[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-640629-105":59,"doc-detail-640629-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","hp-5973-mass-selective-detector-hardware-installation-manual","HP 5973 Mass Selective Detector - Hardware Installation Manual","","Hardware installation manual for the Hewlett-Packard HP 5973 Mass Selective Detector (MSD). Provides safety class and electrical safety warnings, including requirements for protective earth connection, correct fuse selection, and restrictions on opening/servicing the instrument while powered. Covers instrument identification via serial numbers, manual conventions for cautions/warnings, and installation scope: inspecting shipped materials, installing the GC and MSD, plumbing the methane line for CI flow modules, installing ChemStation, integrating systems, verifying EI/CI performance, and customer familiarization.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/hp-5973-mass-selective-detector-hardware-installation-manual/640629/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/hp-5973-mass-selective-detector-hardware-installation-manual/640629.png","ImageObject",300,407,{"name":92,"@type":93},"Rainbow Cat","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-27","2026-10-22",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the purpose of this manual for the HP 5973 MSD system?","Question",{"text":112,"@type":113},"It provides installation instructions for the HP 5973 Mass Selective Detector (MSD) system. Installation must be performed by a Hewlett-Packard service representative.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How is the HP 5973 MSD instrument identified?",{"text":117,"@type":113},"Each HP 5973 MSD is identified by a unique 10-character serial number. The serial number is on a label near the lower left side near the front of the instrument (and may be posted on the flow module for CI upgrades).",{"name":119,"@type":110,"acceptedAnswer":120},"What key safety warnings apply when connecting the MSD to power?",{"text":121,"@type":113},"Connecting the MSD to a power source without a protective earth contact creates a shock hazard and can damage the instrument. The document also warns to use only the correct fuse type/current rating and to avoid adjustments, maintenance, or repair of the opened instrument while it is connected to power unless performed by trained persons.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},640629,1792865133,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},962090769181,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","H􀃢  \nHP 5973  \nMass Selective Detector  \nHardware Installation Manual  \n© Copyright 1998  \nHewlett-Packard Company  \nAll Rights Reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws.  \nMicrosoft® and Windows NT® are U.S. registered trademarks of Microsoft Corporation.  \nDocument History Publication number G1099-90006  \nFirst edition, 2/98  \nPrinted in USA  \nWarranty The information contained in this document is subject to change without notice.  \nHewlett-Packard makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness fora particular purpose.  \nHewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material.  \nHewlett-Packard assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Hewlett-Packard.  \nNoise Declaration Deutsch  \nLpA \u003C\u003C 70 dB am Arbeitsplatz normaler Betrieb nach EN 27779:1991  \nEnglish  \nLpA \u003C\u003C 70 dB operator position normal operation per ISO 7779:1988  \nInstrument Identification  \nEach HP 5973 MSD is identified by a unique 10-character serial number. This serial number is located on a label on the lower left side near the front of the instrument. On CI upgrades, a serial number is posted on the flow module.  \nWhen corresponding with Hewlett-Packard about your instrument, be sure to include the model number and both full 10-character serial numbers.  \nManual Conventions Cautions  \nCautions call attention to procedures which, if not correctly performed or adhered to, could result in damage to the instrument.  \nWarnings  \nWarnings call attention to procedures which, if not correctly performed or adhered to, could result in personal injury.  \nPart Numbers  \nIn this manual, HewlettPackard part numbers are generally listed in parentheses after the name of the part or in tables in the Parts chapter. Most Hewlett-Packard part numbers are either four-digitby-four-digit (1234-1234) numbers or five-digit-by-fivedigit (12345-12345) numbers.  \nA few tools and supplies listed have no part numbers and are not available from Hewlett  \nPackard. Most of these can be obtained from laboratory supply companies.  \nSafety Information Safety Symbols The following symbols may be posted on HP instruments:  \n;  \n=  \n+  \n3  \nRefer to operating instructions  \nIndicates hazardous voltage  \nIndicates hot surface  \nIndicates earth (ground) terminal  \nSafety Information Safety class  \nThe HP 5973 Mass Selective Detector (MSD) is a Safety Class I instrument and has been designed and tested in accordance with IEC Publication 1010-1 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use.  \nWARNING  \nConnecting an MSD to a power source which is not equipped with a protective earth contact creates a shock hazard for the operator and can damage the instrument. Likewise, interrupting the protective conductor inside or outside the MSD or disconnecting the protective earth terminal creates a shock hazard for the operator and can damage the instrument.  \nWARNING  \nMake sure that only fuses with the required current rating and of the specified type are used for replacement. The use of incorrect or makeshift fuses or the short-circuiting of fuse holders creates a shock hazard for the operator and can damage the instrument.  \nWARNING Any adjustment, maintenance or repair of the opened instrument while it is connected to a power source should be avoided if possible and, if required, should be carried out only by trained persons who are aware of the hazards involved.  \nSafety Information continued on the inside of the back cover.  \nContents  \nChapter 1 General Information  \nIntroduction, 6  \nCustomer responsibilities, 8  \nSite requirements, 9  \nSpace requirements, 9  \nTelephone, 9  \nEnviro","cbCaiu8GfXbW3tcc","https://ap.wps.com/l/cbCaiu8GfXbW3tcc","pdf",612189,46,"English","# Chapter 1 General Information\n## Introduction\n## Customer responsibilities\n## Site requirements\n## Space requirements\n## Telephone\n## Environmental requirements\n## Power requirements\n## Gases\n## Other documentation\n# Chapter 2 Installation\n## Installation\n## Inspecting the shipped materials\n## Installing the GC\n## Installing the MSD\n## Plumbing the methane line to the CI MSD flow module\n## Installing the MSD ChemStation\n## Integrating the GC, MSD, and ChemStation\n## Verifying EI system performance\n## Switching from EI to CI operating mode\n## Verifying CI performance\n## Familiarizing the customer\n# Chapter 3 Checklists\n## Installation checklist\n## Customer familiarization checklist","[{\"question\":\"What is the purpose of this manual for the HP 5973 MSD system?\",\"answer\":\"It provides installation instructions for the HP 5973 Mass Selective Detector (MSD) system. Installation must be performed by a Hewlett-Packard service representative.\"},{\"question\":\"How is the HP 5973 MSD instrument identified?\",\"answer\":\"Each HP 5973 MSD is identified by a unique 10-character serial number. The serial number is on a label near the lower left side near the front of the instrument (and may be posted on the flow module for CI upgrades).\"},{\"question\":\"What key safety warnings apply when connecting the MSD to power?\",\"answer\":\"Connecting the MSD to a power source without a protective earth contact creates a shock hazard and can damage the instrument. The document also warns to use only the correct fuse type/current rating and to avoid adjustments, maintenance, or repair of the opened instrument while it is connected to power unless performed by trained persons.\"}]","HP 5973 Mass Selective Detector - Hardware Installation Manual | PDF",1792710087,116]