[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-515683-105":59,"doc-detail-515683-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","high-performance-ultrasound-needle-transducer-based-on-modified-pmn-pt-ceramic-with-ultrahigh-clamped-dielectric-permittivity","High-Performance Ultrasound Needle Transducer Based on Modiﬁed PMN-PT Ceramic With Ultrahigh Clamped Dielectric Permittivity","","A modified Pb(Mg 1/3Nb2/3)O3-PbTiO3 (PMN-PT) polycrystalline ceramic with ultrahigh relative clamped dielectric permittivity (εS/ε 0 = 3500) and strong piezoelectric properties (d33 = 1200 pC/N, kt = 0.55) was used to fabricate high-frequency miniature ultrasound transducers. A 39-MHz needle transducer with a 0.4 mm × 0.4 mm aperture was designed and characterized. The fabricated transducer achieved an electromechanical coupling factor kt of 0.55, 80% bandwidth at −6 dB, and low insertion loss of −13 dB, showing strong imaging in wire phantom and porcine eyeball studies, with performance superior to other miniature needle transducers.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/high-performance-ultrasound-needle-transducer-based-on-modified-pmn-pt-ceramic-with-ultrahigh-clamped-dielectric-permittivity/515683/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/high-performance-ultrasound-needle-transducer-based-on-modified-pmn-pt-ceramic-with-ultrahigh-clamped-dielectric-permittivity/515683.png","ImageObject",300,407,{"name":92,"@type":93},"Ivy","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-16","2026-10-06",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What material and key dielectric property were used for the transducer?","Question",{"text":113,"@type":114},"The transducer was fabricated using modified PMN-PT polycrystalline ceramic with ultrahigh relative clamped dielectric permittivity, εS/ε0 = 3500.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What were the main specifications of the needle transducer design?",{"text":118,"@type":114},"A 39-MHz high-frequency ultrasound needle transducer was designed with a miniature aperture of 0.4 mm × 0.4 mm.",{"name":120,"@type":111,"acceptedAnswer":121},"How did the transducer perform in phantom and biological imaging studies?",{"text":122,"@type":114},"A wire phantom and porcine eyeball imaging study showed good imaging capability, and the transducer performance was reported as superior to other needle transducers with similar miniature apertures.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},515683,1791402402,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":39,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":46,"preview_page_count":19,"preview_urls":145},549758252649,"https://ap-avatar.wpscdn.com/avatar/8000253669c5317157?_k=1778319167496531819","High-Performance Ultrasound Needle Transducer Based on Modiﬁed PMN-PT Ceramic With Ultrahigh Clamped Dielectric Permittivity  \nZhiqiang Zhang, Fei Li, Ruimin Chen, Tianfu Zhang, Xiaodong Cao, Shujun Zhang, Senior Member, IEEE , Thomas R. Shrout, Hairong Zheng, K. Kirk Shung, Life Fellow, IEEE, Mark S. Humayun, Weibao Qiu, Senior Member, IEEE, and Qifa Zhou  \nAbstract—A modiﬁed Pb(Mg 1/3Nb2/3)O3-PbTiO3 (PMN-PT) polycrystalline ceramic with ultrahigh relative clamped dielectric permittivity (εS/ε 0 = 3500) and high piezoelectric properties (d33 = 1200 pC/N, kt = 0.55) was used to fabricate high-frequency miniature ultrasound transducers. A 39-MHz high-frequency ultrasound needle transducer with a miniature aperture of 0.4 mm × 0.4 mm was designed and successfully characterized. The fabricated needle transducer had an  \nManuscript received July 26, 2017; accepted November 24, 2017 . Date of publication December 4, 2017; date of current version January 26, 2018 . This work was supported in part by the National Science Foundation of China under Grant 81527901, Grant 61571431, Grant 11325420, and Grant 11534013, in part by the National Basic Research Program of China under Grant 2015CB755500, in part by CAS Research Projects under Grant Y650311C31, Grant QYZDB-SSW-JSC018, and Grant YJKYYQ20170065, in part by the Guangdong Innovative and Entrepreneurial Research Team Program under Grant 2013S046, in part by the Natural Science Foundation of Guangdong Province under Grant 2015A030306018, Grant 2014A030313686, Grant 2014A030312006, and Grant 2014B030301013, in part by the Shenzhen Peacock Plan under Grant 20130409162728468, and in part by the Shenzhen Foundation under Grant JCYJ20170413164936017 . (Corresponding authors: Weibao Qiu; Qifa Zhou.)  \nZ. Zhang is with the Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China, with the USC Roski Eye Institute, University of Southern California, Los Angeles, CA 90033 USA, with the USC Institute for Biomedical Therapeutics, University of Southern California, Los Angeles, CA  \n90033 USA, and also with the School of Materials Science and Engineering, South China University of Technology, Guangzhou 510641, China.  \nF. Li, S. Zhang, and T. R. Shrout are with the Department of Materials Science and Engineering, Pennsylvania State University, University Park, PA  \n16802 USA.  \nR. Chen, T. Zhang, and K. K. Shung are with the NIH Resource on Medical Ultrasonic Transducer Technology, Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089 USA.  \nX. Cao is with the School of Materials Science and Engineering, South China University of Technology, Guangzhou 510641, China.  \nH. Zheng and W. Qiu are with the Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China ([e-mail: wb.qiu@siat.ac.cn](e-mail: wb.qiu@siat.ac.cn)).  \nM. S. Humayun is with the USC Roski Eye Institute, University of Southern California, Los Angeles, CA 90033 USA, with the USC Institute for Biomedical Therapeutics, University of Southern California, Los Angeles, CA 90033 USA, and also with the Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089 USA.  \nQ. Zhou is with the USC Roski Eye Institute, University of Southern California, Los Angeles, CA 90033 USA, with the USC Institute for Biomedical Therapeutics, University of Southern California, Los Angeles, CA 90033 USA, and also with the NIH Resource on Medical Ultrasonic Transducer Technology, Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089 USA (e-mail: [qifazhou@usc.edu](qifazhou@usc.edu)).  \nDigital Object Identiﬁer 10.1109/TUFFC.2017.2778738  \nelectromechanical coupling factor kt of 0.55, large bandwidth of 80% at −6 dB, and low insertion loss of −13 dB. A wire phantom and porcine eye","cbCaig138KOGuyt6","https://ap.wps.com/l/cbCaig138KOGuyt6","pdf",2327169,"English","# Abstract\n# Index Terms\n# I. Introduction","[{\"question\":\"What material and key dielectric property were used for the transducer?\",\"answer\":\"The transducer was fabricated using modified PMN-PT polycrystalline ceramic with ultrahigh relative clamped dielectric permittivity, εS/ε0 = 3500.\"},{\"question\":\"What were the main specifications of the needle transducer design?\",\"answer\":\"A 39-MHz high-frequency ultrasound needle transducer was designed with a miniature aperture of 0.4 mm × 0.4 mm.\"},{\"question\":\"How did the transducer perform in phantom and biological imaging studies?\",\"answer\":\"A wire phantom and porcine eyeball imaging study showed good imaging capability, and the transducer performance was reported as superior to other needle transducers with similar miniature apertures.\"}]","High-Performance Ultrasound Needle Transducer Based on Modiﬁed PMN-PT Ceramic With Ultrahigh Clamped Dielectric Permittivity | PDF",1791321167,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/061c67b11387bce299172bd598ec5b89.webp",983,1272,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/7187777246905e4c76f013f448bb61eb.webp",982,1270,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/de08137661d10214348f9d8f3c8ac4de.webp",981,1269,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/e0d1ed4e824c9677d759aa58249013f4.webp",980,1268]