[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-463345-105":59,"doc-detail-463345-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","highly-sensitive-detection-of-anti-sars-cov-2-antibodies-in-human-serum-using-bloch-surface-wave-biosensor","Highly Sensitive Detection of Anti-SARS-CoV-2 Antibodies in Human Serum Using Bloch Surface Wave Biosensor","","Accurate and sensitive antibody detection is essential for advanced COVID-19 diagnostics and for monitoring SARS-CoV-2 immunity. This study introduces a highly sensitive approach to detect anti-SARS-CoV-2 antibodies in human serum using an integrated photonic sensing platform. The method relies on disposable one-dimensional photonic crystal biochips designed to support Bloch Surface Waves and uses a custom optical setup for dual-mode measurement. It enables label-free refractometry for binding kinetics and label-based fluorescence for high-contrast discrimination, validating performance with negative and positive human-serum samples.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/highly-sensitive-detection-of-anti-sars-cov-2-antibodies-in-human-serum-using-bloch-surface-wave-biosensor/463345/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/highly-sensitive-detection-of-anti-sars-cov-2-antibodies-in-human-serum-using-bloch-surface-wave-biosensor/463345.png","ImageObject",300,407,{"name":92,"@type":93},"Indoniesian Boy","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-31","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":29},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What antibody detection problem does this study address?","Question",{"text":112,"@type":113},"The study targets accurate, sensitive detection of anti-SARS-CoV-2 antibodies in human serum for advanced COVID-19 diagnostics and monitoring SARS-CoV-2 immunity.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the biosensor achieve dual-mode detection?",{"text":117,"@type":113},"It uses disposable one-dimensional photonic crystal biochips that support Bloch Surface Waves, integrated into a custom optical setup enabling label-free refractometry and label-based fluorescence.",{"name":119,"@type":110,"acceptedAnswer":120},"What performance was demonstrated on human serum samples?",{"text":121,"@type":113},"Fluorescence mode distinguished positive from negative samples at dilutions down to 1:10^4, with the optimal operating range centered around 1:10^3.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},463345,1790812622,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":29,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},962090760608,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Article  \nHighly Sensitive Detection of Anti-SARS-CoV-2 Antibodies in Human Serum Using Bloch Surface Wave Biosensor  \nAnastasiia Gaganina 1, Agostino Occhicone 1,2, Daniele Chiappetta 1,2, Paola Di Matteo 1, Norbert Danz 3, Matteo Allegretti 4, Peter Munzert 3, Chiara Mandoj 5, Francesco Michelotti 1 and Alberto Sinibaldi 1,2, *  \nAcademic Editor: Huizhong Xu  \nReceived: 15 November 2025  \nRevised: 6 December 2025  \nAccepted: 19 December 2025  \nPublished: 20 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 Department of Basic and Applied Science for Engineering, Sapienza University of Rome, Via A. Scarpa 16, 00161 Rome, Italy  \n2 Italian Institute of Technology (IIT), Center for Life Nano and Neuro Science, Viale Regina Elena 291,  \n00161 Rome, Italy  \n3 Fraunhofer Institute for Applied Optics and Precision Engineering IOF, Albert-Einstein-Str. 7, 07745 Jena, Germany  \n4 Translational Oncology Research Unit, IRCCS Regina Elena National Cancer Institute, Via Fermo Ognibene 23, 00144 Rome, Italy  \n5 Clinical Pathology Unit and Cancer Biobank, IRCCS Regina Elena National Cancer Institute, Via E. Chianesi  \n53, 00144 Rome, Italy  \n* Correspondence: [alberto.sinibaldi@uniroma1.it](alberto.sinibaldi@uniroma1.it)  \nAbstract  \nAccurate and sensitive antibody detection remains critical for advanced COVID-19 diagnostics and monitoring SARS-CoV-2 immunity. This study presents a highly sensitive technique for detecting anti-SARS-CoV-2 antibodies in human serum using an integrated photonic sensing platform. The platform utilizes disposable one-dimensional photonic crystal biochips engineered to sustain Bloch Surface Waves. The biochips are integrated into a custom-made optical set-up, which is capable of dual-mode detection: label-free refractometry and label-based fluorescence. Tests on human serum, including negative controls and positive samples from a recovered COVID-19 patient, confirmed the platform’s effective performance. In fluorescence mode, clear discrimination between positive and negative samples was achieved down to a 1:104 serum dilution, with an optimal operating range centered around 1:103 dilution. These results demonstrate the potential of the technique as a highly sensitive and versatile platform for antibody detection, with significant relevance for advanced COVID-19 diagnostics.  \nKeywords: biosensors; one-dimensional photonic crystals; Bloch surface waves; fluorescence; SARS-CoV-2  \n1. Introduction  \nThe global outbreak of Coronavirus Disease 2019 (COVID-19) [1], caused by Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), posed a global health crisis [2,3] . The urgent need for rapid and accurate testing technologies drove intense research. COVID- 19 thus served as a catalyst for the advancement of next-generation biosensing platforms. The widely accepted gold standard for detecting active infection is Reverse Transcription– Polymerase Chain Reaction (RT-PCR), which identifies the virus’s genetic material with exceptional sensitivity and specificity [4]. However, RT-PCR is limited by its high cost, long turnaround times, and dependence on centralized laboratory infrastructure, making it unsuitable for rapid, high-throughput point-of-care (POC) applications and large-scale serological surveillance [5,6]. In recent years, POC systems have gained widespread use compared to  \nconventional laboratory methods, enabling faster diagnostic results by allowing the detection of pathogenicity at the molecular level and identifying a wide range of disease agents [7,8]. Consequently, POC systems play a vital role in providing quick and accurate test results across various clinical settings [7]. These systems are especially valuable in emergency departments, where they contribute to improved patient care and infection control [9]. Moreover, the ex","cbCaitNAIcoMaSPL","https://ap.wps.com/l/cbCaitNAIcoMaSPL","pdf",4032903,11,"English","# Abstract\n# Introduction\n## Motivation for rapid, sensitive COVID-19 testing\n## Limitations of RT-PCR, ELISA, and LFAs\n## Dual-mode Bloch surface wave biosensor approach","[{\"question\":\"What antibody detection problem does this study address?\",\"answer\":\"The study targets accurate, sensitive detection of anti-SARS-CoV-2 antibodies in human serum for advanced COVID-19 diagnostics and monitoring SARS-CoV-2 immunity.\"},{\"question\":\"How does the biosensor achieve dual-mode detection?\",\"answer\":\"It uses disposable one-dimensional photonic crystal biochips that support Bloch Surface Waves, integrated into a custom optical setup enabling label-free refractometry and label-based fluorescence.\"},{\"question\":\"What performance was demonstrated on human serum samples?\",\"answer\":\"Fluorescence mode distinguished positive from negative samples at dilutions down to 1:10^4, with the optimal operating range centered around 1:10^3.\"}]","Highly Sensitive Detection of Anti-SARS-CoV-2 Antibodies in Human Serum Using Bloch Surface Wave Biosensor | PDF",1790766444,28,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/45a98cef4764f8c189aa5b3d5b86c81d.webp",983,1390,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/6035279d95db6d438f430fe515f29b99.webp",982,1388,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/807028ba9adb7e0aeca05ca22369155b.webp",981,1387,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/35466b90711c9f7c63677f96492bd3de.webp",980,1385]