[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-456332-105":59,"doc-detail-456332-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","hpat400-handypat-instruction-manual-general-safety-information","HPAT400 HANDYPAT - InstructIon Manual - GENERAL SAFETY INFORMATION","","HPAT400 HANDYPAT InstructIon Manual provides general safety guidance and operating procedures for a portable appliance tester used for insulation, IEC lead, and extension lead testing. It emphasizes precautions before use, including checking for cracks or damage, correct battery type installation, and avoiding contact with the appliance or probe during electrical tests. It also warns against improper mains connections, provides rules for safe operation under hazardous voltages, and explains key functions such as power control, display indicators, and selectable test sequences, supported by maintenance and warranty sections.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/hpat400-handypat-instruction-manual-general-safety-information/456332/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/hpat400-handypat-instruction-manual-general-safety-information/456332.png","ImageObject",300,407,{"name":92,"@type":93},"Kyle","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-07","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":52},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What must be checked before using the HPAT400 HANDYPAT?","Question",{"text":112,"@type":113},"Before use, inspect the unit for cracks or other damage and ensure it is free from dust, grease, and moisture. Also check associated leads and accessories, and do not use the unit if damaged.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What safety precautions are required during electrical testing?",{"text":117,"@type":113},"Do not touch the appliance being tested or the test probe tip while the HPAT400 is performing an electrical test. Where possible, use the provided crocodile clip to attach the probe to the appliance.",{"name":119,"@type":110,"acceptedAnswer":120},"How should the HPAT400 be powered on and powered off?",{"text":121,"@type":113},"To power on, hold down the green power button for at least 1 second and proceed to the SELECT TEST screen. To power off, again hold down the green power button for at least 1 second.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},456332,1791017007,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":52,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":4},3985741905716,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","HPAT400 HANDYPAT  \nInstructIon Manual  \nGENERAL SAFETY INFORMATION: Always read before proceeding.  \nWarning  \nThese instructions contain both information and warnings that are necessary for the safe operation and maintenance of this product. It is recommended that you read the instructions carefully and ensure that the contents are fully understood. Failure to understand and to comply with the warnings and instructions can result in serious injury, damage or even death.  \nIn order to avoid the danger of electrical shock, it is important that proper safety measures are taken when working with voltages exceeding 30V AC RMS, 42V AC peak or 60V DC.  \nThis product must only be used by a competent person capable of interpreting the results under the conditions and for the purposes for which it has been constructed. Particular attention should be paid to the Warnings, Precautions and Technical Specifications. Always check the unit is in good working order before use and that there are no signs of damage to it. Do not use if damaged.  \nWhere applicable other safety measures such as use of protective gloves, goggles etc. should be employed.  \nPlease keep these instructions for future reference. Updated instructions and product information are available at: www. [martindale-electric.co.uk/instruct](martindale-electric.co.uk/instruct)  \nREMEMBER: SAFETY IS NO ACCIDENT  \nMEANING OF SYMBOLS:  \nEquipment complies with relevant EU Directives AC (Alternating Current)  \nCaution-refer to accompanying documents Caution-risk of electric shock  \nEnd of life disposal of this equipment should bein accordance with relevant Local Directives  \nThank you for buying one of our products. For safety and full understanding of its benefits please read this manual before use.  \nCONTENTS  \n1 INTRODUCTION  \n1.1 Unpacking and Inspection 1  \n1.2 Description & Overview 1  \n2 GENERAL OPERATION & FUNCTIONS  \n2.1 Precautions 3  \n2.2 Power On/Off 4  \n2.3 Display Indicators 4  \n2.4 Connector Descriptions 5  \n2.5 Press Button Description 6  \n2.6 Contrast Adjustment 7  \n2.7 Fixed Test Settings 7  \n2.8 Battery Low Message 8  \n2.9 Auto Power Down 8  \n2.10 Inadvertent Connection of Mains 8  \nSupply Voltage  \n3 PERFORMING APPLIANCE & LEAD TESTS  \n3.1 Preliminary Checks and Set Up 9  \n3.2 IEC Lead Test 10  \n3.3 Class I Test 11  \n3.4 Class II Test 13  \n3.5 Extension Lead Testing 14  \n3.6 Fuse Check Failure 16  \n3.7 Earth Continuity/Insulation Failure 17  \n4 MAINTENANCE  \n4.1 Fitting Batteries 18  \n4.2 Calibration 18  \n4.3 Cleaning 19  \n4.4 Repair & Service 19  \n4.5 Storage Conditions 19  \n5 WARRANTY 20  \nTECHNICAL SPECIFICATION  \n1. INTRODUCTION  \n1.1 Inspection  \nExamine the shipping carton for any sign of damage. Inspect the unit and any accessories for damage. If there is any damage then consult your distributor.  \nUnpack the HPAT400 and check that you have the following accessories:  \nInstructions  \nTest Probe with crocodile clip (TL67)  \n6 x Alkaline AA batteries IEC Adaptor Lead (Ex332) Zip carry case  \nInspect the unit and its accessories for any damage. If any item is missing or there is damage to any item, consult your distributor immediately.  \nRefer to section 4.1 for installation of batteries.  \n1.2 Description  \nThe battery powered HPAT400 HANDYPAT is a Portable Appliance Tester with the following features:  \nInsulation Test  \nInsulation Test at 500V.  \nAutomatic Test Sequence for Fixed Pass Levels  \nA connection diagram is shown in this handbook and on the label on the unit. When the test type is selected, the HPAT400 will run automatically through the test sequence without any further user interaction unless a failure is encountered. Pass or Fail outcome is displayed only.  \nDefault pass level on Class I.  \n≤0.20 Ω = PASS  \nIEC Lead Test  \nThe HPAT400 can also be used to check IEC leads and extension leads for earth continuity, insulation, and correct polarity,(Martindale Ex332 IEC lead required for extension lead testing) .  \nThe HPAT400 will perform the follo","cbCaikfCgGjWeg4j","https://ap.wps.com/l/cbCaikfCgGjWeg4j","pdf",1177708,28,"English","# 1 Introduction\n## 1.1 Unpacking and Inspection\n## 1.2 Description & Overview\n# 2 General Operation & Functions\n## 2.1 Precautions\n## 2.2 Power On/Off\n## 2.3 Display Indicators\n## 2.4 Connector Descriptions\n## 2.5 Press Button Description\n## 2.6 Contrast Adjustment\n## 2.7 Fixed Test Settings\n## 2.8 Battery Low Message\n## 2.9 Auto Power Down\n## 2.10 Inadvertent Connection of Mains\n# 3 Performing Appliance & Lead Tests\n## 3.1 Preliminary Checks and Set Up\n## 3.2 IEC Lead Test\n## 3.3 Class I Test\n## 3.4 Class II Test\n## 3.5 Extension Lead Testing\n## 3.6 Fuse Check Failure\n## 3.7 Earth Continuity/Insulation Failure\n# 4 Maintenance\n## 4.1 Fitting Batteries\n## 4.2 Calibration\n## 4.3 Cleaning\n## 4.4 Repair & Service\n## 4.5 Storage Conditions\n# 5 Warranty\n# Technical Specification","[{\"question\":\"What must be checked before using the HPAT400 HANDYPAT?\",\"answer\":\"Before use, inspect the unit for cracks or other damage and ensure it is free from dust, grease, and moisture. Also check associated leads and accessories, and do not use the unit if damaged.\"},{\"question\":\"What safety precautions are required during electrical testing?\",\"answer\":\"Do not touch the appliance being tested or the test probe tip while the HPAT400 is performing an electrical test. Where possible, use the provided crocodile clip to attach the probe to the appliance.\"},{\"question\":\"How should the HPAT400 be powered on and powered off?\",\"answer\":\"To power on, hold down the green power button for at least 1 second and proceed to the SELECT TEST screen. To power off, again hold down the green power button for at least 1 second.\"}]","HPAT400 HANDYPAT - InstructIon Manual - GENERAL SAFETY INFORMATION | PDF",1790745575,71]