTAL COMBUSTION AIR:   |  |  |\n|  | SCOPE OF WORK:  \u003Cbr>CHANGE OF USE FROM APARTMENT BUILDING TO SHORT TERM  \u003Cbr>HOTEL.NEW AC EQUIPMENT AND NEW AIR DISTRIBUTION.   |  |  |\n|  | ENERGY CONSERVATION NOTES:  \u003Cbr>ALL HVAC EQUIPME","cbCaiqRjR2pcDChv","https://ap.wps.com/l/cbCaiqRjR2pcDChv","pdf",3155967,"English","# HVAC Notes\n## HVAC Notes（排风、冷凝水、风门与新风）\n# Combustion Air Calculation\n# Scope of Work\n# Energy Conservation Notes","[{\"question\":\"该文件的主要用途是什么？\",\"answer\":\"用于HVAC许可与施工范围说明，支持将公寓建筑用途变更为短期酒店，并配置新的空调设备与空气分配。\"},{\"question\":\"HVAC安装与材料方面有哪些关键要求？\",\"answer\":\"要求按计划设置排风与新风相关管道、风门（电动/手动/可编程温控控制）、冷凝水管与干井，并对风管保温与冷凝水线敷设提出要求。\"},{\"question\":\"能耗控制有哪些具体措施？\",\"answer\":\"要求所有HVAC设备具备可编程温控，以便在运行结束后停机；照明与空调均需在无人使用时通过室外空气电动风门等措施实现关闭。\"},{\"question\":\"燃烧空气计算在文件中如何体现？\",\"answer\":\"提供基于FBC-GAS机械燃烧空气的供应最低值与计算逻辑，并列出与燃气热水器相关的燃烧空气需求与总量。\"}]","HVAC - First & Second Floor Plan - Permit Drawings | PDF"]