[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-674451-105":59,"doc-detail-674451-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","hm1734-wm-2hr-installation-instructions-point-io-strain-gage-input-module","HM1734-WM-2HR - Installation Instructions - POINT I/O Strain Gage Input Module","","HM1734-WM-2HR installation instructions for the POINT I/O Strain Gage Input Module, including mounting, mechanical keying, wiring base assembly, removable terminal block handling, locking mechanism steps, DIN rail setup, and module wiring diagram references. Guidance covers grounding and electrostatic discharge precautions, explosion hazard warnings for hazardous environments, and requirements for enclosures, pollution degree, and overvoltage category. Users are instructed to ensure applications meet safety and performance requirements and that example illustrations are not a substitute for site-specific design.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/hm1734-wm-2hr-installation-instructions-point-io-strain-gage-input-module/674451/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/hm1734-wm-2hr-installation-instructions-point-io-strain-gage-input-module/674451.png","ImageObject",300,407,{"name":92,"@type":93},"McGucket","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04",true,{"@type":101,"interactionType":102,"userInteractionCount":4},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What are the key installation steps for HM1734-WM-2HR?","Question",{"text":111,"@type":112},"The manual describes mounting, mechanical keying, wiring base assembly setup, removable terminal block (RTB) use, module locking, and DIN rail mounting with the appropriate locking screw and side pieces. It also references the module wiring diagram for connection planning.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What enclosure and environmental conditions does the module require?",{"text":116,"@type":112},"Use the equipment in a Pollution Degree 2 industrial environment and overvoltage Category II applications, at altitudes up to 2000 meters without derating. Mount it as “open type” equipment inside an enclosure designed to prevent access to live parts using tools only.",{"name":118,"@type":109,"acceptedAnswer":119},"How should grounding and electrostatic discharge (ESD) be handled?",{"text":120,"@type":112},"POINT I/O is grounded through the DIN rail to chassis ground; use zinc plated, yellow chromated steel DIN rail to ensure proper grounding. The equipment is sensitive to electrostatic discharge, so discharge static by touching a grounded object and follow safe handling guidance.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},674451,1793762939,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":4,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":138,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":128,"read_time":143},1236954412713,"https://us-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","Helm Instrument Company, Inc.  \n361 West Dussel Drive Maumee, Ohio 43537 USA 419/ 893-4356  \nFax: 419/ 893-1371  \n[www.helminstrument.com](www.helminstrument.com)  \n4  \n5  \n6  \nInstallation Instructions HM1734-WM-2HR  \nPOINT I/O Strain Gage Input Module 2/11/2019  \nDescription Description  \n1 Mounting Base1 6 RTB Removal Handle  \n2 Mechanical Keying (orange) 7 Removable Terminal Block (RTB)1  \n3 Module Wiring Diagram 8 DIN Rail Locking Screw (orange)  \n4 Module Locking Mechanism 9 Slide-in Writable Label  \n5 Insertable I/O Module 10 Interlocking Side Pieces  \n1 Wiring Base Assembly consists of item 1) mounting base, 1734-MB and item 7) removable terminal block, 1734-RT or-RTS.  \nPOINT I/O is a trademark of Rockwell Automation DeviceNet is a trademark of ODVA, Inc.  \nFebruary, 2019  \nThis Series C product can be used with DeviceNet and PROFIBUS adapters. It can be used with Ethernet/IP and Ethernet adapters using RSLogix 5000, version 11 (or higher) software.  \nImportant User Information  \nBecause of the variety of uses for the products described in this publication, those responsible for the application and use of these products must satisfy themselves that all necessary steps have been taken to assure that each application and use meet all performance and safety requirements, including any applicable laws, regulations, codes and standards. In no event will Allen-Bradley be responsible or liable for indirect or consequential damage resulting from the use or application of these products.  \nAny illustrations, charts, sample programs, and layout examples shown in this publication are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Allen-Bradley does not assume responsibility or liability (to include intellectual property liability) for actual use based upon the examples shown in this publication.  \nAllen-Bradley publication SGI-1.1, Safe yt Guidelines for the Application, Installation and Maintenance of Solid-State Control (available from your local Allen-Bradley office), describes some important differences between  \nsolid-state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication.  \nReproduction of the contents of this copyrighted publication, in whole or part, without written permission of Rockwell Automation, is prohibited. Throughout this publication, notes may be used to make you aware of safety considerations. The following annotations and their accompanying statements help you to identify a potential hazard, avoid a potential hazard, and recognize the consequences of a potential hazard.  \n\n| \u003Cbr>WARNING\u003Cbr>! | Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. |\n| --- | --- |\n\n\n| ATTENTION | Identifies information about practices or\u003Cbr>circumstances that can lead to personal injury or |\n| --- | --- |\n| ! | death, property damage, or economic loss. |\n| \u003Cbr>IMPORTANT | Identifies information that is critical for successful application and understanding of the product. |\n\n-  \nATTENTION  \n!  \nEnvironment and Enclosure  \nThis equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC publication 60664-1), at altitudes up to 2000 meters without derating.  \nThis equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR Publication 11. Without appropriate precautions, there may be potential difficulties ensuring electromagnetic compatibility in other environments due to conducted as well as radiated disturbance.  \nThis equipment is supplied as \"open type\" equipment. It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately ","cbCaincb6aBV6wXH","https://ap.wps.com/l/cbCaincb6aBV6wXH","pdf",726857,23,"English","# Installation Instructions HM1734-WM-2HR\n## POINT I/O Strain Gage Input Module\n## Environment and Enclosure\n## Explosion Hazard and ESD Precautions","[{\"question\":\"What are the key installation steps for HM1734-WM-2HR?\",\"answer\":\"The manual describes mounting, mechanical keying, wiring base assembly setup, removable terminal block (RTB) use, module locking, and DIN rail mounting with the appropriate locking screw and side pieces. It also references the module wiring diagram for connection planning.\"},{\"question\":\"What enclosure and environmental conditions does the module require?\",\"answer\":\"Use the equipment in a Pollution Degree 2 industrial environment and overvoltage Category II applications, at altitudes up to 2000 meters without derating. Mount it as “open type” equipment inside an enclosure designed to prevent access to live parts using tools only.\"},{\"question\":\"How should grounding and electrostatic discharge (ESD) be handled?\",\"answer\":\"POINT I/O is grounded through the DIN rail to chassis ground; use zinc plated, yellow chromated steel DIN rail to ensure proper grounding. The equipment is sensitive to electrostatic discharge, so discharge static by touching a grounded object and follow safe handling guidance.\"}]","HM1734-WM-2HR - Installation Instructions - POINT I/O Strain Gage Input Module | PDF",58]