[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-652008-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-652008-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","husky-15120-air-operated-diaphragm-pump-instructions","Husky 15120 Air-Operated Diaphragm Pump - Instructions","","Operation instructions for the Graco Husky 15120 air-operated diaphragm pump (3A2888C EN), covering professional fluid transfer use and essential safety requirements. The manual emphasizes maximum working pressure limits, grounding and air-line handling, and safe procedures to prevent fire and explosion, including eliminating ignition sources and proper ventilation. It also details pressurized equipment hazards, the need to perform the pressure relief procedure before cleaning or servicing, and daily checks of hoses and connections to reduce injury and equipment misuse risk.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/husky-15120-air-operated-diaphragm-pump-instructions/652008/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/husky-15120-air-operated-diaphragm-pump-instructions/652008.png","ImageObject",300,407,{"name":42,"@type":43},"Maya Linwood","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-29","2026-10-24",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",7,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the maximum working pressure for the Husky 15120 pump?","Question",{"text":63,"@type":64},"The manual states a maximum working pressure of 125 psi (0.86 MPa, 8.6 bar).","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"Why is grounding of equipment and use of grounded hoses emphasized?",{"text":68,"@type":64},"To prevent static-related hazards that can build up on plastic parts during cleaning and potentially discharge and ignite flammable vapors, supporting safer fire and explosion prevention.",{"name":70,"@type":61,"acceptedAnswer":71},"What should be done before cleaning, checking, or servicing the equipment?",{"text":72,"@type":64},"Follow the Pressure Relief Procedure when stopping spraying/dispensing and before performing any cleaning, inspection, or servicing.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},652008,1792912398,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,105,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":103,"slug":104},6,50,"technology",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":102,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":99},962084928432,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Operation  \nHusky ™ 15120 Air-Operated Diaphragm Pump  \n3A2888C EN  \nPolypropylene or PVDF pumps for fluid transfer applications. For professional use only. Not for use in European explosive atmosphere locations.  \nImportant Safety Instructions  \nRead all warnings and instructions in this manual and in your Repair/Parts manual.  \nSave these instructions.  \nMaximum Working Pressure: 125 psi (0. 86 MPa, 8.6 bar)  \nPROVEN QUALITY. LEADING TECHNOLOGY.  \nContents  \nWarnings ........................................................... 3  \nOrdering Information ........................................... 6  \nRelated Manuals ................................................ 6  \nConfiguration Number Matrix ............................... 7  \nInstallation .......................................................... 8  \nGeneral Information ..................................... 8  \nTighten Fasteners ........................................ 8  \nTips to Reduce Cavitation............................. 8  \nMount the Pump .......................................... 8  \nGround The System ..................................... 10  \nAir Lines ...................................................... 10  \nAir Exhaust Ventilation ................................. 11  \nFluid Supply Line ......................................... 12  \nFluid Outlet Line........................................... 12  \nFlange Connections ..................................... 13  \nOperation ........................................................... 14  \nPressure Relief Procedure ............................ 14  \nTighten Fasteners ........................................ 14  \nFlush the Pump Before First Use .................. 14  \nStart and Adjust the Pump ............................ 14  \nPump Shutdown .......................................... 14  \nMaintenance ...................................................... 15  \nMaintenance Schedule ................................. 15  \nLubrication................................................... 15  \nTighten Threaded Connections ..................... 15  \nFlushing and Storage ................................... 15  \nTorque Instructions ............................................. 16  \nPerformance Charts ............................................ 17  \nDimensions ........................................................ 20  \nTechnical Data ................................................... 22  \nGraco Standard Husky Pump Warranty................ 24  \n2 3A2888C  \nWarnings  \nWarnings  \nThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.  \n\n|  WARNING |  |\n| --- | --- |\n| \u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>| FIRE AND EXPLOSION HAZARD\u003Cbr>Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:\u003Cbr>• Use equipment only in well ventilated area.\u003Cbr>• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc) .\u003Cbr>• Keep work area free of debris, including solvent, rags and gasoline.\u003Cbr>• Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.\u003Cbr>• Ground all equipment in the work area. See Grounding instructions.\u003Cbr>• Use only grounded hoses.\u003Cbr>• Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless they are antistatic or conductive.\u003Cbr>• Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment until you identify and correct the problem.\u003Cbr>• Keep a working fire extinguisher i","cbCaivcUTGXsrGbp","https://ap.wps.com/l/cbCaivcUTGXsrGbp","pdf",2745108,24,"English","# Warnings\n# Ordering Information\n# Related Manuals\n# Configuration Number Matrix\n# Installation\n## General Information\n## Tighten Fasteners\n## Tips to Reduce Cavitation\n## Mount the Pump\n## Ground The System\n## Air Lines\n## Air Exhaust Ventilation\n## Fluid Supply Line\n## Fluid Outlet Line\n## Flange Connections\n# Operation\n## Pressure Relief Procedure\n## Tighten Fasteners\n## Flush the Pump Before First Use\n## Start and Adjust the Pump\n## Pump Shutdown\n# Maintenance\n## Maintenance Schedule\n## Lubrication\n## Tighten Threaded Connections\n## Flushing and Storage\n## Torque Instructions\n# Performance Charts\n# Dimensions\n# Technical Data\n# Graco Standard Husky Pump Warranty","[{\"question\":\"What is the maximum working pressure for the Husky 15120 pump?\",\"answer\":\"The manual states a maximum working pressure of 125 psi (0.86 MPa, 8.6 bar).\"},{\"question\":\"Why is grounding of equipment and use of grounded hoses emphasized?\",\"answer\":\"To prevent static-related hazards that can build up on plastic parts during cleaning and potentially discharge and ignite flammable vapors, supporting safer fire and explosion prevention.\"},{\"question\":\"What should be done before cleaning, checking, or servicing the equipment?\",\"answer\":\"Follow the Pressure Relief Procedure when stopping spraying/dispensing and before performing any cleaning, inspection, or servicing.\"}]","Husky 15120 Air-Operated Diaphragm Pump - Instructions | PDF",1792877732]