[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-456335-105":59,"doc-detail-456335-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","hpat6002-handypat-instruction-manual-general-safety-information","HPAT600/2 HANDYPAT - InstructIon Manual - General Safety Information","","Safety and operation instructions for the battery-powered HPAT600/2 HANDYPAT portable appliance tester. Provides general safety information covering warning content, the importance of understanding and complying with procedures, and electrical shock prevention when working above specified voltage thresholds. Details safe use requirements, inspection and damage checks, protective measures, and end-of-life disposal guidance aligned with relevant EU directives. Includes symbol meanings, references for updated instructions, and introductory technical context for subsequent operation and testing sections.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/hpat6002-handypat-instruction-manual-general-safety-information/456335/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/hpat6002-handypat-instruction-manual-general-safety-information/456335.png","ImageObject",300,407,{"name":92,"@type":93},"Angel","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-08","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What safety precautions are emphasized before using the HPAT600/2 HANDYPAT?","Question",{"text":113,"@type":114},"The instructions stress that the warnings and operating instructions must be carefully read and fully understood. Failure to follow the warnings and procedures can lead to serious injury or even death.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How does the manual advise preventing electrical shock during testing?",{"text":118,"@type":114},"Proper safety measures are required when working with voltages exceeding 30V AC RMS, 42V AC peak, or 60V DC. The manual also recommends using applicable protective measures such as gloves and goggles.",{"name":120,"@type":111,"acceptedAnswer":121},"What do the warning and caution symbols in the manual indicate?",{"text":122,"@type":114},"The manual explains symbol meanings, including compliance with relevant EU directives, a caution to refer to accompanying documents, risk of electric shock, and disposal guidance at end of life according to EU directives.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},456335,1790981491,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":4},687207412472,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","HPAT600/2 HANDYPAT  \nInstructIon Manual  \nGENERAL SAFETY INFORMATION: Always read before proceeding.  \nWarning  \nThese instructions contain both information and warnings that are necessary for the safe operation and maintenance of this product. It is recommended that you read the instructions carefully and ensure that the contents are fully understood. Failure to understand and to comply with the warnings and instructions can result in serious injury, damage or even death.  \nIn order to avoid the danger of electrical shock, it is important that proper safety measures are taken when working with voltages exceeding 30V AC RMS, 42V AC peak or 60V DC.  \nThis product must only be used by a competent person capable of interpreting the results under the conditions and for the purposes for which it has been constructed. Particular attention should be paid to the Warnings, Precautions and Technical Specifications. Always check the unit is in good working order before use and that there are no signs of damage to it. Do not use if damaged.  \nWhere applicable other safety measures such as use of protective gloves, goggles etc. should be employed.  \nPlease keep these instructions for future reference. Updated instructions and product information are available at:  \n[www.martindale-electric.co.uk/instruct](www.martindale-electric.co.uk/instruct)  \nREMEMBER: SAFETY IS NO ACCIDENT  \nMEANING OF SYMBOLS:  \nEquipment complies with relevant EU Directives AC (Alternating Current)  \nCaution-refer to accompanying documents Caution-risk of electric shock  \nEnd of life disposal of this equipment should bein accordance with relevant EU Directives  \nThank you for buying one of our products. For safety and full understanding of its benefits please read this manual before use. Technical support is available from 01923 441717 and  \n[support@martindale-electric.co.uk](support@martindale-electric.co.uk).  \nCONTENTS  \n1 INTRODUCTION  \n1.1 Unpacking and Inspection 1  \n1.2 Description & Overview 1  \n2 GENERAL OPERATION & FUNCTIONS  \n2.1 Precautions 3  \n2.2 Power On/Off 4  \n2.3 Display Indicators 5  \n2.4 Connector Descriptions 5  \n2.5 Press Button Description 6  \n2.6 Contrast Adjustment 8  \n2.7 Default Settings and Pass Levels 8  \n2.8 User Specified Pass Level Range 8  \n2.9 Menu 9  \n2.10 Null of Test Probe Lead Resistance 9  \n2.11 Setting User Specified Pass Levels 10  \n2.12 Setting Insulation Test Voltage 10  \n2.13 Setting Auto/Manual Test Mode 11  \n2.14 Saving Test Data to Memory 11  \n2.15 Memory Full Screen 11  \n2.16 Recalling Test Data from Memory 12  \n2.17 Memory Empty Screen 12  \n2.18 Deleting Individual Test Data in Memory 12  \n2.19 Deleting All Test Data in Memory 13  \n2.20 Resetting to Default Settings and Pass Levels 14  \n2.21 Backlight 14  \n2.22 Battery Low Message 14 2.23 Auto Power Down 14 2.24 Charging Batteries 15  \n2.25 Inadvertent Connection of Mains 15 Supply Voltage  \n3 PERFORMING APPLIANCE & LEAD TESTS  \n3.1 Auto or Manual Test Mode? 16  \n3.2 Preliminary Checks and Set Up 17  \n3.3 IEC Lead Test 18  \n3.4 Class I Test 20  \n3.5 Class II Test 22  \n3.6 Simulated Load Test 25  \n3.7 Class I Earth Continuity Test 26  \n3.8 Class I Insulation Test 28  \n3.9 Class II Insulation Test 29  \n3.10 Extension Lead Testing 31  \n3.11 Fuse Check/Simulated Load Failure 33  \n3.12 Earth Continuity/Insulation Failure 32  \n3.13 Simulated Load Current Hi 34  \n3.14 Testing of 110V appliances 34  \n3.15 110V Extension Lead Testing 35  \n4 MAINTENANCE  \n4.1 Fitting Batteries 38  \n4.2 Calibration 38  \n4.3 Cleaning 39  \n4.4 Repair & Service 39  \n4.5 Storage Conditions 39  \n5 WARRANTY 40  \nTECHNICAL SPECIFICATION  \n1. INTRODUCTION  \n1.1 Inspection  \nExamine the shipping carton for any sign of damage. Inspect the unit and any accessories for damage. If there is any damage then consult your distributor immediately.  \nUnpack the HPAT600 and check that you have the following accessories:  \nInstructions Mains Charger Unit Car Charger  \nTest Probe with crocodile clip (TL67)  \n6 x AA ","cbCait2K9axiiG8z","https://ap.wps.com/l/cbCait2K9axiiG8z","pdf",1233689,48,"English","# 1 INTRODUCTION\n## 1.1 Unpacking and Inspection\n## 1.2 Description & Overview\n# 2 GENERAL OPERATION & FUNCTIONS\n## 2.1 Precautions\n## 2.2 Power On/Off\n## 2.3 Display Indicators\n## 2.4 Connector Descriptions\n## 2.5 Press Button Description\n## 2.6 Contrast Adjustment\n## 2.7 Default Settings and Pass Levels\n## 2.8 User Specified Pass Level Range\n## 2.9 Menu\n## 2.10 Null of Test Probe Lead Resistance\n## 2.11 Setting User Specified Pass Levels\n## 2.12 Setting Insulation Test Voltage\n## 2.13 Setting Auto/Manual Test Mode\n## 2.14 Saving Test Data to Memory\n## 2.15 Memory Full Screen\n## 2.16 Recalling Test Data from Memory\n## 2.17 Memory Empty Screen\n## 2.18 Deleting Individual Test Data in Memory\n## 2.19 Deleting All Test Data in Memory\n## 2.20 Resetting to Default Settings and Pass Levels\n## 2.21 Backlight\n## 2.22 Battery Low Message\n## 2.23 Auto Power Down\n## 2.24 Charging Batteries\n## 2.25 Inadvertent Connection of Mains Supply Voltage\n# 3 PERFORMING APPLIANCE & LEAD TESTS\n## 3.1 Auto or Manual Test Mode?\n## 3.2 Preliminary Checks and Set Up\n## 3.3 IEC Lead Test\n## 3.4 Class I Test\n## 3.5 Class II Test\n## 3.6 Simulated Load Test\n## 3.7 Class I Earth Continuity Test\n## 3.8 Class I Insulation Test\n## 3.9 Class II Insulation Test\n## 3.10 Extension Lead Testing\n## 3.11 Fuse Check/Simulated Load Failure\n## 3.12 Earth Continuity/Insulation Failure\n## 3.13 Simulated Load Current Hi\n## 3.14 Testing of 110V appliances\n## 3.15 110V Extension Lead Testing\n# 4 MAINTENANCE\n## 4.1 Fitting Batteries\n## 4.2 Calibration\n## 4.3 Cleaning\n## 4.4 Repair & Service\n## 4.5 Storage Conditions\n# 5 WARRANTY","[{\"question\":\"What safety precautions are emphasized before using the HPAT600/2 HANDYPAT?\",\"answer\":\"The instructions stress that the warnings and operating instructions must be carefully read and fully understood. Failure to follow the warnings and procedures can lead to serious injury or even death.\"},{\"question\":\"How does the manual advise preventing electrical shock during testing?\",\"answer\":\"Proper safety measures are required when working with voltages exceeding 30V AC RMS, 42V AC peak, or 60V DC. The manual also recommends using applicable protective measures such as gloves and goggles.\"},{\"question\":\"What do the warning and caution symbols in the manual indicate?\",\"answer\":\"The manual explains symbol meanings, including compliance with relevant EU directives, a caution to refer to accompanying documents, risk of electric shock, and disposal guidance at end of life according to EU directives.\"}]","HPAT600/2 HANDYPAT - InstructIon Manual - General Safety Information | PDF",1790745587,121]