[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-231834-105":59,"doc-detail-231834-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","horizontal-air-delivery-models-dimensions-and-performance-tables","HORIZONTAL AIR DELIVERY MODELS - Dimensions and Performance Tables","","Catalog-style technical reference for Steam/Hot Water unit heaters with horizontal and vertical air delivery configurations. Provides mounting hole sizes and connection details, including top/bottom and side connection variants, plus casing and electrical-junction-box features. Includes dimension models HSB/HC, performance data for HC (60°F entering air) covering steam and hot-water heat inputs, flow/throw and mounting heights, and low-outlet temperature options. Also supplies vertical delivery model V/VN size tables with inlet/outlet connection dimensions.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/horizontal-air-delivery-models-dimensions-and-performance-tables/231834/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/horizontal-air-delivery-models-dimensions-and-performance-tables/231834.png","ImageObject",300,407,{"name":92,"@type":93},"Connor ","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-16","2026-09-10",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What mounting hole sizes and thread types are listed for HSB/HC horizontal air delivery models?","Question",{"text":113,"@type":114},"Mounting holes are given in two ranges: 18-86 with 3/8\"-16 tap, and 108-340 with 1/2\"-13 tap.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What performance data does the document provide for Model HC at 60°F entering air temperature?",{"text":118,"@type":114},"It lists steam and hot water inputs with resulting heat transfer (Btu/Hr), air/heat flow, motor and outlet temperatures, CFM, and maximum throw with corresponding mounting heights.",{"name":120,"@type":111,"acceptedAnswer":121},"How do the vertical air delivery models (V/VN) present specifications?",{"text":122,"@type":114},"They provide dimension tables by model number, including overall dimensions in inches, fan diameter, male connection NPT sizes, and approximate shipping weight.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},231834,1789067411,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":19,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":130,"read_time":52},687207022233,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","STeaM/hoT waTer UniT heaTerS  \nhorizonTal delivery Side connecTionS  \nverTical delivery  \n1-151.14 • JuLY, 2013  \nhorizonTal delivery ToP and BoTToM connecTionS  \nPower-ThrowTM  \nhorizonTal high-velociTy delivery  \nHORIZONTAL AIR DELIVERY MODELS  \nDimensions-Models HSB/HC  \n\n| Mounting Holes:\u003Cbr>Sizes 18-86, 3/8\"-16 Tap\u003Cbr>Sizes 108-340,1/2\"-13 Tap\u003Cbr>➀ Top/Bottom Connections (HSB only)\u003Cbr>➁ Side Connections (HC only) |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n| Model Size |  |  |  |  |  |  |  |\n|  | HSB |  | HC |  | C | D ➂ | Approx.\u003Cbr>Weight (lbs) |\n|  | A | B | A | B |  |  |  |\n| 18 & 24 | 12.38 | 13.00 | 11.50 | 13.00 | 6.00 | 5.00 | 16 & 20 |\n| 33 & 47 | 16.38 | 17.50 | 15.00 | 17.50 | 8.75 | 6.00 | 34 & 36 |\n| 63 & 86 | 20.44 | 21.50 | 18.50 | 21.50 | 8.75 | 7.75 | 48 & 52 |\n| 108 & 121 | 24.44 | 25.50 | 22.50 | 25.50 | 9.50 | 6.75 | 74 & 76 |\n| 165 | 30.50 | 30.50 | 26.50 | 29.50 | 9.25 | 8.50 | 92 |\n| 193 | 30.50 | 30.50 | 30.50 | 32.50 | 9.25 | 8.50 | 98 |\n| 258 & 290 | 38.50 | 38.50 | 38.50 | 38.50 | 12.50 | 10.00 | 162 & 168 |\n| 340 | 38.50 | 44.50 | 38.50 | 44.50 | 12.50 | 10.00 | 176 |\n\n➂ Dimensions shown apply to standard 115V/1ph motor (Power Code 01) .  \nHSB and HC models feature the following:  \n• Squared off corners for a clean, smooth appearance.  \n• HSB models have top and bottom supply and return steel connections.  \n• HC models have a copper tube and copper coil connections located on the side for low clearance applications.  \n• A two piece casing for quick access to coil.  \n• An electric junction box for easy electrical connections.  \n• Baked on gray-green, electrostatically applied polyester powdercoat, environmentally friendly paint.  \n• Motors are totally enclosed with thermal overload protection.  \n• Low outlet temperature models for higher steam pressures or dirty atmospheres.  \n• Listed by the Canadian Standards Association and CRN registered heat exchanger.  \nModel HC  \nPerformance Data (60°F Entering Air Temperature)  \n\n| Model Number | Standard Models\u003Cbr>Steam Hot Water\u003Cbr>(2\\# Steam) (200°F In, 180°F Out)\u003Cbr>Heat\u003Cbr>Final Final Max. Throw @\u003Cbr>➂ Air Water Air Mtg. Max. Mtg.\u003Cbr>Motor Temp. Flow Temp. Height Height\u003Cbr>HP Btu/Hr (°F) Btu/Hr (GPM) (°F) CFM (Ft) (Ft) |  |  |  |  |  |  |  |  | Low-Outlet Temperature Models\u003Cbr>Steam\u003Cbr> (2\\# Steam) \u003Cbr>Heat\u003Cbr>Final Max. Throw @\u003Cbr>Air Mtg. Max. Mtg.\u003Cbr>Temp. Height Height\u003Cbr>Model Number Btu/Hr CFM (°F) (Ft) (Ft) |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| HSB/HC 18 | 1/60 | 18,000 | 107 | 12,560 | 1.3 | 94 | 340 | 9 | 18 | HSB/HC 18L | 15,900 | 364 | 100 | 9 | 20 |\n| HSB/HC 24 | 1/25 | 24,000 | 119 | 16,250 | 1.7 | 100 | 370 | 10 | 19 | HSB/HC 24L | 19,300 | 435 | 100 | 11 | 21 |\n| HSB/HC 33 | 1/25 | 33,000 | 108 | 21,680 | 2.3 | 91 | 630 | 11 | 22 | HSB/HC 33L | 29,500 | 695 | 99 | 12 | 24 |\n| HSB/HC 47 | 1/12 | 47,000 | 119 | 30,940 | 3.2 | 98 | 730 | 13 | 30 | HSB/HC 47L | 32,000 | 855 | 94 | 14 | 32 |\n| HSB/HC 63 | 1/12 | 63,000 | 111 | 45,580 | 4.7 | 97 | 1120 | 15 | 31 | HSB/HC 63L | 52,500 | 1170 | 101 | 16 | 33 |\n| HSB/HC 86 | 1/8 | 86,000 | 118 | 60,210 | 6.3 | 101 | 1340 | 16 | 33 | HSB/HC 86L | 61,500 | 1510 | 97 | 17 | 36 |\n| HSB/HC 108 | 1/8 | 108,000 | 109 | 83,740 | 8.7 | 98 | 2010 | 18 | 33 | HSB/HC 108L | 86,500 | 2150 | 97 | 19 | 36 |\n| HSB/HC 121 | 1/5 | 121,000 | 122 | 93,000 | 9.7 | 108 | 1775 | 17 | 27 | HSB/HC 121L | 88,000 | 2070 | 98 | 18 | 29 |\n| HSB/HC 165 | 1/3 | 165,000 | 106 | 130,950 | 13.6 | 97 | 3240 | 20 | 43 | HSB/HC 165L | 143,000 | 3480 | 97 | 21 | 45 |\n| HSB/HC 193 | 1/3 | 193,000 | 121 | 143,000 | 14.9 | 105 | 2900 | 19 | 40 | — | — | — | — | — |  |\n| HSB/HC 258 | 1/2 | 258,000 | 111 | 201,950 | 21 | 100 | 4560 | 20 | 47 | HSB/HC 258L | 190,000 | 4655 | 98 | 22 | 51 |\n| HSB/HC 290 | 1/2 | 290,000 | 117 | 228,620 | 23.8 | 105 | 4590 | 21 | 49 | HSB/HC 290L | 207,000 | 5040 | 94 | 23 | 53 |\n| HSB/HC 340 | 1/2 |","cbCaimBPOIccjLr9","https://ap.wps.com/l/cbCaimBPOIccjLr9","pdf",1392306,"English","# HORIZONTAL AIR DELIVERY MODELS\n## Power-ThrowTM and delivery connection types\n## Dimensions-Models HSB/HC\n## Mounting holes and connections\n## Model HC Performance Data (60°F entering air temperature)\n## Low-Outlet Temperature Models\n# VERTICAL AIR DELIVERY MODELS\n## Model V/VN dimensions and connection sizes","[{\"question\":\"What mounting hole sizes and thread types are listed for HSB/HC horizontal air delivery models?\",\"answer\":\"Mounting holes are given in two ranges: 18-86 with 3/8\\\"-16 tap, and 108-340 with 1/2\\\"-13 tap.\"},{\"question\":\"What performance data does the document provide for Model HC at 60°F entering air temperature?\",\"answer\":\"It lists steam and hot water inputs with resulting heat transfer (Btu/Hr), air/heat flow, motor and outlet temperatures, CFM, and maximum throw with corresponding mounting heights.\"},{\"question\":\"How do the vertical air delivery models (V/VN) present specifications?\",\"answer\":\"They provide dimension tables by model number, including overall dimensions in inches, fan diameter, male connection NPT sizes, and approximate shipping weight.\"}]","HORIZONTAL AIR DELIVERY MODELS - Dimensions and Performance Tables | PDF"]