[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-396224-105":59,"doc-detail-396224-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","hospital-staff-change-room-design-layout","Hospital Staff Change Room - Design Layout","","This document provides a detailed architectural layout and elevation design for a hospital staff change room facility. The plan includes specific dimensions and locations for essential amenities such as lockers, a toilet (WC), a vanity unit with mirror, a shower area with a waterproof seat, and curtain partitions. It also outlines utility requirements including soap and paper towel dispensers, coat hooks, and lighting switches. The design adheres to standardized hospital and day procedure centre guidelines, featuring vinyl flooring and specific room access controls via a secure corridor entry. This technical drawing is intended for facility planning and construction guidance within a clinical environment, ensuring accessibility and functional efficiency for staff use.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/hospital-staff-change-room-design-layout/396224/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/hospital-staff-change-room-design-layout/396224.png","ImageObject",300,407,{"name":92,"@type":93},"Damian","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04","2026-09-26",true,{"@type":102,"interactionType":103,"userInteractionCount":39},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the primary amenities included in the staff change room?","Question",{"text":112,"@type":113},"The facility includes group lockers, a toilet (WC), a shower with a waterproof seat, a laminate vanity top with a splashback, and a full-length mirror.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What is the flooring material specified for the room?",{"text":117,"@type":113},"The room is designed with vinyl flooring, including vinyl coved skirting.",{"name":119,"@type":110,"acceptedAnswer":120},"How is access to the room controlled?",{"text":121,"@type":113},"The entrance from the hospital corridor is secured with card or keypad access for controlled entry.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},396224,1790760199,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":39,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":81,"preview_page_count":4},137451208677,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Change -Staff(Male/Female)  \nCOHCOAT HOOKDISPENSER -SOAPDISPENSER -SOAP ANTISEPTICDPTDISPENSER -PAPER TOWELDTPDISPENSER -TOILET PAPERFLOOR WASTE  \nGENERAL PURPOSE OUTLET-DOUBLEpLIGHT SWITCHOBSERVATION PANELSKIVINYL COVED SKIRTING,STANDARDSOILED LINEN TROLLEY  \n# PLAN\n\n2700  \n# ELEVATION 1\n\nELEVATION 2  \n## GROUP 3\n\nGROUP 3  \n2700  \n2100  \n# ELEVATION 4\n\nELEVATION 3  \nELEVATION 5  \n\n| Date  \u003Cbr>Date  \u003Cbr>Rev Revision Description  \u003Cbr>Rev Revision Description  \u003Cbr>Date  \u003Cbr>Rev Revision Description   |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1   | FIRST ISSUE   | 16.9.04   |  |  |  |  |  |  |  |  |  |\n| 2   | DRAWING REVISED   | 25.10.04   |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |\n| HEALTH PROJECTS INTERNATIONAL(c)  \u003Cbr>Ground Floor,Suite 1,68 Alfred Street,Milsons Point NSW 2061  \u003Cbr>Ph:(02)94604199 ww.hpi.net.au ACN:066856595   |  |  | The Department of Human Services,Victoria  \u003Cbr>Design guidelines for hospitals and day procedure centres  \u003Cbr>The Place To Be   |  |  |  | Sheet  \u003Cbr>Scale  \u003Cbr>Checked Date  \u003Cbr>Drawn   |  |  |  |  |\n|  |  |  |  |  |  |  | CC   | DB   | 25.10.04   | 1:50 in A3   | 1 of 1   |\n|  |  |  |  |  |  |  | CAD File  \u003Cbr>CHST   |  | Drawing No.  \u003Cbr>CHST   |  | lssue  \u003Cbr>2   |","cbCair60i6Jb9UJX","https://ap.wps.com/l/cbCair60i6Jb9UJX","pdf",191453,"English","# Floor Plan\n## Layout Overview\n## Amenity Placement\n# Elevation Details\n## Shower and Partition Area\n## Storage and Vanity Units","[{\"question\":\"What are the primary amenities included in the staff change room?\",\"answer\":\"The facility includes group lockers, a toilet (WC), a shower with a waterproof seat, a laminate vanity top with a splashback, and a full-length mirror.\"},{\"question\":\"What is the flooring material specified for the room?\",\"answer\":\"The room is designed with vinyl flooring, including vinyl coved skirting.\"},{\"question\":\"How is access to the room controlled?\",\"answer\":\"The entrance from the hospital corridor is secured with card or keypad access for controlled entry.\"}]","Hospital Staff Change Room - Design Layout | PDF",1790437640]