[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-670562-105":59,"doc-detail-670562-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","hit-hy-200-injection-mortar-technical-datasheet-update-aug-18","HIT-HY 200 - Injection Mortar - Technical Datasheet Update - Aug-18","","HIT-HY 200 injection mortar technical datasheet update (Aug-18) for anchor design in concrete using Hilti rod and sleeve systems. It outlines ETAG 001 anchor design elements with options for HIT-V/HIS-N/HIT-Z variants, including two mortar curing versions HY 200-R (slow cure) and HY 200-A (fast cure). The datasheet specifies SafeSet drilling and cleaning, application to cracked and non-cracked concrete C20/25 to C50/60, seismic category approvals, fire resistance and CE conformity, plus installation conditions and load information.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/hit-hy-200-injection-mortar-technical-datasheet-update-aug-18/670562/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/hit-hy-200-injection-mortar-technical-datasheet-update-aug-18/670562.png","ImageObject",300,407,{"name":92,"@type":93},"Stanford","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-03","2026-11-01",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the two mortar versions of HIT-HY 200 and when are they used?","Question",{"text":112,"@type":113},"HY 200-R is for slow cure applications, while HY 200-A is for fast cure applications.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What concrete types and strength classes are suitable for HIT-HY 200 injection mortar?",{"text":117,"@type":113},"It is suitable for non-cracked and cracked concrete C 20/25 to C 50/60.",{"name":119,"@type":110,"acceptedAnswer":120},"Which systems and rods are covered for seismic approvals, and what limitations apply?",{"text":121,"@type":113},"ETA approval is given for seismic performance category C1 and C2a). HIS-N internally threaded sleeves are not approved for seismic, and high corrosion resistant rods are available only for HIT-V (with additional mention for HIT-V and HIS-N depending on the rod).","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},670562,1793570039,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},2336477552062,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","HIT-HY 200  \nINJECTION MORTAR  \nTechnical Datasheet Update: Aug-18  \nHIT-HY 200 injection mortar  \nAnchor design (ETAG 001) / Rods&Sleeves / Concrete  \nInjection mortar system Benefits  \nHilti HIT-HY 200-A  \n500 ml foil pack (also available as 330 ml foil pack)  \nHilti HIT-HY 200-R  \n500 ml foil pack (also available as 330 ml foil pack)  \nAnchor rod: HIT-V  \nHIT-V-F  \nHIT-V-R  \nHIT-V-HCR (M8-M30)  \nInternally threaded sleeve:  \nHIS-N  \nHIS-RN (M8-M20)  \nAnchor rod: HIT-Z  \nHIT-Z-F  \nHIT-Z-R (M8-M20)  \n- SafeSet technology: drilling and borehole cleaning in one step with Hilti hollow drill bit  \n- Suitable for non-cracked and cracked concrete C 20/25 to C 50/60  \n- ETA Approved for seismic performance category C1, C2a)  \n- Maximum load performance in cracked concrete and noncracked concrete  \n- High corrosion / corrosion resistanceb)  \n- Small edge distance and anchor spacing possible  \n- Manual cleaning for borehole diameter up to 20mm and hef≤10d for non-cracked concrete only  \n- Two mortar versions: HY 200-R for slow cure applications and HY 200-A for fast cure applications  \na) HIS-N internally threaded sleeves not approved for Seismic.  \nb) High Corrosion resistant rods available only for HIT-V. Corrosion resistant rods available for HIT-V and HIS-N  \nBase material Installation conditions  \nConcrete (non-cracked)  \nConcrete (cracked)  \nHammer drilled holes  \nDiamond  \ndrilled holes c)  \nVariable embedment depth  \nSmall edge distance and spacing  \nLoad conditions Other information  \nStatic/ quasi-static  \nSeismic, ETA-C1, C2a)  \nFire resistance  \nEuropean Technical Assessment  \nCE conformity  \nHigh corrosion resistanceb)  \nPROFIS Anchor design Software  \na) HIS-N internally threaded sleeves not approved for Seismic category C2 .  \nb) High Corrosion resistant rods available only for HIT-V. Corrosion resistant rods available for HIT-V and HIS-N  \nc) Diamond drilling only covered for HIT-Z rods  \nApprovals / certificates  \n\n| Description | Authority / Laboratory | No. / date of issue |\n| --- | --- | --- |\n| European technical Assessment a) | DIBt, Berlin | ETA-11/0493/ 2017-07-28 (HY200 A) |\n| European technical Assessment a) | DIBt, Berlin | ETA-12/0006/ 2017-05-30 (HY200 A) |\n| European technical Assessment a) | DIBt, Berlin | ETA-12/0084/ 2017-07-28 (HY200 R) |\n| European technical Assessment a) | DIBt, Berlin | ETA-12/0028/ 2017-05-30 (HY200 R) |\n| Shockproof fastenings in civil defence installations | Federal Office for Civil Protection, Bern | BZS D 13-604 / 2013-12-31\u003Cbr>BZS D 13-603 / 2013-12-31 |\n| Fire test report | IBMB, Brunswick | 3501/676/13 / 2012-08-03 |\n\na) All data given in this section according to ETA-11/0493 , issue 2017-07-28 , ETA-12/0006 , issue 2017-05-30, ETA-12/0084, issue 2017-07- 28 and ETA-12/0028, issue 2017-05-30  \nStatic and quasi-static resistance (for a single anchor)  \nAll data in this section applies to:  \n- Correct setting (See setting instruction)  \n- No edge distance and spacing influence  \n- Steel failure  \n- Minimum base material thickness  \n-  One typical embedment depth, as specified in the table  \n-  One anchor material, as specified in the tables  \n- Concrete C 20/25, fck,cube = 25 N/mm²  \n- Temperature range I (min. base material temp. -40°C, max. long/short term base material temp.: +24°C/40°C)  \nFor hammer drilled holes, hammer drilled holes with Hilti hollow drill bit:  \nAnchorage depth 1)  \n\n| Anchor size | M8 | M10 | M12 | M16 | M20 | M24 | M27 | M30 |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| HIT-V |  |  |  |  |  |  |  |  |\n| Embedment depth [mm] | 80 | 90 | 110 | 125 | 170 | 210 | 240 | 270 |\n| Base material thickness [mm] | 110 | 120 | 140 | 161 | 234 | 266 | 300 | 340 |\n| HIS-N |  |  |  |  |  |  |  |  |\n| Embedment depth [mm] | 90 | 110 | 125 | 170 | 205 | - | - | - |\n| Base material thickness [mm] | 120 | 150 | 170 | 230 | 270 | - | - | - |\n| HIT-Z |  |  |  |  |  |  |  |  |\n| Effective anchorage depth2) hef =lHelix [mm] | 50 | 60 | 60 | 96 | 100 | - | - |","cbCaieZtaQ3EEk3z","https://ap.wps.com/l/cbCaieZtaQ3EEk3z","pdf",2365613,39,"English","# Anchor design and system overview\n## SafeSet technology and key benefits\n## Compatible base materials and installation conditions\n# Components and mortar variants\n## HIT-V rods and internally threaded sleeves\n## HIT-Z rods and diamond drilling coverage\n# Approvals, certificates and software\n## European Technical Assessment and test reports\n## PROFiS Anchor design software\n# Design data and resistances\n## Embedment depth and base material thickness tables\n## Static, quasi-static and seismic resistance\n## Mean ultimate resistance and characteristic resistance","[{\"question\":\"What are the two mortar versions of HIT-HY 200 and when are they used?\",\"answer\":\"HY 200-R is for slow cure applications, while HY 200-A is for fast cure applications.\"},{\"question\":\"What concrete types and strength classes are suitable for HIT-HY 200 injection mortar?\",\"answer\":\"It is suitable for non-cracked and cracked concrete C 20/25 to C 50/60.\"},{\"question\":\"Which systems and rods are covered for seismic approvals, and what limitations apply?\",\"answer\":\"ETA approval is given for seismic performance category C1 and C2a). HIS-N internally threaded sleeves are not approved for seismic, and high corrosion resistant rods are available only for HIT-V (with additional mention for HIT-V and HIS-N depending on the rod).\"}]","HIT-HY 200 - Injection Mortar - Technical Datasheet Update - Aug-18 | PDF",98]