[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-671270-105":59,"doc-detail-671270-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","hit-re-500-v3-injection-mortar-rebar-design-and-bond-strength-data","HIT-RE 500 V3 injection mortar - Rebar design and bond strength data","","HIT-RE 500 V3 injection mortar specification for post-installed and rebar design according to EN 1992-1, including rebar element selection and performance benefits. Provides installation and base-material suitability for concrete classes, load conditions (static/seismic/fire), temperature curing limits down to -5°C, and SafeSet borehole preparation. Details European Technical Assessment and certificates (ETA-16/0142), plus bond design parameters, pullout bond strength ranges, and adjustment rules for poor bond conditions, supported by drilling method tables.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/hit-re-500-v3-injection-mortar-rebar-design-and-bond-strength-data/671270/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/hit-re-500-v3-injection-mortar-rebar-design-and-bond-strength-data/671270.png","ImageObject",300,407,{"name":92,"@type":93},"Franzy","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-03","2026-11-01",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What concrete classes and environments is HIT-RE 500 V3 suitable for?","Question",{"text":112,"@type":113},"It is suitable for concrete C 12/15 to C 50/60, including dry and water-saturated concrete, with non-corrosive behavior for rebar elements. It also supports curing down to -5°C and provides long working time at elevated temperatures.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does SafeSet technology simplify borehole preparation?",{"text":117,"@type":113},"SafeSet uses a simplified method of borehole preparation with either a Hilti hollow drill bit for hammer drilling or a Roughening tool for diamond cored applications.",{"name":119,"@type":110,"acceptedAnswer":120},"How are bond strength values adjusted for poor bond conditions?",{"text":121,"@type":113},"For poor bond conditions, the document specifies multiplying the values by 0.7.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},671270,1793575495,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},2336478945519,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","HIT-RE 500 V3 injection mortar  \nRebar design (EN 1992-1) / Rebar elements / Concrete  \nInjection mortar system Benefits  \nFoil pack: HIT-RE 500 V3 (available in 330, 500 and 1400 ml cartridges)  \nRebar B500 B (8- 40)  \n- SafeSet technology: Simplified method of borehole preparation using either Hilti hollow drill bit for hammer drilling or Roughening tool for diamond cored applications  \n- Suitable for concrete C 12/15 to C 50/60  \n- High loading capacity  \n- Suitable for dry and water saturated concrete  \n- Non-corrosive to rebar elements  \n- Long working time at elevated temperatures  \n- Cures down to-5°C  \n- Odourless epoxy  \n- Fire time exposure up to 4h  \nBase material Load conditions  \nConcrete Concrete Dry concrete Wet concrete Static/ Seismic, Fire  \n(non- (cracked) quasi-static ETA-C1 resistance  \ncracked)  \n Installation conditions  Other informations   \nHammer drilling  \nDiamond coring  \nEuropean Technical Assessment  \nCE  \nconformity  \nPROFIS Rebar design Software  \nApprovals / certificates  \n\n| Description | Authority / Laboratory | No. / date of issue |\n| --- | --- | --- |\n| European technical assessment a) | CSTB, Marne la Vallée | ETA-16/0142 / 2018-07-04 |\n| Fire evaluation | CSTB, Marne la Vallée | MRF 1526054277/B |\n\nb) All data given in this section according to ETA-16/0142 issue 2018-07-04.  \nStatic and quasi-static loading  \nfbd [ N/mm2]  \nMaximum design bond strength according to Hit Rebar Method design  \nDesign bond strength   \naccording to EC2   \nExtension for post-installed rebars with large cover  \n~~ ~~ (product dependent)   \ncd/ [-]  \nEffective limit on bond stress for post-installed rebar using Hilti mortar systems and design bond strength values as provided by the EC2 .  \nStatic EC2 design, small concrete cover (see section 3.2.1)  \nDesign bond strength in N/mm2 according to ETA 16/0142 for good bond conditions  \n\n| All allowed hammer drilling methods |  |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Rebar-size | Concrete class |  |  |  |  |  |  |  |  |  |  |  |\n|  | C12/15 |  | C16/20 | C20/25 | C25/30 | C30/37 |  | C35/45 | C40/50 | C45/55 | C50/60 |  |\n| 8- 32 | 1,6 |  | 2,0 | 2,3 | 2,7 | 3,0 |  | 3,4 | 3,7 | 4,0 | 4,3 |  |\n| 36 | 1,6 |  | 1,9 | 2,2 | 2,6 | 2,9 |  | 3,2 | 3,5 | 3,8 | 4,1 |  |\n| 40 | 1,5 |  | 1,8 | 2,1 | 2,5 | 2,8 |  | 3,1 | 3,4 | 3,7 | 3,9 |  |\n| Diamond coring wet |  |  |  |  |  |  |  |  |  |  |  |  |\n| 8- 12 | 1,6 |  | 2,0 | 2,3 | 2,7 | 3,0 |  | 3,4 | 3,7 | 4,0 | 4,0 |  |\n| 14- 16 | 1,6 |  | 2,0 | 2,3 | 2,7 | 3,0 |  | 3,4 | 3,7 | 3,7 | 3,7 |  |\n| 20- 32 | 1,6 |  | 2,0 | 2,3 | 2,7 | 3,0 |  | 3,4 | 3,4 | 3,4 | 3,4 |  |\n| 36 | 1,6 |  | 2,0 | 2,2 | 2,6 | 2,9 |  | 3,2 | 3,2 | 3,2 | 3,2 |  |\n| 40 |  | 1,6 | 2,0 | 2,1 | 2,5 |  | 2,8 | 2,8 | 2,8 | 2,8 |  | 2,8 |\n\nFor poor bond conditions multiply the values by 0,7 .  \nChem ica l anchors Concrete  \nMechanical anchors  \nPlastic/Light duty metal anchors  \nInsulation anchors  \nChem ica l anchors Concrete  \nMechanical anchors  \nPlastic/Light duty metal anchors  \nInsulation anchors  \nStatic Hit Rebar design method, large concrete cover (see section 3.2.2)  \nPullout design bond strength [fbd,po RkMp] in N/mm² for good bond conditions  \n\n| Non-cracked concrete C20/25, all allowed drilling methods |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Temperature range\u003Cbr>Drilling method |  | Rebar-size |  |  |  |  |  |  |  |  |  |  |  |\n|  |  | 8 | 10 | 12 | 14 | 16 | 20 | 25 | 28 | 30 | 32 | 36 | 40 |\n| I: 40°C/24° C | Hammer drilled holes\u003Cbr>Hammer drilled holes\u003Cbr>with hollow drill bit\u003Cbr>Diamond cored holes\u003Cbr>with roughening tool\u003Cbr>Diamond cored holes\u003Cbr>Hammer drilled holes\u003Cbr>in water filled holes | 6,3 | 9,5 | 9,5 | 9,5 | 9,5 | 9,5 | 8,7 | 8,7 | 8,7 | 8,7 | 6,7 | 7,9 |\n|  |  | - | - | 9,5 | 9,5 | 9,5 | 9,5 | 8,7 | 8,7 | - | - | - | - |\n|  |  | - | - | - | 9,5 | 9,5 | 9,5 | 8,7 | 8,7 | - | ","cbCaib7Y6fY7Q27o","https://ap.wps.com/l/cbCaib7Y6fY7Q27o","pdf",1504154,17,"English","# Injection mortar system overview\n## Product benefits and suitability\n## SafeSet borehole preparation\n# Base materials and installation conditions\n## Load conditions\n## Drilling methods (hammer drilling, diamond coring)\n# European Technical Assessment and approvals\n## ETA and fire evaluation references\n# Rebar design and bond strength calculations\n## Maximum and effective bond strength\n## Pullout design bond strength\n## Poor bond adjustment factors\n# Design tables by concrete class and temperature\n## Static EC2 design tables\n## Large concrete cover design tables","[{\"question\":\"What concrete classes and environments is HIT-RE 500 V3 suitable for?\",\"answer\":\"It is suitable for concrete C 12/15 to C 50/60, including dry and water-saturated concrete, with non-corrosive behavior for rebar elements. It also supports curing down to -5°C and provides long working time at elevated temperatures.\"},{\"question\":\"How does SafeSet technology simplify borehole preparation?\",\"answer\":\"SafeSet uses a simplified method of borehole preparation with either a Hilti hollow drill bit for hammer drilling or a Roughening tool for diamond cored applications.\"},{\"question\":\"How are bond strength values adjusted for poor bond conditions?\",\"answer\":\"For poor bond conditions, the document specifies multiplying the values by 0.7.\"}]","HIT-RE 500 V3 injection mortar - Rebar design and bond strength data | PDF",43]