[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-467040-105":59,"doc-detail-467040-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","highly-sensitive-capacitive-pressure-sensor-based-on-mwcntstio2pdms-with-a-microhemispherical-array-and-aptes-modified-interface","Highly Sensitive Capacitive Pressure Sensor Based on MWCNTs/TiO2/PDMS with a Microhemispherical Array and APTES-Modified Interface","","The rapid advancement of humanoid robotics has driven demand for flexible sensors capable of wide linear range detection. This work reports a capacitive flexible pressure sensor using a MWCNTs/TiO2/PDMS composite. A micro-hemispherical array is formed on the surface to reduce initial capacitance, while APTES-modified MWCNTs improve dispersion and interfacial bonding. Synergy between microstructures and CNT functionalization enhances sensing performance. With 2 wt% APTES, the sensor achieves dual-stage sensitivity over 0–95 kPa, fast 200 ms response, and stability over 2500 cycles for micro-pressure detection and wearable or array sensing.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/highly-sensitive-capacitive-pressure-sensor-based-on-mwcntstio2pdms-with-a-microhemispherical-array-and-aptes-modified-interface/467040/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/highly-sensitive-capacitive-pressure-sensor-based-on-mwcntstio2pdms-with-a-microhemispherical-array-and-aptes-modified-interface/467040.png","ImageObject",300,407,{"name":92,"@type":93},"Well Done","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-19","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",13,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What material system forms the capacitive pressure sensor in this study?","Question",{"text":113,"@type":114},"The sensor is built on a MWCNTs/TiO2/PDMS composite. A micro-hemispherical array is formed on its surface to tune the initial capacitance.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How does APTES modification affect the carbon nanotubes and sensor performance?",{"text":118,"@type":114},"Modified carbon nanotubes (F-MWCNTs) are prepared using APTES, which significantly enhances dispersion and interfacial bonding strength. This functionalization synergizes with microstructures to improve sensing performance.",{"name":120,"@type":111,"acceptedAnswer":121},"What sensing range and key performance metrics are reported for the 2 wt% APTES device?",{"text":122,"@type":114},"The 2 wt% APTES-modified sensor shows dual-stage sensitivity across 0–95 kPa, a response time of 200 milliseconds, and stability over 2500 cyclic loadings.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},467040,1790812623,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},5909892210082,"https://ap-avatar.wpscdn.com/avatar/56001069da27c9f41e8?x-image-process=image/resize,m_fixed,w_180,h_180&k=1789614185077863061","Article  \nHighly Sensitive Capacitive Pressure Sensor Based on MWCNTs/TiO2/PDMS with a Microhemispherical Array and APTES-Modified Interface  \nYijin Ouyang 1,2, Jianyong Lei 2,3, Shuge Li 2,4, Guotian He 2,5 and Songxiying He 5, *  \nAcademic Editor: Tsuyoshi Michinobu  \nReceived: 6 November 2025  \nRevised: 16 December 2025  \nAccepted: 17 December 2025  \nPublished: 20 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 School of Mechanical Engineering, Chongqing University of Technology, Chongqing 400054, China; [jack_sparrow00@163.com](jack_sparrow00@163.com)  \n2 Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China; [leijianyongn@126.com](leijianyongn@126.com) (J.L.); [lishuge@cqcet.edu.cn](lishuge@cqcet.edu.cn) (S.L.); [heguotian@cigit.ac.cn](heguotian@cigit.ac.cn) (G.H.)  \n3 Chongqing Institute of the University of Chinese Academy of Sciences, Chongqing University, Chongqing 400044, China  \n4 School of Smart Health, Chongqing Polytechnic University of Electronic Technology, Chongqing 401331, China  \n5 Chongqing Luban Robotics Technology Research Institute Co., Ltd., Chongqing 400799, China  \n* [Correspondence: hesongwwww@126.com](Correspondence: hesongwwww@126.com)  \nAbstract  \nThe rapid advancement of humanoid robotics has spurred researchers’ interest in flexible sensors for wide linear range detection. In response, we report a capacitive flexible pressure sensor based on a multi-walled carbon nanotubes/titanium dioxide/polydimethylsiloxane (MWCNTs/TiO 2/PDMS) composite. A micro-hemispherical structure array formed on the composite surface via a templating method reduces the initial capacitance value. Modified carbon nanotubes (F-MWCNTs) were prepared using 2 wt%, 5 wt% and 10 wt%γ-aminopropyltriethoxysilane (APTES), significantly enhancing dispersion and interfacial bonding strength. The synergistic effect of microstructures and MWCNTs surface functionalization further enhances sensing performance. The F-MWCNTs/TiO2 /PDMS pressure sensor modified with 2 wt% APTES exhibits outstanding sensing capabilities: it demonstrates dual-stage sensitivity across a broad linear range of 0–95 kPa (0–13 kPa segment: 1.89 ± 0.49 kPa−1; 13–95 kPa segment: 7.08 ± 0.63 kPa−1), with a response time of 200 milliseconds, maintaining stability over 2500 cyclic loadings. In practical application exploration, this sensor has demonstrated strong adaptability, confirming its significant potential in micro-pressure detection, wearable electronics, and array sensing applications.  \nKeywords: composites; flexible sensors; surface modification; carbon nanotubes; microstructure  \n1. Introduction  \nRecently, the rapid development of humanoid robotics has drawn more attention from researchers to flexible pressure sensors. The core function of a pressure sensor, as a detection device, is to convert an applied physical pressure signal into a measurable electrical signal output. According to the different sensing principles, the main types include piezoresistive, capacitive, piezoelectric, triboelectric and inductive. Among them, flexible capacitive pressure sensors are characterized by low power consumption, fast response, small drift, and high linearity and therefore have a promising future in automotives [1,2], robotics [3,4], healthcare [5,6], aerospace [7,8] and wearable electronic devices [9,10] .  \nCarbon nanotubes (CNTs) are nanoscale tubular materials formed by carbon atoms through sp2 hybridization. Due to their exceptional strength and outstanding electrical conductivity, they have been widely adopted in the field of flexible pressure sensors [11,12] . However, in the face of complex application scenarios, the properties of CNTs by themselves are usually unable to meet the variable conditions of use. Therefore, it has been","cbCaihTJCcySnwp6","https://ap.wps.com/l/cbCaihTJCcySnwp6","pdf",10314221,15,"English","# Abstract\n# Keywords\n# Introduction","[{\"question\":\"What material system forms the capacitive pressure sensor in this study?\",\"answer\":\"The sensor is built on a MWCNTs/TiO2/PDMS composite. A micro-hemispherical array is formed on its surface to tune the initial capacitance.\"},{\"question\":\"How does APTES modification affect the carbon nanotubes and sensor performance?\",\"answer\":\"Modified carbon nanotubes (F-MWCNTs) are prepared using APTES, which significantly enhances dispersion and interfacial bonding strength. This functionalization synergizes with microstructures to improve sensing performance.\"},{\"question\":\"What sensing range and key performance metrics are reported for the 2 wt% APTES device?\",\"answer\":\"The 2 wt% APTES-modified sensor shows dual-stage sensitivity across 0–95 kPa, a response time of 200 milliseconds, and stability over 2500 cyclic loadings.\"}]","Highly Sensitive Capacitive Pressure Sensor Based on MWCNTs/TiO2/PDMS with a Microhemispherical Array and APTES-Modified Interface | PDF",1790772228,38,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/dabe910fdbafde03df90a5a8dc4896a9.webp",983,1390,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/e3546e388938ef8976da7a98659aebce.webp",982,1388,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/142dd6529bd0d26241d56ed6f932985c.webp",981,1387,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/8e2f0ed6236658909c8f3478c65681fd.webp",980,1385]