[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-670563-105":59,"doc-detail-670563-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","hit-hy-200-a-v3-injection-mortar","HIT-HY 200-A V3 - Injection Mortar","","PRODUCT TECHNICAL DATASHEET for Hilti HIT-HY 200-A V3 and HIT-HY 200-R V3 injection mortars used with steel-to-concrete anchor systems. Specifies anchor designs per EN 1992-4 and EOTA TR 082/086, including anchor rods, internally threaded sleeves, and rebar. Highlights benefits such as faster installation, automatic borehole cleaning, accurate dosing, adaptive torque fastening, and suitability for uncracked/cracked concrete, seismic ETA-C1/C2, and fire/fatigue performance. Includes approvals with ETA numbers, application conditions, drilling/cleaning/set-up options, and dimension tables.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/hit-hy-200-a-v3-injection-mortar/670563/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/hit-hy-200-a-v3-injection-mortar/670563.png","ImageObject",300,407,{"name":92,"@type":93},"McQueen","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-03","2026-11-01",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What concrete conditions are HIT-HY 200-A V3 and HIT-HY 200-R V3 suitable for?","Question",{"text":112,"@type":113},"They are suitable for uncracked and cracked concrete C20/25 to C50/60, and also for dry and water-saturated concrete. The datasheet also covers fastening in SFRC.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which seismic and fire-related performance categories are referenced?",{"text":117,"@type":113},"The document states ETA for seismic performance category C1 and C2. It also provides data under fire exposure according to TR082 for threaded rod sizes M8 to M30.",{"name":119,"@type":110,"acceptedAnswer":120},"What installation advantages does the system claim?",{"text":121,"@type":113},"It emphasizes faster, simpler, safer, and more sustainable installation. It highlights automatic borehole cleaning with hollow drill bits, accurate dosing with HDE, and fast and safe torquing using the adaptive torque (AT) system.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},670563,1793570078,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},5909890329169,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","PRODUCT TECHNICAL DATASHEET  \nHIT-HY 200-A V3  \nHIT-HY 200-R V3 INJECTION MORTAR  \nSteel-to-concrete Update: Feb-26  \nHIT-HY 200-A V3 and HIT-HY 200-R V3 injection mortars Anchor design (EN 1992-4, EOTA TR 082 and TR 086) / Rods, Sleeves and Rebar / Concrete  \nInjection mortar system Benefits  \nHilti HIT-HY 200-A V3  \nHilti HIT-HY 200-R V3  \n500 ml foil pack (also available as 330 ml foil pack)  \nAnchor rod (M8-M30): HAS,  \nHAS HDG,  \nHAS A4,  \nHAS-U,  \nHAS-U HDG,  \nHAS-U A4 ,  \nHAS-U HCR  \nInternally threaded sleeve (M8-M20):  \nHIS-N  \nHIS-RN  \nAnchor rod (M8-M20): HIT-Z(-D TP)  \nHIT-Z-F  \nHIT-Z-R(-D TP)  \nAnchor rod (M12-M20): HAS-D  \nRebar (φ8- φ32)  \n- Makes installation steps faster, simpler-safer and more sustainable. Automatic borehole cleaning with hollow drill bits, accurate dosing with HDE and fast and safe torquing with the adaptive torque (AT) system.  \n- Suitable for uncracked and cracked concrete C20/25 to C50/60  \n- ETA for seismic performance category C1, C2  \n- Maximum load performance in cracked concrete and uncracked concrete  \n- High corrosion / corrosion resistance  \n- Small edge distance and anchor spacing possible  \n- Manual cleaning for borehole diameter up to 20mm and hef ≤ 10d for uncracked concrete only  \n- ETA data for 50 , 100 and 120 years working life  \n- ETA for fastening in SFRC  \n- Suitable for dry and water saturated concrete  \n- Data under fire exposure in accordance with TR082 for threaded rod size M8 to M30  \n- Anchorage in steel fibrereinforced concrete with HAS-D  \nApplication condition  \nBase material Load conditions  \nConcrete (uncracked)  \nConcrete (cracked)  \nConcrete (SFRC)  \nStatic/ quasi-static  \nSeismic ETA-C1, C2  \nFatigue Fire  \nresistance  \nDrilling, cleaning, setting Other information  \nHammer drilled holes  \nDiamond cored holes with  \nroughening  \nHollow Drill Bit drilled holes  \nWater saturated  \nWater-filled boreholes  \nImpact wrench with adaptative torque module  \nVariable embedment depth  \nLinked Approvals/Certificates and Instructions for use.  \nApprovals/certificates  \n\n| Approval no\u003Cbr>(steel elements) | Application / loading condition | Authority / Laboratory | Date of issue |\n| --- | --- | --- | --- |\n| ETA-19/0601\u003Cbr>(HAS, HIS-N, rebar) | Static and quasi-static / Seismic / Fire\u003Cbr>50 / 100 years | DIBt, Berlin | 08-09-2025 |\n| ETA-19/0632\u003Cbr>( HIT-Z) | Static and quasi-static / Seismic | DIBt, Berlin | 26-09-2024 |\n| ETA-18/0972\u003Cbr>( HAS-D) | Static and quasi-static | DIBt, Berlin | 26-09-2024 |\n| ETA-15/0296\u003Cbr>( HIT-Z-D-TP) | Static and quasi-static / Seismic | DIBt, Berlin | 18-07-2023 |\n| ETA-18/0978\u003Cbr>( HAS-D) | Static and quasi-static / Fatigue | DIBt, Berlin | 26-09-2024 |\n| ETA-19/0802\u003Cbr>( HIT-Z-D-TP) | Static and quasi-static / Fatigue | DIBt, Berlin | 18-09-2024 |\n| ETA-25/0584\u003Cbr>(HAS, HIS-N, rebar) | Static and quasi-static / Seismic / Fire\u003Cbr>120 years | DIBt, Berlin | 08-09-2025 |\n| ETA-25/0669\u003Cbr>(HAS, HIS-N, rebar) | SFRC (sizes M12-M24) Static and quasi-static / Seismic / Fire\u003Cbr>50 / 100 years | DIBt, Berlin | 07-01-2026 |\n\nApprovals/certificates for normal weight concrete with maximum steel fibre content of 80 kg/m3  \n\n| Approval no | Application / loading condition | Authority / Laboratory | Date of issue | Date of expiry |\n| --- | --- | --- | --- | --- |\n| Z-21.3-2155\u003Cbr>(HAS-D) | Fatigue applications in Steel Fibre Reinforced Concrete (SFRC) | DIBt, Berlin | 19-03-2024 | 19-03-2029 |\n\nThe instructions for use can be viewed using the link in the instructions for use table or the QR code/link in the Hilti webpage table  \nInstructions for use(IFU)  \n\n| Material |  |  |  |  |\n| --- | --- | --- | --- | --- |\n| Injection mortar | IFU HIT-HY 200-A V3 |  | IFU HIT-HY-200-R V3 |  |\n| Dispenser | IFU HDM | IFU HDE 500-22 |  | IFU HDE 500-A12 |\n\nLinks to Hilti Webpage  \n\n| Injection mortars / Dispenser / Accessories |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- |\n| HIT-HY 200-A V3 | HIT-HY 200-R V3 | HDE 500-22 | HDE 500-A12 | HDM 500 | Filling","cbCaipXcIDhWnEza","https://ap.wps.com/l/cbCaipXcIDhWnEza","pdf",2178585,23,"English","# Injection mortar system benefits\n## Application conditions and load scenarios\n## Approvals / certificates and ETA data\n## Instructions for use (IFU) and Hilti webpage links\n## Fasteners and mechanical properties (dimensions, materials)","[{\"question\":\"What concrete conditions are HIT-HY 200-A V3 and HIT-HY 200-R V3 suitable for?\",\"answer\":\"They are suitable for uncracked and cracked concrete C20/25 to C50/60, and also for dry and water-saturated concrete. The datasheet also covers fastening in SFRC.\"},{\"question\":\"Which seismic and fire-related performance categories are referenced?\",\"answer\":\"The document states ETA for seismic performance category C1 and C2. It also provides data under fire exposure according to TR082 for threaded rod sizes M8 to M30.\"},{\"question\":\"What installation advantages does the system claim?\",\"answer\":\"It emphasizes faster, simpler, safer, and more sustainable installation. It highlights automatic borehole cleaning with hollow drill bits, accurate dosing with HDE, and fast and safe torquing using the adaptive torque (AT) system.\"}]","HIT-HY 200-A V3 - Injection Mortar | PDF",58]