[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-458690-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-458690-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","high-throughput-fabrication-of-zero-mode-waveguide-nanoaperture-arrays-with-sol-gel-nanoimprint-lithography-for-enhanced-single-molecule-fluorescence-detection","High-Throughput Fabrication of Zero-Mode Waveguide Nanoaperture Arrays with Sol-Gel Nanoimprint Lithography for Enhanced Single Molecule Fluorescence Detection","","Zero-mode waveguides (ZMWs) use subwavelength metallic nanoapertures to enhance single-molecule fluorescence at micromolar concentrations, surpassing diffraction-limited confocal performance. A scalable, cost-effective fabrication strategy is presented by combining sol-gel nanoimprint lithography with hydrofluoric acid (HF) vapor-phase etching to enable parallel production and replication of ZMW arrays. Single-molecule fluorescence experiments validate optical performance via burst analysis, FCS, and smFRET, showing up to 8× brightness enhancement, sub-millisecond timing, and broadband visible operation.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/high-throughput-fabrication-of-zero-mode-waveguide-nanoaperture-arrays-with-sol-gel-nanoimprint-lithography-for-enhanced-single-molecule-fluorescence-detection/458690/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/high-throughput-fabrication-of-zero-mode-waveguide-nanoaperture-arrays-with-sol-gel-nanoimprint-lithography-for-enhanced-single-molecule-fluorescence-detection/458690.png","ImageObject",300,407,{"name":42,"@type":43},"Aran","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-04","2026-09-30",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",8,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What problem do zero-mode waveguides address in single-molecule fluorescence detection?","Question",{"text":63,"@type":64},"They reduce the effective detection volume below the diffraction limit, improving fluorescence brightness and temporal resolution while enabling operation at micromolar concentrations.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How does the presented fabrication method produce ZMW nanoaperture arrays?",{"text":68,"@type":64},"It combines sol-gel nanoimprint lithography with HF vapor-phase etching to allow parallel fabrication and massive replication of nanoapertures without expensive equipment.",{"name":70,"@type":61,"acceptedAnswer":71},"Which experimental analyses were used to validate the optical performance of the fabricated ZMWs?",{"text":72,"@type":64},"The study validates performance using burst analysis, fluorescence correlation spectroscopy (FCS), and single-molecule Förster resonance energy transfer (smFRET).","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},458690,1790818699,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":55,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":33,"preview_urls":146},137455076865,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","RESEARCH ARTICLE  \n[www.small-journal.com](www.small-journal.com)  \nHigh-Throughput Fabrication of Zero-Mode Waveguide Nanoaperture Arrays with Sol-Gel Nanoimprint Lithography for Enhanced Single Molecule Fluorescence Detection  \nHamza Khelidj, Anthony Gourdin, Igor Ozerov, Antonin Moreau, Badre Kerzabi, David Grosso, and Jérôme Wenger*  \nZero-mode waveguides (ZMWs) are subwavelength metallic nanoapertures enabling enhanced single-molecule ﬂuorescence detection at micromolar concentrations in conditions far beyond the diﬀraction-limited capabilities of confocal microscopes. However, their widespread use remains limited by the complexity and cost of the nanofabrication techniques, such as focused ion beam and electron-beam lithography. Here, a scalable, cost-eﬀective, and highthroughput method for fabricating high-performance ZMW arrays is presented, which combining sol-gel nanoimprint lithography (NIL) with hydroﬂuoric acid (HF) vapor-phase etching. This approach enables the parallel fabrication and massive replication of ZMW nanoapertures with attoliter volumes, without requiring expensive equipment. The optical performance of the resulting ZMWsis validated through a series of single-molecule ﬂuorescence experiments, including burst analysis, ﬂuorescence correlation spectroscopy (FCS), and single-molecule Förster resonance energy transfer (smFRET). The ZMW nanoapertures demonstrate up to 8× ﬂuorescence brightness enhancement, sub-millisecond temporal resolution, and broadband spectral operation across the visible range. This method represents a signiﬁcant advance in making nanophotonic devices more accessible, paving the way for a broader adoption of ZMWs in single-molecule biosensing and integrated nanophotonic systems.  \nunderlying biological processes. [1–7] However, single-molecule detection remains predominantly performed on confocal ﬂuorescence microscopes constrained by diﬀraction, which in turn imposes two major fundamental limits. [8–10] First, due to the size mismatch between the dimension of a single quantum emitter and the wavelength of light, the light-matter interaction at the nanoscale is ineﬃcient, leading to a weak detected ﬂuorescence brightness of a few tens of thousands of photons per second. [11,12] This low signal not only challenges the detection of single-molecule events but also limits the temporal resolution on diﬀraction-limited microscopes,[13–15] typically in the millisecond range in order to collect enough photons per time bin. The second major limit concerns the detection volume: with a typical confocal volume of 1 fL (10−15 L), diluted concentrations in the pico to nanomolar range are required to isolate a single molecule on a diﬀraction-limited microscope. Such conditions are incompatible with most physiological and biochemical  \n1. Introduction  \nSingle-molecule ﬂuorescence techniques have become essential tools in modern biophysics to reveal the molecular mechanisms  \nreactions, which occur at micromolar to millimolar concentrations. [16–18]  \nBoth limitations of single-molecule ﬂuorescence detection can be simultaneously addressed by introducing zero-mode  \nH. Khelidj, A. Moreau, J. Wenger Aix Marseille Univ  \nCNRS Centrale Med Institut Fresnel AMUTech  \nMarseille 13013, France  \nE-mail: jerome.wenger@fresnel.fr  \nThe ORCID identiﬁcation number(s) for the author(s) of this article can be found under [https://doi.org/10.1002/smll.202510587](https://doi.org/10.1002/smll.202510587)  \n© 2025 The Author(s) . Small published by Wiley-VCH GmbH. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.  \nDOI: 10.1002/smll.202510587  \nA. Gourdin, B. Kerzabi, D. Grosso Solnil  \n163 Avenue de Luminy, Marseille 13009, France  \nI. Ozerov, D. Grosso Aix-Marseille Univ CNRS  \nCINaM AMUTech  \nCampus de Luminy Marseille 13288, France  \nSmall 2026, 22, e10587 e10587 ","cbCainMMIiLMaAnD","https://ap.wps.com/l/cbCainMMIiLMaAnD","pdf",5970091,11,"English","# Introduction\n## Background: limits of confocal single-molecule fluorescence\n## Zero-mode waveguides and advantages\n## Motivation: fabrication complexity and cost\n# Methods and results\n## Scalable fabrication using sol-gel nanoimprint lithography and HF vapor-phase etching\n## Validation using burst analysis, FCS, and smFRET","[{\"question\":\"What problem do zero-mode waveguides address in single-molecule fluorescence detection?\",\"answer\":\"They reduce the effective detection volume below the diffraction limit, improving fluorescence brightness and temporal resolution while enabling operation at micromolar concentrations.\"},{\"question\":\"How does the presented fabrication method produce ZMW nanoaperture arrays?\",\"answer\":\"It combines sol-gel nanoimprint lithography with HF vapor-phase etching to allow parallel fabrication and massive replication of nanoapertures without expensive equipment.\"},{\"question\":\"Which experimental analyses were used to validate the optical performance of the fabricated ZMWs?\",\"answer\":\"The study validates performance using burst analysis, fluorescence correlation spectroscopy (FCS), and single-molecule Förster resonance energy transfer (smFRET).\"}]","High-Throughput Fabrication of Zero-Mode Waveguide Nanoaperture Arrays with Sol-Gel Nanoimprint Lithography for Enhanced Single Molecule Fluorescence Detection | PDF",1790754091,28,[147,151,155,159],{"page_no":22,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/7946faa7b8273915d0f9c919d668f81d.webp",983,1291,{"page_no":26,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/536de7d937195a95f2ab0a3d59222ba8.webp",982,1290,{"page_no":30,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/b24cf898a241c0f3cd516a63bd255406.webp",981,1289,{"page_no":33,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/f1e8bbf7a07c7f188d3f5102fe066386.webp",980,1287]