[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-664696-105":59,"doc-detail-664696-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","heavy-duty-sealed-connector-series-hdscs-2-18-positions-electrical-performance-and-quality-requirements","Heavy Duty Sealed Connector Series (HDSCS) - 2-18 Positions - Electrical Performance and Quality Requirements","","The specification defines the performance, tests, and quality requirements for electrical heavy-duty sealed connectors with 2 to 18 positions for various AMP MCP contact systems and locking slides. It addresses scope, qualification, applicable documents, and binding precedence rules between the specification, product drawings, and referenced documents. It also outlines design and construction, materials, ratings, and detailed requirements and procedures, including quality assurance and testing activities such as qualification, requalification, acceptance, and quality conformance inspection.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/heavy-duty-sealed-connector-series-hdscs-2-18-positions-electrical-performance-and-quality-requirements/664696/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/heavy-duty-sealed-connector-series-hdscs-2-18-positions-electrical-performance-and-quality-requirements/664696.png","ImageObject",300,407,{"name":92,"@type":93},"Supernature","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What does this specification cover for HDSCS connectors?","Question",{"text":112,"@type":113},"It covers electrical heavy-duty sealed connector performance, tests, and quality requirements for 2 to 18 positions for several AMP MCP contact systems, including qualification-related testing and quality assurance provisions.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which documents control when there is a conflict?",{"text":117,"@type":113},"In cases of conflict between this specification and the product drawing or referenced documents, this specification takes precedence.",{"name":119,"@type":110,"acceptedAnswer":120},"What types of testing and quality assurance activities are included?",{"text":121,"@type":113},"The specification includes qualification testing, requalification testing, acceptance, and quality conformance inspection, with inspections performed according to applicable inspection plans and product drawings.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},664696,1793267524,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":26},962093270004,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Heavy Duty Sealed Connector Series (HDSCS),  \n2 to 18 positions, for AMP MCP Contact Systems  \nHoch beanspruchbare Steckverbinder-Serie, gedichtet  \n(HDSCS) ,  \n2 bis 18polig, für AMP MCP Kontaktsysteme  \n\n|  |  |  |  | DR\u003Cbr>D. Bischoff 12OCT2006 |  | TE Connectivity\u003Cbr>Ampèrestraße 12-14 D-64625 Bensheim GERMANY |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |\n|  |  |  |  | CHK\u003Cbr>J. Granzow\u003Cbr>16 OCT2006 |  |  |  |  |\n| E | Text 3.3 A voltage\u003Cbr>changed and remarks added.\u003Cbr>Group D at 3.4 added | S. Gilch | 06OKT2017 |  |  |  |  |  |\n| D | Remarks on page 6 and 7 added | S. Gilch | 03MAY2016 |  |  |  |  |  |\n| C | Adding application [temp. at](temp. at) ice water shock test (3.5.21) | S. Gilch | 01OCT2015 | APP\u003Cbr>Ch. Eberwein 26JAN2009 |  | NO\u003Cbr>108-94020 | REV\u003Cbr>E | LOC\u003Cbr>AI |\n| B1 | - | D. Bischoff | 22APR2013 |  |  |  |  |  |\n| B | - | J. Granzow | 10FEB2012 |  |  |  |  |  |\n| LTR | REVISION\u003Cbr>RECORD | APP | DATE | PAGE\u003Cbr>1 OF 24 | Titel\u003Cbr>Heavy Duty Sealed Connector Series Hoch beanspruchbare Steckverbinder-Serie, gedichtet |  |  |  |\n\nCONTENTS INHALT  \n1. SCOPE  \n1.1 Content  \n1.2 Qualification  \n2. APPLICABLE DOCUMENTS  \n2.1 TE Connectivity (TE) Documents  \n2.2 General Documents  \n3. REQUIREMENTS  \n3.1 Design and Construction  \n3.2 Materials  \n3.3 Ratings  \n3.4 Performance and Test Description  \n3.5 Requirements and Procedures  \n4. QUALITY ASSURANCE