[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-374266-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-374266-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","highly-sensitive-cancer-detection-using-an-open-d-channel-pcf-based-spr-biosensor","Highly sensitive cancer detection using an open D-channel PCF-based SPR biosensor","","Label-free surface plasmon resonance (SPR) is used for detecting cancer cells, and this study proposes a photonic crystal fiber (PCF) sensor with an open D-channel. The structure integrates gold (Au) and titanium dioxide (TiO2) as the plasmonic material to reduce the gap between the fiber core and Au, while TiO2 between Au and the silica substrate improves adhesion and structural robustness. Finite element simulations in COMSOL quantify refractive-index sensing for analytes with RI 1.25–1.43, including six cancer cell types (1.36–1.401), reporting enhanced sensitivity and strong performance metrics versus existing biosensors.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/highly-sensitive-cancer-detection-using-an-open-d-channel-pcf-based-spr-biosensor/374266/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/highly-sensitive-cancer-detection-using-an-open-d-channel-pcf-based-spr-biosensor/374266.png","ImageObject",300,407,{"name":42,"@type":43},"Miles","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-23","2026-09-23",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",28,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the main sensing principle behind the proposed biosensor?","Question",{"text":63,"@type":64},"The sensor is based on label-free surface plasmon resonance (SPR), where optical response changes track variations in the analyte’s refractive index.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How does the open D-channel PCF design improve sensor performance?",{"text":68,"@type":64},"The design reduces the gap between the fiber core and the gold layer, and introducing TiO2 between gold and the silica substrate improves adhesion and overall structural robustness.",{"name":70,"@type":61,"acceptedAnswer":71},"What refractive index range and cancer cell types are used for evaluation?",{"text":72,"@type":64},"The study targets RI values from 1.25 to 1.43 overall, with RI variations from 1.36 to 1.401 examined across six cancer cell types.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},374266,1790241163,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":97,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":140,"language":141,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":12,"update_tm":145,"read_time":146,"preview_page_count":26,"preview_urls":147},13056703019404,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","[www. nature.com/scientificreports](www. nature.com/scientificreports)  \nOPEN  \nHighly sensitive cancer detection using an open D-channel PCFbased SPR biosensor  \nMahla Ashrafian1, Saeed Olyaee1,2􀀍 & Mahmood Seifouri2  \nSurface plasmon resonance (SPR) is a technique utilized for the label-free detection of cancer cells. In this analysis, we introduce a photonic crystal fiber (PCF) designed with an open D-channel, featuring a layer of gold (Au) and titanium dioxide (TiO2) as the plasmonic material. This effectively reduces the gap between the fiber core and the gold layer, resulting in improved performance. Additionally, incorporating TiO2 between the gold and the silica substrate enhances their adhesion and contributes to a more robust structure. We conducted a comprehensive numerical analysis of the suggested biosensor utilizing the finite element method (FEM) integrated with perfectly matched layers (PML) within the COMSOL Multiphysics simulation tool. The design of this sensor is specifically intended for the detection of molecules with a refractive index (RI) varying from 1.25 to 1.43, achieving an impressive peak spectral sensitivity of 47,000 nm/RIU. For this purpose, we investigated RI values from  \n1.36 to 1.401 concerning six different cancer cell types. The highest spectral sensitivity is 5214.285 nm/ RIU, while the amplitude sensitivity is-1481.1 RIU− 1, which has been recorded for MCF-7 and HeLa cells. This proposed sensor shows improved amplitude sensitivity, signal-to-noise ratio (SNR), full width at half maximum (FWHM), figure of merit (FOM), and detection limit (DL) compared to existing biosensors, highlighting its potential for biosensing applications. Additionally, it is significant that according to the results, HeLa cells have a maximum resolution of 1.19 × 10− 5 RIU and a FOM of 350 RIU− 1 .  \nKeywords Photonic crystal fiber (PCF), Biosensor, Surface plasmon resonance (SPR), Microchannel, Cancerous cells  \nIn recent decades, cancer research has gained significant attention due to the disease’s severity and treatment challenges. Cancer occurs when healthy cells undergo changes that lead to the formation of cancerous cells. Biosensors enable quick cancer diagnosis by detecting specific chemicals in biological samples. They identify molecules like antibodies or enzymes, allowing for early detection of cancer cells, which is crucial for improving treatment outcomes1–3. Biosensors are categorized into three primary types based on their bio-transducer; Acoustic, Optical, and Thermal biosensors. In 1962, Clark and Lyons pioneered the optical sensing system, leading to various applications for optical sensors. Sensors convert biological data into optical signals by tracking light property changes when interacting with substances. Many optical sensors depend on spectral features, such as a distinct peak or slope, arising from resonance. Variations in the refractive index (RI) lead to intensity or wavelength shifts, which are used to monitor changes in the analyte’s RI4,5.  \nOptical biosensors can be classified on two criteria; Label and Label-free. Detection usually requires labels like enzymes or fluorescent markers that bind to the target analyte. The measurement signal depends on the amounts of target analytes and labels. Various labeling techniques include electrochemically active probes, chemiluminescence, and fluorescent labeling. However, this process can be costly, time-consuming, and may interfere with receptor-analyte interactions6. An alternative diagnostic method that is highly recommended is label-free detection. This technique eliminates labels and encompasses methods such as localized surface plasmon resonance (LSPR), mass spectrometry, microcantilevers, and surface plasmon resonance (SPR) . These techniques detect analytes based on intrinsic physical characteristics like charge, dielectric constant, refractive index changes, and size. Sensors that use SPR allow for quick and accurate detection of va","cbCaidMFowJqoy56","https://ap.wps.com/l/cbCaidMFowJqoy56","pdf",5856110,17,"English","# Introduction\n## Cancer diagnosis and biosensors\n## Optical biosensors: label vs label-free\n## SPR biosensors and photonic crystal fibers\n# Sensor design and numerical analysis\n## Open D-channel PCF structure\n## Gold–TiO2 plasmonic configuration\n## FEM simulation using COMSOL Multiphysics\n# Performance results\n## Refractive index range and cancer cell types\n## Sensitivity, SNR, FWHM, FOM, and detection limit","[{\"question\":\"What is the main sensing principle behind the proposed biosensor?\",\"answer\":\"The sensor is based on label-free surface plasmon resonance (SPR), where optical response changes track variations in the analyte’s refractive index.\"},{\"question\":\"How does the open D-channel PCF design improve sensor performance?\",\"answer\":\"The design reduces the gap between the fiber core and the gold layer, and introducing TiO2 between gold and the silica substrate improves adhesion and overall structural robustness.\"},{\"question\":\"What refractive index range and cancer cell types are used for evaluation?\",\"answer\":\"The study targets RI values from 1.25 to 1.43 overall, with RI variations from 1.36 to 1.401 examined across six cancer cell types.\"}]","Highly sensitive cancer detection using an open D-channel PCF-based SPR biosensor | PDF",1790201380,43,[148,152],{"page_no":22,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-08/f026532950b35a6b8ef6c82f9c4bcca7.webp",983,1291,{"page_no":26,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-08/1bdd67ab775e1ee9512b724ea605354b.webp",982,1290]