PROVISIONS  \n4.1 Qualification Testing  \n4.2 Requalification Testing  \n4.3 Acceptance  \n4.4 Quality Conformance Inspection  \n1. ANWENDUNGSBEREICH  \n1.1 Inhalt  \n1.2 Qualifikation  \n2. ANWENDBARE UNTERLAGEN  \n2.1 TE Connectivity (TE) Unterlagen  \n2.2 Allgemeine Unterlagen  \n3. ANFORDERUNGEN  \n3.1 Entwurf und Konstruktion  \n3.2 Werkstoffe  \n3.3 Technische Daten  \n3.4 Leistungsmerkmale und Testbeschreibung  \n3.5 Anforderungen und Prüfungen  \n4. QUALITÄTSSICHERUNGSMASSNAHMEN  \n4.1 Qualifikationsprüfungen  \n4.2 Requalifikationsprüfung  \n4.3 Abnahme  \n4.4 Prüfung der Qualitätskonformität  \n1 SCOPE  \n1.1 Content  \nThis specification covers the performance, tests and quality requirements of electrical heavy-duty connectors , 2 to 18 positions for several AMP MCP contacts. These connectors may be mounted directly to the combustion engine or to the gear box and by that exposed high thermal and mechanical stress.  \n1.2 Qualification  \nWhen tests are performed, the following specified specifications and standards shall be used. All inspections shall be performed using the applicable inspection plan and product drawing.  \n2 APPLICABLE DOCUMENTS  \nThe following documents are part of this specification to the extent specified herein. In the events of conflict between the requirements of this specification and the product drawing or of conflict between the requirements of this specification and the referenced documents, this specification shall take precedence.  \n1 ANWENDUNGSBEREICH  \n1.1 Inhalt  \nDiese Spezifikation beschreibt die Eigenschaften, Tests und Qualitätsanforderungen für die elektrischen, hoch beanspruchbaren Steckverbinder, 2 bis 18polig, für diverse AMP MCP Kontakte und Schieberverriegelung. Diese Steckverbindungen werden z. B. direkt am Verbrennungsmotor bzw. Getriebeeingesetzt und sind dadurch besonders hohenthermischen und dynamischen Beanspruchungen ausgesetzt.  \n1.2 Qualifikation  \nBei der Prüfung der genannten Produkte sind die nachfolgend aufgeführten Richtlinien und Normen zu verwenden. Alle Prüfungen müssen nach den zugehörigen Prüfplänen und Produktzeichnungen durchgeführt werden.  \n2 ANWENDBARE UNTERLAGEN  \nDie nachfolgend genannten Unterlagen, sofern darauf verwiesen wird, sind Teil dieser Spezifikation. Im Falle des Widerspruches zwischen dieser Spezifikation und der Produktzeichnung oder des Widerspruches zwischen dieser Spezifikation und den aufgeführten Unterlagen hat diese Spezifikation Vorrang.  \n2.1 TE Connectivity (TE) Documents  \nA 109-1: General Requirements for Test Specif","cbCaihQ3FyCEWDwK","https://ap.wps.com/l/cbCaihQ3FyCEWDwK","pdf",1082603,24,"English","# SCOPE\n## Content\n## Qualification\n# APPLICABLE DOCUMENTS\n## TE Connectivity (TE) Documents\n## General Documents\n# REQUIREMENTS\n## Design and Construction\n## Materials\n## Ratings\n## Performance and Test Description\n## Requirements and Procedures\n# QUALITY ASSURANCE PROVISIONS\n## Qualification Testing\n## Requalification Testing\n## Acceptance\n## Quality Conformance Inspection","[{\"question\":\"What does this specification cover for HDSCS connectors?\",\"answer\":\"It covers electrical heavy-duty sealed connector performance, tests, and quality requirements for 2 to 18 positions for several AMP MCP contact systems, including qualification-related testing and quality assurance provisions.\"},{\"question\":\"Which documents control when there is a conflict?\",\"answer\":\"In cases of conflict between this specification and the product drawing or referenced documents, this specification takes precedence.\"},{\"question\":\"What types of testing and quality assurance activities are included?\",\"answer\":\"The specification includes qualification testing, requalification testing, acceptance, and quality conformance inspection, with inspections performed according to applicable inspection plans and product drawings.\"}]","Heavy Duty Sealed Connector Series (HDSCS) - 2-18 Positions - Electrical Performance and Quality Requirements | PDF"]